Key Benefits at a Glance
- 1-channel isolated barrier
- 24 V DC supply (bus powered)
- Voltage input 0 mV ... ± 50 mV
- Voltage output 0 mV ... ± 50 mV
- Selectable up/downscale sensor breakage detection
- Fault output signal
Show more


Note
All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
EN
- DE
- EN
- ES
- FR
- PL
Technical data of HiC2065
Signal type | Analog input |
Connection | SL1: 1a, 1b(-); 2a, 2b(+) | |
Rated voltage | Ur | 20 ... 30 V DC bus powered via Termination Board |
Ripple | within the supply tolerance | |
Rated current | Ir | ≤ 22 mA |
Power dissipation/power consumption | 0.7 W max. | |
Lockout voltage | > 11 V DC |
Connection side | field side | |
Connection | SL2: 5a(+), 5b(-) | |
Input resistance | ≥ 16 MΩ | |
Transmission range | 0 ... ± 50 mV | |
Offset voltage/current | ≤ 5 µV / ≤ 5 nA |
Connection side | control side | |
Connection | SL1: 8a(+), 7a(-) | |
Voltage | 0 ... ± 50 mV | |
Load | Accuracy figures for infinite load impedance. Additional 0.03 % of span for a load resistance of 10 kΩ | |
Output resistance | max. 3 Ω | |
Line fault detection | input: ± 100 mV output: +200 mV, -115 mV |
Connection | SL1: 6b | |
Output type | open collector transistor (internal fault bus) | |
Fault voltage | < Vcc/2 (when connected to Vcc via 10 kΩ pull up resistor) |
Deviation | ||||||||
| ||||||||
Absolute | < 0.25 K at 30 V voltage supply | |||||||
Bandwidth | DC to > 350 Hz (-3 dB) | |||||||
Settling time | < 2 ms | |||||||
Rise time/fall time | ≤ 1 ms |
Output/power supply | functional insulation, rated insulation voltage 50 V AC |
Display elements | LEDs | |
Control elements | DIP switch | |
Configuration | via DIP switches | |
Labeling | space for labeling at the front |
Electromagnetic compatibility | |||||
|
Electromagnetic compatibility | NE 21:2006 For further information see system description. | |
Degree of protection | IEC 60529:2001 | |
Protection against electrical shock | UL 61010-1 |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Degree of protection | IP20 | ||||||||||
Mass | approx. 100 g | ||||||||||
Dimensions | 12.5 x 106 x 128 mm (0.5 x 4.2 x 5.1 inch) (W x H x D) | ||||||||||
| |||||||||||
Mounting | on termination board | ||||||||||
Coding | pin 2, 3 and 4 trimmed For further information see system description. |
EU-type examination certificate | BASEEFA 10 ATEX 0031X | |||||||||||||
| ||||||||||||||
Supply | ||||||||||||||
| ||||||||||||||
Certificate | BASEEFA 10 ATEX 0032X | |||||||||||||
| ||||||||||||||
Galvanic isolation | ||||||||||||||
| ||||||||||||||
Directive conformity | ||||||||||||||
|
UL approval | ||||||||
| ||||||||
IECEx approval | ||||||||
|