Serviceline Industrial Sensors
Serviceline Explosion Protection

Retroreflective sensor RLK29-55/25/116-Set

RLK29-55/25/116-Set
  • Robust, compact photoelectric sensor for single-beam gate protection
  • Not sensitive to ambient light, even with energy saving lamps
  • Tamper-proof, no operating controls
  • Version for universal voltages
  • Relay output
  • Version with accessories in scope of delivery

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  RLK29-55/25/116-Set

Product Description
Robust, compact, long range photoelectric sensors for detecting people, objects and vehicles
General specifications
Effective detection range0 ... 12 m
Reflector distance0.04 ... 12 m
Threshold detection range14 m
Reference targetH85-2 reflector
Light sourceLED
Light typemodulated visible red light , 640 nm
Diameter of the light spotapprox. 35 mm at a distance of 12 m
Opening angle± 1 °
Ambient light limit90000 Lux
Accessories providedreflector C110-2 , Mounting bracket with mounting materials
Functional safety related parameters
MTTFd1460 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
Function indicatorLED red
illuminates: when beam is free
flashes: when level falls below operating reserve
off: when beam is interrupted
Electrical specifications
Operating voltage24 ... 230 V AC/DC
Ripple10 %
No-load supply current≤ 8.5 mA
Power consumption0.2 W at 24 V DC , 1.8 W at 230 V AC 3 VA
Output
Switching typelight-on
Signal outputRelay, 1 alternator
Switching voltage230 V AC
Switching currentmax. 2 A
Switching frequency7 Hz
Response time50 ms
Conformity
Product standardEN 60947-5-2
Approvals and certificates
CE conformityyes
EAC conformityTR CU 020/2011
TR CU 004/2011
UL approvalcULus Listed
Caution: This equipment is considered as open-type equipment. It must be mounted within an enclosure, that is suitably designed for protection against internal fire and personal injury resulting from accessibility to live parts according UL 508.
CCC approvalCertified by China Compulsory Certification (CCC)
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protectionIP67
Connectionterminal compartment
Material
HousingPlastic ABS, flame resistant
Optical facePlastic pane
Massapprox. 200 g
Dimensions
Height88 mm
Width25.8 mm
Depth65.5 mm
NoteSafety fuse ≤ 2 A (slow-blow) according to IEC 60127-2 Sheet 1
Recommendation: after a short circuit, check that the device is functioning correctly.

Classifications

SystemClasscode
ECLASS 13.027270902
ECLASS 12.027270902
ECLASS 11.027270902
ECLASS 10.0.127270902
ECLASS 9.027270902
ECLASS 8.027270902
ECLASS 5.127270902
ETIM 9.0EC002717
ETIM 8.0EC002717
ETIM 7.0EC002717
ETIM 6.0EC002717
ETIM 5.0EC002717
UNSPSC 12.139121528

Details: RLK29-55/25/116-Set

Function

Series 29 is a range of low-cost and, most importantly, reliable photoelectric sensors for monitoring industrial doors, elevators, and automatic gates. Their high degree of protection makes them the ideal solution for tasks outdoors and at thresholds, and in harsh environments. These "universal-voltage sensors" can be operated with any supply voltage from 24 V to 240 V, and with direct current or alternating current.

Informative Literature: RLK29-55/25/116-Set

Language Selection:
We are sorry, there are no documents for your language selection. Please select another language.

Product Documentation: RLK29-55/25/116-Set

Language Selection:
Brief InstructionsLanguageFile TypeFile Size
Instruction leaflet / BeipackzettelALLPDF408 KB

Design / Simulation: RLK29-55/25/116-Set

Language Selection:
CADLanguageFile TypeFile Size
CAD 3-D / CAD 3-DALLSTP213 KB
CAD Portal / CAD PortalALLLINK---

Approvals: RLK29-55/25/116-Set

Language Selection:
CertificatesCert No.LanguageFile TypeFile Size
Canada USA UL Ordinary LocationUL-CA-L87056-31-52803002-0 / UL-US-L87056-11-52803002-0ALLPDF545 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-4716AALLPDF304 KB

Associated Products: RLK29-55/25/116-Set

Kit component

Reflector, round ø 84 mm, central mounting holefa
Mounting bracket for rear wall mountingfa
Robust, compact photoelectric sensor for single-beam gate protection, Not sensitive to ambient light, even with energy saving lamps, Tamper-proof, no operating controls, Version for universal voltages, Relay output, Light source: LED, Light type: modulated visible red light , 640 nm, Operating voltage: 24 ... 230 V AC/DC, Switching type: light-on, Signal output: Relay, 1 alternatorfa
Accessories
Mounting bracket fa
Mounting bracket for rear wall mountingfa