General specifications |
Sensing range | 20 ... 250 mm |
Adjustment range | 25 ... 250 mm |
Dead band | 0 ... 20 mm |
Standard target plate | 10 mm x 10 mm |
Transducer frequency | approx. 400 kHz |
Response delay | minimum : 8 ms factory setting: 29 ms |
Sensor cycle time | ≥ 8 ms (factory setting) ; programmable to 60 s |
Memory |
Non-volatile memory | EEPROM |
Write cycles | 300000 |
Indicators/operating means |
LED green | solid: power on flashing: standby mode or IO-Link communication |
LED yellow | solid: object in evaluation range flashing: programming of the limits, object detected |
LED red | solid: fault flashing: programming limits, object not detected |
Electrical specifications |
Operating voltage | 18 ... 30 V DC , ripple 10 %SS
|
No-load supply current | ≤ 50 mA |
Power consumption | ≤ 500 mW |
Time delay before availability | ≤ 300 ms |
Interface |
Interface type | IO-Link (available after activation via programming button until next reset) |
Input/Output |
Input/output type | 1 synchronization connection, bidirectional |
| 0 Level | 0 ... 1 V |
| 1 Level | 2.5 V ... UB |
| Input impedance | > 22 kΩ |
| Output current | current source < 2.5 mA |
| Pulse length | ≥ 1 ms with external control, low active |
Synchronization frequency | |
| Common mode operation | ≤ 141 Hz |
| Multiplex operation | ≤ 141 Hz / n , n = number of sensors , n ≤ 10
|
Output |
Output type | 1 analog output 0 (4) ... 20 mA or 1 analog output 0 ... 10 V |
Resolution | current output: evaluation range [mm]/3200 but ≥ 0.35 mm voltage output: evaluation range [mm]/4000 but ≥ 0.35 mm
|
Deviation of the characteristic curve | ≤ ± 1 % of full-scale value |
Repeat accuracy | ≤ ± 0.1 % of full-scale value |
Load impedance | current output: ≤ 500 Ohm voltage output: ≥ 1000 Ohm |
Temperature influence | ≤ ± 0.75 % of the end value (with temperature compensation)
from 10 minutes after switching on the sensor ; 0.17 %/K (without temperature compensation) |
Compliance with standards and directives |
Standard conformity | |
| Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003 IEC 61131-9:2013 |
Approvals and certificates |
UL approval | cULus Listed, Class 2 Power Source |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature | current output -25 ... 60 °C (-13 ... 140 °F) voltage output -25 ... 70 °C (-13 ... 158 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications |
Connection type | cable PUR , 2 m |
Core cross section | 4 x 0.19 mm2 |
Degree of protection | IP67 |
Material | |
| Housing | Polycarbonate |
| Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam |
Installation position | any position |
Mass | 51 g |
Tightening torque, fastening screws | max. 0.2 Nm |
Dimensions | |
| Height | 31 mm |
| Width | 12 mm |
| Length | 23 mm |
Factory settings |
Output | near limit: 25 mm far limit: 250 mm Output mode: rising ramp output type: 4 ... 20 mA |
Beam width | wide |