Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Hent hele databladet som PDF:
Uddrag af datablad: Tekniske data for
F2D0-TI-Ex8.PA.*
Produkt beskrivelse |
Temperature multi-input, stand-alone device with aluminum housing for field installation |
General specifications |
Design / Mounting | Outside installation |
Installation in hazardous area | Zone 1 / Div. 1 |
Electronic component | Temperature Multi-Input Device RD0-TI-Ex8.PA* For technical data on installed electronic component see datasheet. |
Fieldbus connection |
Fieldbus type | PROFIBUS PA |
Input |
Number | 8 |
Directive conformity |
Electromagnetic compatibility | |
| Directive 2014/30/EU | EN 61326-1:2013 |
Standard conformity |
Galvanic isolation | EN 60079-11 |
Electromagnetic compatibility | NE 21:2011 |
Degree of protection | IEC 60529 |
Fieldbus standard | IEC 61158-2 |
Shock resistance | EN 60068-2-27 |
Vibration resistance | EN 60068-2-6 |
Ambient conditions |
Ambient temperature | see table 1 |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Relative humidity | ≤ 95 % non-condensing |
Shock resistance | 15 g , 11 ms |
Vibration resistance | 10 g , 10 ... 150 Hz |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 |
Mechanical specifications |
Connection type | plug-in terminals , spring terminal and screw terminal |
Core cross section | |
| Bus | up to 2.5 mm2 |
| Inputs | up to 2.5 mm2 |
Cable diameter | see table 2 |
Cable gland | sensor inputs M16, fieldbus M20 |
Housing material | Aluminum |
Degree of protection | IP67 |
Mass | 1800 g |
Mounting | wall mounting |
Data for application in connection with hazardous areas |
EU-type examination certificate | PTB 03 ATEX 2237 |
| Marking | II 2 (1) G Ex ia [ia Ga] IIC T4 Gb , II (1) G [Ex ia Ga] IIC , II (1) D [Ex ia Da] IIIC , II 3 G Ex ic IIC T4 Gc |
Bus | FISCO see EC-Type Examination Certificate |
| Voltage Ui | 24 V |
Inputs | see EC-Type Examination Certificate |
Certificate | PTB 03 ATEX 2238 X |
| Marking | II 3 G Ex nA IIC T4 Gc |
Galvanic isolation | |
| Bus | see Statement of Conformity |
| Input | see EC-Type Examination Certificate |
Directive conformity | |
| Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 |
International approvals |
FM approval | CoC 3025732 |
CSA approval | CoC 3025732C |
IECEx approval | |
| IECEx certificate | IECEx PTB 05.0001 IECEx PTB 05.0002X |
| IECEx marking | Ex ia [ia Ga] IIC T4 Gb [Ex ia Ga] IIC [Ex ia Da] IIIC Ex ic IIC T4 Gc Ex nA IIC T4 Gc |
General information |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Classifications
System | Classcode |
ECLASS 13.0 | 27242610 |
ECLASS 12.0 | 27242610 |
ECLASS 11.0 | 27242610 |
ECLASS 10.0.1 | 27242610 |
ECLASS 9.0 | 27242610 |
ECLASS 8.0 | 27242610 |
ECLASS 5.1 | 27242610 |
ETIM 9.0 | EC001601 |
ETIM 8.0 | EC001601 |
ETIM 7.0 | EC001601 |
ETIM 6.0 | EC001601 |
ETIM 5.0 | EC001604 |
UNSPSC 12.1 | 39121008 |
Details:
F2D0-TI-Ex8.PA.*
Product Documentation:
F2D0-TI-Ex8.PA.*
Design / Simulation:
F2D0-TI-Ex8.PA.*
Approvals:
F2D0-TI-Ex8.PA.*
Software:
F2D0-TI-Ex8.PA.*
Tilhørende produkter:
F2D0-TI-Ex8.PA.*
Matching System Components |
|
|
|
FieldConnex® Fieldbus, Temperature multi-input, electronic component for control cabinet installation, For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA, IECEx approval, Dust protection, Europe, USA, Canadapa |
|
Accessories |
|
|
|
User interface for PROFIBUS components, Simple access to measurements, diagnostic and configuration data, Supports any FDT/DTM hostpa |
|
|
|
|
Software for connecting people, information, systems, and devices, For applications developed using .NET, Required to run PACTwarepa |
|
|
|
|
Universal DTM host platform, For all DTMs of Pepperl+Fuchs, Approved FDT/DTM technology, Free of charge, Download from Pepperl+Fuchs websitepa |
|
|
|
|
Universal DTM host platform, For all DTMs of Pepperl+Fuchs, Approved FDT/DTM technology, Free of charge, Internet download possiblepa |
|
RSS Info Service for PANOS Updates
Stay informed when a new software update of PANOS, the operating system for Ethernet-APL switches, is released: With our RSS Feed you will get an email notfication in your inbox immediately after an update has been released.