Download the complete datasheet as a PDF:
General specifications | ||
---|---|---|
Type | sensor for conductive limit value detection | |
Equipment architecture | A measuring system consists of a suspension electrode HR-690121 with electrode relay KFA6-ER 1.6, KFD2-ER 1.6, KFD2-ER-Ex1.W.LB or KFA6-ER-Ex1.W.LB. |
|
Series | HR-690121 | |
Versions | HR-690121/05, suspension electrode, 5 m (5.5 yd) cable, PVC HR-690121/10, suspension electrode, 10 m (11 yd) cable, PVC HR-690121/20, suspension electrode, 20 m (22 yd) cable, PVC |
|
Input | ||
Measured variable | measuring voltage directly from the electrode relay | |
Output | ||
Output signal | electrode relay creates switch signal corresponding to the selected responsiveness. | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2006 , EN 61326-2-3:2006 | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Operating conditions | ||
Process conditions | ||
Process temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Material | thread, cable insulation and electrode: PVC electrode tip: stainless steel 1.4571/316Ti | |
Dimensions | electrode: Ø20 mm (0.8 inch), length 160 mm (6.3 inch) cable: length max. 20 m (21.9 yard) |
|
General information | ||
Supplementary information | Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
System | Classcode |
---|---|
ECLASS 13.0 | 27200507 |
ECLASS 12.0 | 27200507 |
ECLASS 11.0 | 27200507 |
ECLASS 10.0.1 | 27200507 |
ECLASS 9.0 | 27200507 |
ECLASS 8.0 | 27200507 |
ECLASS 5.1 | 27200507 |
ETIM 9.0 | EC001447 |
ETIM 8.0 | EC001447 |
ETIM 7.0 | EC001447 |
ETIM 6.0 | EC001447 |
ETIM 5.0 | EC001447 |
UNSPSC 12.1 | 41111950 |
An electrode relay provides the measuring AC voltage for the electrode.
If the product comes into contact with conductive batch, the measuring circuit between electrode and wall of vessel is closed and the electrode relay is switched.