Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
Product Description |
---|
Optical high temperature identification system, 140 to 200 mm |
General specifications | ||
---|---|---|
Light source | Integrated LED lightning | |
Light type | infrared | |
Symbologies | Hole matrix Data format: decimal Data capacity: 6 (numerical) Orientation: omnidirectional |
|
Read distance | 140 ... 200 mm (factory setting) max. 260 mm | |
Reading field | 210 mm x 135 mm at max. read distance | |
Evaluation frequency | 5 Hz | |
Target velocity | triggered max. 0.5 m/s | |
Functional safety related parameters | ||
MTTFd | 51 a | |
Mission Time (TM) | 10 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Operation indicator | LED green: supply LED green: ready |
|
Function indicator | Yellow LED: trigger Yellow LED: code read Red LED: pre-fault Red LED: group error |
|
Electrical specifications | ||
Operating voltage | 24 V DC ± 15% , PELV | |
Operating current | 250 mA without output drivers | |
Interface | ||
Physical | Ethernet | |
Protocol | TCP/IP | |
Transfer rate | 100 MBit/s | |
Input | ||
Input voltage | to be applied externally 24 V ± 15% PELV | |
Number/Type | 1 trigger input 2 control unit inputs , optically decoupled | |
Input current | approx. 1 mA at 24 V DC | |
Output | ||
Number/Type | 1 electronic output, PNP, optically decoupled | |
Switching voltage | to be applied externally 24 V ± 15 % PELV | |
Switching current | 100 mA each output | |
Conformity | ||
Shock resistance | EN 60068-2-27:2009 | |
Vibration resistance | EN 60068-2-6:2008 | |
Emitted interference | EN 61000-6-4:2007+A1:2011 | |
Noise immunity | EN 61326-1:2013 | |
Photobiological safety | EN 62471:2008 exempt group | |
Approvals and certificates | ||
CE conformity | CE | |
Ambient conditions | ||
Ambient temperature | 0 ... 45 °C (32 ... 113 °F) | |
Storage temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP64 | |
Connection | 8-pin Harting HAN RJ-45 5-pin M12 socket Supplied ferrite sleeve for suppression of the Ethernet cable |
|
Material | ||
Housing | Metal /high-grade steel powder coated | |
Mass | approx. 3100 g | |
Dimensions | ||
Height | 116 mm | |
Width | 188 mm | |
Depth | 297 mm |
System | Classcode |
---|---|
ECLASS 13.0 | 27280103 |
ECLASS 12.0 | 27280103 |
ECLASS 11.0 | 27280103 |
ECLASS 10.0.1 | 27280103 |
ECLASS 9.0 | 27280103 |
ECLASS 8.0 | 27280103 |
ECLASS 5.1 | 27280103 |
ETIM 9.0 | EC002999 |
ETIM 8.0 | EC002999 |
ETIM 7.0 | EC002999 |
ETIM 6.0 | EC002999 |
ETIM 5.0 | EC002999 |
UNSPSC 12.1 | 43211701 |
The stationary scanner OIT200-F113-B12-CB is an optical identification system using the methods of industrial image processing, which finds application in automated manufacturing processes. In particular with bodyshell work, there are harsh ambient conditions, which complicate or render impossible the application of code carriers with electronic components due to cyclical changes in temperature, for example.
For this reason, the high-temperature identification system OIT is fitted with code carriers with massive metal plates provided with a perforated matrix, which can withstand temperatures up to 500 °C and high mechanical loads.
Simple installation as well as commissioning without complicated and long-winded TEACH-IN enable fast application. Plug-in connections for fast exchange of devices and the control with simple command sets through an Ethernet interface ensure very easy operation. A scratch resistant quartz glass pane, which can be replaced, if and when required, as well as the stable metal housing turn the OIT200-F113-B12-CB into a robust and powerful identification system.
Literature | Language | File Type | File Size |
---|---|---|---|
Application Report - Reliable Optical Identication in High-Temperature Environments | ENG | 218 KB |
Product information | Language | File Type | File Size |
---|---|---|---|
EtherNet/IP: OIT500 used with RTS-UP... | ENG | 640 KB | |
Reading window and permissible displacement of read-only tags | ENG | 111 KB | |
SIMATIC S7 Demo FB for EASY Mode Operation | ENG | 169 KB | |
Brief Instructions | |||
Instruction leaflet / Beipackzettel | ALL | 519 KB | |
Manuals | |||
Manual OIT****-F113-B12-CB* | ENG | 5550 KB |
CAD | Language | File Type | File Size |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 6938 KB |
CAD Portal / CAD Portal | ALL | LINK | --- |
Declaration of Conformity | Cert No. | Language | File Type | File Size |
---|---|---|---|---|
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-2494D | ALL | 34 KB | |
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F) | DOC-6625 | ALL | 30 KB |
Software Tools | Release Info | File Type | File Size |
---|---|---|---|
Software OITControl for configuration and start of operation / Software OITControl zur Konfiguration und Inbetriebnahme | V2.5.0 | ZIP | 12282 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|