Serviceline Industrial Sensors
Serviceline Explosion Protection

FieldConnex® DTM Collection DTM FieldConnex

DTM FieldConnex
  • User interface for PROFIBUS components
  • Simple access to measurements, diagnostic and configuration data
  • Supports any FDT/DTM host

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  DTM FieldConnex

General specifications
DescriptionDevice type manager for FieldConnex® components:
HD2-GTR-4PA, PROFIBUS DP/PA gateway , *D0-TI-Ex8.PA.*, temperature multi-input device for PROFIBUS PA
, *D0-MIO-Ex12.PA*, multi-input/output for PROFIBUS PA , *D0-TI-Ex8.PA.*, temperature multi-input device for PROFIBUS PA
Software
Hardware requirementssee release notes
Software requirementsOptional: Unzip tool
Administrative privileges for the software installation
Operating systemsee release notes in the software package
LicensingFull license included

Classifications

SystemClasscode
ECLASS 13.027242505
ECLASS 12.027242502
ECLASS 11.027242502
ECLASS 10.0.127242502
ECLASS 9.027242502
ECLASS 8.027242502
ECLASS 5.127242502
ETIM 9.0EC000757
ETIM 8.0EC001416
ETIM 7.0EC001416
ETIM 6.0EC001416
ETIM 5.0EC000809
UNSPSC 12.143232901

Details: DTM FieldConnex

Function

The FieldConnex ® device type manager (DTM) collection provides the user interface and access to all process-relevant data online in real-time. The collection contains DTMs for FieldConnex process interfaces and PROFIBUS gateways. The DTM provides a standard interface for integration into any distributed control system supporting FDT/DTM technology.

A DTM enables configuration and diagnostics independently of the control, operating, plant asset management, or engineering system. It provides remote access, thus improving safety for personnel and reducing time and effort for repair and plant upkeep. Early warnings from an instrument via DTM enable proactive plant upkeep only when it is needed and in time for the plant to remain in production.

For DTMs regarding advanced diagnostic modules and gateways see separate datasheets.

Product Documentation: DTM FieldConnex

Language Selection:
Brief InstructionsLanguageFile TypeFile Size
Quick Installation Guide - DTM Collection FieldConnexENGPDF2822 KB
Software Information
Release Notes - DTM Collection FieldConnexENGPDF203 KB
End-user software license agreement (EULA)ENGPDF38 KB

Software: DTM FieldConnex

Language Selection:
Device Description Files/DriversRelease InfoFile TypeFile Size
DTM Collection FieldConnex / DTM Collection FieldConnex1.9.0.2268ZIP35363 KB

