Terminal resistor V15S-TR-CAN/DN-120R

V15S-TR-CAN/DN-120R
  • Suitable for DeviceNet and CANopen
  • Specific design protects against loosening and inaccurate installation
  • Pins 4 and 5 bridged

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  V15S-TR-CAN/DN-120R

Product Description
Terminal resistor M12 male straight A-coded 5-pin, for DeviceNet, CANopen
General specifications
Connector 1
Connectionplug
Construction typeM12
Stylestraight
Lockingscrew connection
Number of pins5
CodingA-coded
Customizationpin 4 and 5 bridged , resistance 120 Ohm
Electrical specifications
Operating voltagemax. 24 V DC
Operating currentmax. 4 A per contact
Conformity
Degree of protectionEN 60529
Fieldbus standardCANopen , DeviceNet
Plug connectionconnector M12 x 1 : IEC 61076-2-101
Ambient conditions
Ambient temperature-40 ... 90 °C (-40 ... 194 °F)
Pollution degree3
Mechanical specifications
Plug connector
Tightening torque0.6 Nm
Loosening protectionavailable
Tool installationstraight knurling and hexagon nut SW = 14 mm
Mating cyclesmin. 100
Degree of protectionIP68 / IP69
Mass8 g
Material
Plug connector
Screw connectionZinc diecast, nickel-plated
BodyTPU, black
Contact surfacegold plated (Au)
FlammabilityV-2

Classifications

SystemClasscode
ECLASS 13.027260190
ECLASS 12.019070403
ECLASS 11.019070403
ECLASS 10.0.119070403
ECLASS 9.027279090
ECLASS 8.027279290
ECLASS 5.127279201
ETIM 9.0EC003015
ETIM 8.0EC003015
ETIM 7.0EC003015
ETIM 6.0EC003015
ETIM 5.0EC002585
UNSPSC 12.131251501

Details: V15S-TR-CAN/DN-120R

Associated Products: V15S-TR-CAN/DN-120R

Accessory of

Inertial measurement unit for inclination, acceleration and rotation rate measurement in 3-axis each, Dynamic inclination measurement despite external acceleration, Adjustable ranges for compensation of external accelerations, disturbances, Adjustable thresholds for detection of measured value overruns, Measurement of inclination, acceleration and rotation rate in 3 axis each, CAN bus with SAE J1939 protocolfa

E1-Type approval, Measuring range 0 ... 360°, High shock resistance, Extended temperature range
-40 ... +85 °C, CANopen interface, Increased noise immunity 100 V/mfa

E1-Type approval, Measuring range 0 ... 360°, High shock resistance, Extended temperature range
-40 ... +85 °C, CANopen interface, Increased noise immunity 100 V/mfa

