Serviceline Industrial Sensors
Serviceline Explosion Protection

Inductive sensor NBB10-30GK60-AR-1M

NBB10-30GK60-AR-1M
  • Relay output
  • Operating distance 10 mm
  • SPDT output
  • Switch load currents to 6 Amps

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  NBB10-30GK60-AR-1M

General specifications
Switching functionchange-over contact
Output typerelay
Rated operating distance10 mm
Installationflush
Output polarityDC
Reduction factor rAl 0.4
Reduction factor rCu 0.3
Reduction factor r304 0.85
Output typeRelay output
Mechanical lifeNo load: 2 x 107 operations Full load: 1 x 105 switching cycles
Nominal ratings
Operating voltage10 ... 30 V DC
Switching frequency20 Hz
Hysteresisapprox. 10 %
Reverse polarity protectionyes
Short-circuit protectionno
Operating current≤ 50 mA
Switching state indicatorLED, yellow
Output
Switching voltagemax 28 V DC
Switching currentmax 6 A DC resistive load
Switching powermax 180 W
Compliance with standards and directives
Standard conformity
StandardsEN IEC 60947-5-2
Approvals and certificates
UL approvalcULus Listed, General Purpose
Ambient conditions
Ambient temperature-40 ... 70 °C (-40 ... 158 °F)
Mechanical specifications
Connection type1-meter cable, PVC heavy jacket, 5-conductor, #18 AWG
Core cross section0.75 mm2
Housing materialPBT
Sensing facePBT
Degree of protectionIP68
Dimensions
Length60 mm
Diameter30 mm

Classifications

SystemClasscode
ECLASS 13.027274001
ECLASS 12.027274001
ECLASS 11.027270101
ECLASS 10.0.127270101
ECLASS 9.027270101
ECLASS 8.027270101
ECLASS 5.127270101
ETIM 9.0EC002714
ETIM 8.0EC002714
ETIM 7.0EC002714
ETIM 6.0EC002714
ETIM 5.0EC002714
UNSPSC 12.139121550

Details: NBB10-30GK60-AR-1M

Product Documentation: NBB10-30GK60-AR-1M

Language Selection:
Product informationLanguageFile TypeFile Size
Installation conditionsENGPDF1054 KB

Design / Simulation: NBB10-30GK60-AR-1M

Language Selection:
CADLanguageFile TypeFile Size
CAD 3-D / CAD 3-DALLSTP75 KB
CAD Portal / CAD PortalALLLINK---

Approvals: NBB10-30GK60-AR-1M

Language Selection:
CertificatesCert No.LanguageFile TypeFile Size
Canada USA UL Ordinary LocationUL-US-L87056-11-41301991-3 / UL-CA-L87056-31-41301991-3ALLPDF1806 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-3462AALLPDF1230 KB
UK Declaration of Conformity (P+F)TDOC-6173_ENGENGPDF1285 KB

Associated Products: NBB10-30GK60-AR-1M

Accessories

Mounting flange, 30 mmfa
Plastic mounting adapter, 30 mmfa
Universal mounting bracket for cylindrical sensors with a diameter of 5 ... 30 mmfa
Mounting aidfa

Our amplify article gives interesting insights about the development of the new, modern portfolio of inductive proximity sensors from Pepperl+Fuchs. Get the whole story here! 

 

 

Knowledge Base for Inductive Sensors

The knowledge base for inductive sensors contains extensive expertise and supports you in the highly precise and smooth operation of the sensors in your machinery and plants.

VariKont with Active Shielding Technology

The VariKont inductive sensors with Active Shielding Technology ensure high switching distances, no matter the installation situation and the surrounding material. Benefit from easier equipment design and reduced costs!

Inductive Safety Sensors SIL 2 PL d

As the SIL 2/PL d inductive safety sensors have no dead band, data transfer can occur with no minimum distance between sensor and target. Discover the optimized portfolio for demanding environments.