Associated Products: DTM FieldConnex

Accessory of

FieldConnex® Fieldbus, Gateway module for fieldbus power hub for PROFIBUS PA to PRFIBUS DP Master communication, PROFIBUS DP V1 / For 4 segments PA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Optional redundant configuration, Installation in Zone 2/Class I, Div. 2, Up to 12 Mbit/s, auto adapting, IECEx approval, International, Europe, USA, Canadapa
FieldConnex® Fieldbus, Multi-input/output for digital signals, module for DIN rail mounting, For discrete inputs and outputs, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PApa
FieldConnex® Fieldbus, Multi-input/output for digital signals, module for DIN rail mounting, For discrete inputs and outputs, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PApa
FieldConnex® Fieldbus, Multi-input/output for digital signals, module for DIN rail mounting, For discrete inputs and outputs, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA, IECEx approval, Dust protection, International, Europe, USA, Canadapa
FieldConnex® Fieldbus, Temperature multi-input, electronic component for control cabinet installation, For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA, IECEx approval, Dust protection, Europe, USA, Canadapa
FieldConnex® Fieldbus, For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA, IECEx approval, Dust protection, Europe, USA, Canada, Device coupler location: non-explosion hazardous area
Zone 2 - high-power trunk
Zone 1 - high-power trunk
Division 2 - high-power trunk
Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunkpa
FieldConnex® Fieldbus, Multi-input/output for digital signals, stand-alone device with aluminum housing for field installation, For discrete inputs and outputs, Aluminum cast iron, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For PROFIBUS PA, IECEx approval, Dust protection, International, Europe, USA, Canadapa
FieldConnex® Fieldbus, Gateway module for fieldbus power hub for PROFINET to PROFIBUS PA communication, Gateway PROFINET RT to 4 x PROFIBUS PA segments, Up to 32 devices per PROFIBUS PA segment, Installation in Zone 2/Class I, Div. 2, Ring and system redundancy, Integrated webserver for diagnostics, IECEx approval, International, Europe, USA, Canadapa
FieldConnex®, Ethernet-APL rail field switch with 16 intrinsically safe Ex ia spur ports and spring terminals, Managed Ethernet-APL field switch for process industries, PROFINET MRP, S2 redundancy and dynamic reconfiguration, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC ... 60 VDC, Installation in Zone 2, IECEx approval, International, Europe, Device coupler location: non-explosion hazardous area
Zone 2
, Device coupler location [2]: Zone 2pa
FieldConnex®, Ethernet-APL rail field switch with 8 intrinsically safe Ex ia spur ports and screw terminals with proxy support selectable for PROFIBUS PA field devices, Managed Ethernet-APL field switch for process industries, PROFINET MRP, S2 redundancy and dynamic reconfiguration, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC ... 60 VDC, Installation in Zone 2, IECEx approval, International, Europepa
FieldConnex®, Ethernet-APL rail field switch with 16 intrinsically safe Ex ia spur ports and screw terminals with proxy support selectable for PROFIBUS PA field devices, Managed Ethernet-APL field switch for process industries, PROFINET MRP, S2 redundancy and dynamic reconfiguration, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC ... 60 VDC, Installation in Zone 2, IECEx approval, International, Europepa
FieldConnex®, Ethernet-APL rail field switch with 24 intrinsically safe Ex ia spur ports and screw terminals with proxy support selectable for PROFIBUS PA field devices, Managed Ethernet-APL field switch for process industries, PROFINET MRP, S2 redundancy and dynamic reconfiguration, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC ... 60 VDC, Installation in Zone 2, IECEx approval, International, Europepa
FieldConnex®, Ethernet-APL rail field switch with 8 intrinsically safe Ex ia spur ports and screw terminals, Managed Ethernet-APL field switch for process industries, PROFINET MRP, S2 redundancy and dynamic reconfiguration, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC ... 60 VDC, Installation in Zone 2, IECEx approval, International, Europe, Device coupler location: non-explosion hazardous area
Zone 2
, Device coupler location [2]: Zone 2pa
FieldConnex®, Ethernet-APL rail field switch with 16 intrinsically safe Ex ia spur ports and screw terminals, Managed Ethernet-APL field switch for process industries, PROFINET MRP, S2 redundancy and dynamic reconfiguration, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC ... 60 VDC, Installation in Zone 2, IECEx approval, International, Europe, Device coupler location: non-explosion hazardous area
Zone 2
, Device coupler location [2]: Zone 2pa
FieldConnex®, Ethernet-APL rail field switch with 24 intrinsically safe Ex ia spur ports and screw terminals, Managed Ethernet-APL field switch for process industries, PROFINET MRP, S2 redundancy and dynamic reconfiguration, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC ... 60 VDC, Installation in Zone 2, IECEx approval, International, Europe, Device coupler location: non-explosion hazardous area
Zone 2
, Device coupler location [2]: Zone 2pa
FieldConnex®, Ethernet-APL rail field switch with 8 intrinsically safe Ex ia spur ports and spring terminals with proxy support selectable for PROFIBUS PA field devices, Managed Ethernet-APL field switch for process industries, PROFINET MRP, S2 redundancy and dynamic reconfiguration, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC ... 60 VDC, Installation in Zone 2, IECEx approval, International, Europepa
FieldConnex®, Ethernet-APL rail field switch with 16 intrinsically safe Ex ia spur ports and spring terminals with proxy support selectable for PROFIBUS PA field devices, Managed Ethernet-APL field switch for process industries, PROFINET MRP, S2 redundancy and dynamic reconfiguration, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC ... 60 VDC, Installation in Zone 2, IECEx approval, International, Europepa
