Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
General specifications | ||
---|---|---|
Signal type | Digital Output | |
Supply | ||
Connection | Power Rail or terminals 11+, 12- | |
Rated voltage | 20 ... 30 V DC | |
Ripple | ≤ 10 % | |
Rated current | ≤ 52 mA | |
Power dissipation | typ. 1.2 W | |
Power consumption | < 1.5 W | |
Input | ||
Connection side | control side | |
Connection | terminals 7+, 8+, 9+ | |
Signal level | 1-signal: 15 ... 30 V DC ; input current: approx. 2.3 mA at 24 V DC 0-signal: 0 ... 5 V DC or open input |
|
Response delay | 5 ... 30 ms (typical 10 ms) | |
Output | ||
Connection side | field side | |
Internal resistor | max. 410 Ω | |
Current | typ. 18 mA | |
Voltage | typ. 16 V | |
Limit | current IE: ≥ 17 mA; typ. 18 mA voltage UE: ≥ 15.3 V; typ. 16 V |
|
Open loop voltage | min. 22.3 V | |
Connection | terminals 4+, 6- | |
Output current | 17 mA | |
Output signal | These values are valid for the rated operating voltages from 20 ... 30 V DC. | |
Transfer characteristics | ||
Switching frequency | 15 Hz | |
Galvanic isolation | ||
Input/power supply | not available | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Electromagnetic compatibility | NE 21:2012 | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | approx. 120 g | |
Dimensions | 20 x 107 x 115 mm (0.8 x 4.2 x 4.5 inch) (W x H x D) , housing type B1 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-type examination certificate | PTB 00 ATEX 2132 | |
Marking | II (1)GD [Ex ia] IIC [circuit(s) in zone 0/1/2] | |
Output | Ex ia | |
Voltage | 25.2 V DC | |
Current | 67.2 mA | |
Power | 423.5 mW (linear characteristic) | |
Supply | ||
Maximum safe voltage | 253 V AC/125 V DC without jumper 10-11, 60 V with jumper 10-11 (Attention! Um is no rated voltage.) | |
Input | ||
Maximum safe voltage | 60 V (Attention! Um is no rated voltage.) | |
Galvanic isolation | ||
Input/Output | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
Output/power supply | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | |
Directive conformity | ||
Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 | |
General information | ||
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
System | Classcode |
---|---|
ECLASS 13.0 | 27210101 |
ECLASS 12.0 | 27210190 |
ECLASS 11.0 | 27210190 |
ECLASS 10.0.1 | 27210190 |
ECLASS 9.0 | 27210190 |
ECLASS 8.0 | 27210190 |
ECLASS 5.1 | 27210121 |
ETIM 9.0 | EC001485 |
ETIM 8.0 | EC001485 |
ETIM 7.0 | EC001485 |
ETIM 6.0 | EC001485 |
ETIM 5.0 | EC001485 |
UNSPSC 12.1 | 39121008 |
This isolated barrier is used for intrinsic safety applications. It supplies power to solenoids and other similar loads.
It is controlled by two "OR" and one "AND" configured logic input.
At full load, 15.3 V at 17 mA is available for the hazardous area load. The output signal has a resistive characteristic.
An override/test jack feature is available on the front plate of the device.
By engaging the service plug, the logic inputs are bypassed and the output is energized. The operation of this test feature is indicated by a red LED.
Literature | Language | File Type | File Size |
---|---|---|---|
Application Report - Biological Cleaning of Wastwater and Secondary Sedimentation Stage | ENG | 566 KB | |
Application Report - Energy Generation in Wastwater Treatment Plants | ENG | 532 KB | |
Application Report - Generating Electricity in Coal-Fired Power Plants | ENG | 412 KB | |
Application Report - Sand Trap and Preliminary Sedimentation Stage | ENG | 448 KB | |
Application Report - Screening Systems in Sewage Treatment Plants | ENG | 577 KB | |
Application Report - Sicherer Brennstofftransport in Kohlekraftwerken | ENG | 391 KB | |
Application Report - Water Inlet in Wastewater Treatment Plants | ENG | 526 KB |
Product information | Language | File Type | File Size |
---|---|---|---|
Application Guideline Solenoid Drivers | ENG | 734 KB | |
Safety and Security Documentation | |||
Instruction manual | ENG | 49 KB | |
Manuals | |||
Manual | ENG | 3685 KB |
CAD | Language | File Type | File Size |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 105 KB |
CAD Portal / CAD Portal | ALL | LINK | --- |
CAE | |||
EPLAN macro EDZ / EPLAN Makro EDZ | ALL | EDZ | 56 KB |
Certificates | Cert No. | Language | File Type | File Size |
---|---|---|---|---|
Europe PTB ATEX Category (1) GD | PTB 00 ATEX 2132 | ALL | 554 KB | |
Pepperl+Fuchs Functional Safety Assessment | FS-0065PF-20A | ALL | 69 KB | |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-1949A | ALL | 52 KB |
Matching System Components | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
Accessories | ||||||
|
||||||
|
||||||
|