Radar sensor for distance and velocity measuring up to 25 m sensing range, with M12 connector, CANopen interface, Sensing range up to 25 m, Degree of protection IP68 / IP69fa
Inertial measurement unit for inclination, acceleration and rotation rate measurement in 3-axis each, Dynamic inclination measurement despite external acceleration, Adjustable ranges for compensation of external accelerations, disturbances, Adjustable thresholds for detection of measured value overruns, Measurement of inclination, acceleration and rotation rate in 3 axis each, CAN bus with CANopenfa
E1-Type approval, High shock resistance, Extended temperature range
-40 ... +85 °C, Measuring range -15° ... +15°, CAN bus with SAE J1939 protocolfa
E1-Type approval, High shock resistance, Extended temperature range
-40 ... +85 °C, Measuring range -60° ... +60°, CAN bus with SAE J1939 protocolfa
E1-Type approval, High shock resistance, Extended temperature range
-40 ... +85 °C, CAN bus with SAE J1939 protocol, Measuring range -85° ... +85°fa
E1-Type approval, Measuring range 0 ... 360°, High shock resistance, Extended temperature range
-40 ... +85 °C, CAN bus with SAE J1939 protocolfa
E1-Type approval, High shock resistance, Extended temperature range
-40 ... +85 °C, CANopen interface, Measuring range -15° ... +15°, Increased noise immunity 100 V/mfa
E1-Type approval, Measuring range 0 ... 360°, High shock resistance, Extended temperature range
-40 ... +85 °C, CAN bus with SAE J1939 protocolfa
Single head system, CANopen interface, E1-Type approval, High EMC resistance, Series: -L2M, Interface type: CAN, Communication protocol: CANopen, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, UN/ECE Regulation No. 10 (E1): Type-approval number: 10R-069608, Connection type: Connector plug, Housing: PA-GF35, Threading: M12fa
Single head system, CANopen interface, E1-Type approval, High EMC resistance, Series: -L2M, Interface type: CAN, Communication protocol: CANopen, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, UN/ECE Regulation No. 10 (E1): Type-approval number: 10R-069608, Connection type: Connector plug, Housing: PA-GF35, Threading: M12fa
Single head system, CANopen interface, E1-Type approval, High EMC resistance, Series: -L2M, Interface type: CAN, Communication protocol: CANopen, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, UN/ECE Regulation No. 10 (E1): Type-approval number: 10R-069608, Connection type: Connector plug, Housing: PA-GF35, Threading: M12fa
Single head system, CANopen interface, E1-Type approval, High EMC resistance, Series: -L2M, Interface type: CAN, Communication protocol: CANopen, UL approval: UL Recognized , General purpose , Class 2 power source, CCC approval: CCC approval / marking not required for products rated ≤36 V, UN/ECE Regulation No. 10 (E1): Type-approval number: 10R-069608, Connection type: fixed cable with plug, Housing: PA-GF35, Connection assembly: AMP connector Superseal 282107-1
AMP contact Superseal 282109-1fa
Single head system, CANopen interface, E1-Type approval, High EMC resistance, Series: -L2M, Interface type: CAN, Communication protocol: CANopen, UL approval: UL Recognized , General purpose , Class 2 power source, CCC approval: CCC approval / marking not required for products rated ≤36 V, UN/ECE Regulation No. 10 (E1): Type-approval number: 10R-069608, Connection type: fixed cable with plug, Housing: PA-GF35fa
Single head system, CANopen interface, E1-Type approval, High EMC resistance, Series: -L2M, Interface type: CAN, Communication protocol: CANopen, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, UN/ECE Regulation No. 10 (E1): Type-approval number: 10R-069608, Connection type: Connector plug, Housing: PA-GF35, Threading: M12fa
Multi-ray LED scanner for measuring the distance to an object, measuring method: PRT, measuring range: up to 8 m on white, 2x M12 plugs, Distance measurement using object, Two-dimensional measurement with no moving parts, Measurement using eye-safe LED technology, 88° scanning angle, CANopen interfacefa
Radar sensor for distance and velocity measuring up to 25 m sensing range, with AMP connector, CANopen interface, Sensing range up to 25 m, Degree of protection IP68 / IP69fa
Radar sensor for distance and velocity measuring up to 25 m sensing range, with 2m cable, CANopen interface, Sensing range up to 25 m, Degree of protection IP68 / IP69fa
Radar sensor for distance and velocity measuring up to 25 m sensing range, with DEUTSCH connector, CANopen interface, Sensing range up to 25 m, Degree of protection IP68 / IP69fa
Accessories
torque screwdriver (0.6 Nm)fa
plug-in cap M12fa
Unlocking protector for M12 connectorfa
Marking ring for M12 plugfa
Marking ring for M12 plugfa
Marking ring for M12 plugfa
Marking ring for M12 plugfa
Marking ring for M12 plugfa
Marking ring for M12 plugfa
Visit the RFID Hub

Visit our "RFID Hub"—this special website is a knowledge base for RFID. Get answers on frequently asked questions and learn about typical RFID applications …