FieldConnex®, Ethernet-APL rail field switch with 24 intrinsically safe Ex ia spur ports and spring terminals with proxy support selectable for PROFIBUS PA field devices, Managed Ethernet-APL field switch for process industries, PROFINET MRP, S2 redundancy and dynamic reconfiguration, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC ... 60 VDC, Installation in Zone 2, IECEx approval, International, Europepa
FieldConnex®, Ethernet-APL rail field switch with 8 intrinsically safe Ex ia spur ports and spring terminals, Managed Ethernet-APL field switch for process industries, PROFINET MRP, S2 redundancy and dynamic reconfiguration, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC ... 60 VDC, Installation in Zone 2, IECEx approval, International, Europe, Device coupler location: non-explosion hazardous area
Zone 2
, Device coupler location [2]: Zone 2pa
FieldConnex®, Ethernet-APL rail field switch with 24 intrinsically safe Ex ia spur ports and spring terminals, Managed Ethernet-APL field switch for process industries, PROFINET MRP, S2 redundancy and dynamic reconfiguration, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC ... 60 VDC, Installation in Zone 2, IECEx approval, International, Europe, Device coupler location: non-explosion hazardous area
Zone 2
, Device coupler location [2]: Zone 2pa
FieldConnex®, Ethernet-APL rail field switch with 24 intrinsically safe Ex ic spur ports and spring terminals with proxy support selectable for PROFIBUS PA field devices, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP, S2 redundancy and dynamic reconfiguration, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC ... 60 VDC, IECEx approval, Internationalpa
FieldConnex®, Ethernet-APL rail field switch with 8 intrinsically safe Ex ic spur ports and screw terminals with proxy support selectable for PROFIBUS PA field devices, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP, S2 redundancy and dynamic reconfiguration, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC ... 60 VDC, IECEx approval, Internationalpa
FieldConnex®, Ethernet-APL rail field switch with 24 intrinsically safe Ex ic spur ports and screw terminals, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP, S2 redundancy and dynamic reconfiguration, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC ... 60 VDC, IECEx approval, International, Europepa
FieldConnex®, Ethernet-APL rail field switch with 24 intrinsically safe Ex ic spur ports and spring terminals, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP, S2 redundancy and dynamic reconfiguration, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC ... 60 VDC, IECEx approval, International, Europepa
FieldConnex®, Ethernet-APL rail field switch with 16 intrinsically safe Ex ic spur ports and screw terminals, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP, S2 redundancy and dynamic reconfiguration, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC ... 60 VDC, IECEx approval, International, Europepa
FieldConnex®, Ethernet-APL rail field switch with 24 intrinsically safe Ex ic spur ports and screw terminals with proxy support selectable for PROFIBUS PA field devices, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP, S2 redundancy and dynamic reconfiguration, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC ... 60 VDC, IECEx approval, Internationalpa
FieldConnex®, Ethernet-APL rail field switch with 8 intrinsically safe Ex ic spur ports and screw terminals, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP, S2 redundancy and dynamic reconfiguration, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC ... 60 VDC, IECEx approval, International, Europepa
FieldConnex®, Ethernet-APL rail field switch with 8 intrinsically safe Ex ic spur ports and spring terminals, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP, S2 redundancy and dynamic reconfiguration, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC ... 60 VDC, IECEx approval, International, Europepa
FieldConnex®, Ethernet-APL rail field switch with 16 intrinsically safe Ex ic spur ports and spring terminals with proxy support selectable for PROFIBUS PA field devices, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP, S2 redundancy and dynamic reconfiguration, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC ... 60 VDC, IECEx approval, Internationalpa
FieldConnex®, Ethernet-APL rail field switch with 16 intrinsically safe Ex ic spur ports and screw terminals with proxy support selectable for PROFIBUS PA field devices, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP, S2 redundancy and dynamic reconfiguration, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC ... 60 VDC, IECEx approval, Internationalpa
FieldConnex®, Ethernet-APL rail field switch with 8 intrinsically safe Ex ic spur ports and spring terminals with proxy support selectable for PROFIBUS PA field devices, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP, S2 redundancy and dynamic reconfiguration, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC ... 60 VDC, IECEx approval, Internationalpa
FieldConnex®, Ethernet-APL rail field switch with 16 intrinsically safe Ex ic spur ports and spring terminals, Managed Ethernet-APL field switch for process industries, Powered spur ports intrinsically safe Ex ic according to 2-WISE and FISCO, PROFINET MRP, S2 redundancy and dynamic reconfiguration, 2 ports each for 1000BASE-T and SFP transceivers, Redundant power input 20 VDC ... 60 VDC, IECEx approval, International, Europepa
Accessories
Universal DTM host platform, For all DTMs of Pepperl+Fuchs, Approved FDT/DTM technology, Free of charge, Internet download possiblepa
Universal DTM host platform, For all DTMs of Pepperl+Fuchs, Approved FDT/DTM technology, Free of charge, Download from Pepperl+Fuchs websitepa