Support Industrielle sensorer
Support Explosion Protection

Wireless sensor node WS-VAL-2N4-F406-B41-01-02

WILSEN.valve
WS-VAL-2N4-F406-B41-01-02
  • Battery operated
  • Data transfer via LoRaWAN
  • LoRaWAN downlink channel for querying and adjusting parameter values
  • Bluetooth interface for commissioning, parameterization and diagnostics

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Hent hele databladet som PDF:


Uddrag af datablad: Tekniske data for   WS-VAL-2N4-F406-B41-01-02

Produkt beskrivelse
Wireless sensor node with LoRaWAN interface, especially for monitoring the valve positions of 90° hand lever valves, for connecting up to 2 NAMUR dual sensors
Main sensor
Suitable sensorsinductive dual sensors , output type: NAMUR
Number of connectable sensorsup to 2
Query interval- cylically according to the set LoRaWan transmission interval and or GPS acquistion interval
- if required, additionally triggered by events at intervals of 1 min ... 24 h
Integrated sensor technology
GPS sensorfor geo-positioning
Acquisition interval30 min ... 24 h
Temperature sensor
Resolution0.5 °C
Accuracy± 2 °C
Electrical specifications
Battery typehigh capacity lithium battery 3.6 V , 13000 mAh
Operating durationbattery lifetime approx. 10 years under Central European environmental conditions, 3 measurements and 3 wireless transmission per day with sufficient network coverage.
Interface 1
Interface typeBluetooth 5.0 LE
Transmitter radiated power+ 8 dBm
Frequency range2402 ... 2480 MHz
Interface 2
Interface typeLoRaWAN
SpecificationLoRaWAN interface specification V1.0.3
Device typeLoRaWAN class A device
Transmitter frequency868 MHz
Transmitter radiated power+ 14 dBm
Frequency range863 ... 870 MHz (Europe)
Transmission interval10 min ... 24 h
Inputs
Number of channels2
Connectionmax. cable length 10 m
Input typeNAMUR
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 301 489-1 V2.2.3:2019
EN 301 489-3 V2.1.1:2019
EN 301 489-17 V3.2.4:2020
EN 301 489-19 V2.1.1:2019
Radio and telecommunication terminal equipment
Directive 2014/53/EUEN 300 220-2 V3.1.1:2017
EN 300 328 V2.2.2:2019
EN 303 413 V1.1.1:2017
RoHS
Directive 2011/65/EU (RoHS)EN 63000:2018
Conformity
Mech. capacityEN IEC 60947-5-2:2020
IEC 60947-5-2:2019
Shock resistanceEN IEC 60947-5-2:2020
IEC 60947-5-2:2019
Vibration resistanceEN IEC 60947-5-2:2020
IEC 60947-5-2:2019
Climatic conditionsEN IEC 60947-5-2:2020
IEC 60947-5-2:2019
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection typesocket
Degree of protectionIP66 / IP67
Material
HousingPC (UL94-V0)
Socketbrass, nickel-plated
Socket
ThreadingM12 x 1
Number of pins4
Mass570 g
Dimensions
Height74 mm
Width81 mm
Length182 mm
Factory settings
Default settingLoRaWAN transmission interval = 24 h
LoRaWAN Downlink channel = enabled
LoRaWAN Downlink acknowledgement = enabled
GPS = disabled

Classifications

SystemClasscode
ECLASS 13.027272803
ECLASS 12.027272803
ECLASS 11.027272803
ECLASS 10.0.127272803
ECLASS 9.027272803
ECLASS 8.027272803
ECLASS 5.127272803
ETIM 9.0EC001849
ETIM 8.0EC001849
ETIM 7.0EC001849
ETIM 6.0EC001849
ETIM 5.0EC001849
UNSPSC 12.141111960

Details: WS-VAL-2N4-F406-B41-01-02

Informative Literature: WS-VAL-2N4-F406-B41-01-02

Language Selection:
LiteratureSprogFil typeFil størrelse
Application Report - Smart Position Feedback from Hand Lever ValvesENGPDF322 KB

Product Documentation: WS-VAL-2N4-F406-B41-01-02

Language Selection:
Product informationSprogFil typeFil størrelse
Brief Instructions - Battery Lifetime Calculator for WILSEN DevicesENGPDF148 KB
Downlink Description WS-VAL-*-F406-B41-*-02-*ENGPDF487 KB
Integration into a LoRa Network for WS-UCC*-F406-B15-B41-01-02ENGPDF1833 KB
Payload Description (Uplink) for WS-VAL-*-F406-B41-*-02-*ENGPDF208 KB
Brief Instructions
Instruction leaflet / BeipackzettelALLPDF546 KB

Design / Simulation: WS-VAL-2N4-F406-B41-01-02

Language Selection:
CADSprogFil typeFil størrelse
CAD 3-D / CAD 3-DALLSTP10341 KB

Approvals: WS-VAL-2N4-F406-B41-01-02

Language Selection:
Declaration of ConformityCertifikat nr.SprogFil typeFil størrelse
EU Declaration of Conformity (P+F) / EU-Konformitätserklärung (P+F)DOC-7394AALLPDF38 KB

Tilhørende produkter: WS-VAL-2N4-F406-B41-01-02

Accessories

Extended temperature range, Valve position detection, Suitable for 2:1 technology, Switching function: 2 x normally closed (NC), Output type: NAMUR, Installation: flush mountable, Output type: 2-wire, Construction type: Dual sensor, Series: Dual sensor, Suitable for 2:1 technology, Safety Integrity Level (SIL): SIL 2, Type of voltage: DC, Equipment protection level Ga: IECEx TUN 17.0021X, Equipment protection level Gb: IECEx TUN 17.0021X, Equipment protection level Da: IECEx TUN 17.0021Xfa
Cordset M12 socket straight to M12 plug straight A-coded, 4-pin, PUR cable black, UL-approved, drag chain suitable, torsion resistantfa
fa
fa
Material: stainless steel 1.4301 / AISI 304fa
WILSEN.sonic

Get to know WILSEN.sonic.level and WILSEN.sonic.distance—our specialists for reliable detection and transmission of fill levels and distances in challenging environments.

WILSEN.valve and WILSEN.node

Familiarize yourself with WILSEN.valve and WILSEN.node—our specialists for wireless monitoring of manual valves and highly flexible object presence detection.