1 axis acceleration sensor, E1-Type approval, Analog output 4 mA ... 20 mA, Fixed evaluation limits , High shock resistance, Teachable zero point, Measuring range -2 g ... +2 g, Increased noise immunity 100 V/mfa
2 axis acceleration sensor, E1-Type approval, Analog output 4 mA ... 20 mA, Fixed evaluation limits , High shock resistance, Teachable zero point, Measuring range -2 g ... +2 g, Increased noise immunity 100 V/mfa
Not available for purchase: For 8 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Hazardous area: screw terminals, blue, Non-hazardous area: screw terminals, black, Number of modules: 8, Number of channels per module: 2 , 4, Signal type: Universal, Manufacturer: Universal, Control system type: Universalpa
Not available for purchase: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Not available for purchase: 1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 26.5 V DC, non-polarized, Relay contact output for de-energized to safe function, Test pulse immunity, Up to SIL 3 acc. to IEC/EN 61508, Up to PL e acc. to EN/ISO 13849, Housing width: 12.5 mm, Number of channels: 1-channel, DTS function (de-energized to safe), Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC loop powered, Type: 1 x logic inputpa
Not available for purchase: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Not available for purchase: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Not available for purchase: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
Not available for purchase: 1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 20 V DC ... 26.5 V DC, non-polarized, Fail-safe relay contact output for de-energized and energized to safe function , Test pulse immunity, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, ETS function (energized to safe), DTS function (de-energized to safe), DPS function (dual pole switching), Safety Integrity Level (SIL): SIL 3pa
Not available for purchase: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Not available for purchase: Surge protection for 2 supply lines, Type 3 acc. to EN 61643-11, Nominal voltage 120 V AC, Pre-wired unit, Operating state and fault indication of every protected line, Fault indication output, DIN rail mountable, Device type: type 3 acc. to EN 61643-11:2013 class III acc. to IEC 61643-1:2011, Number of protected supply lines: 2pa
From the batterycell to the batterymodule to the batterypack: Pepperl+Fuchsofferspowerfulsensortechnology for automatedbatteryproduction ... sensorsolutions for yourproductionprocess. For example, the visionsensorSmartRunnerExplorer3-Dgenerates a high-resolution3-Dpointcloud of the batterymodule. This datacan be analyzedusingpatternrecognitionalgorithms, enablingfully ...
Interfacetechnology from Pepperl+Fuchsoffers a widerange of components and solutions for hazardousareaapplications in processíndustries ... are subject to SIL3requirements. SIL3currentdrivers for intrinsicallysafesignalsmakecomplexworkaroundsimplementingredundancyviatwoSIL2controlcircuits a thing of the past. MainApplicationsThermalPowerPlants: Direction of Rotation ...
The WCS is designed for applications with extremeambient conditions or especiallylongdistances ... PositionEncodingSystem | WCSWCSBenefitsModularDesignWCSVarietiesCodeRails and ID-PadsMountingSystemsApplicationsContact The absolutebenchmark. Provensystem with maximumprecision – even in extremeweather, dirt, and harsh ...
Learn more about the safeabsolutelinearpositioningsystems from Pepperl+Fuchs for safetyapplicationsup to SIL3 and PLe ... , and mechanicalstress. The safeWCS/PUSpositioningsystemmakessafeabsolutepositioningup to SIL3/PLeeven in such harshenvironmental conditions possible. With itsrobustoutdoorprotectivehousing with IP69degree of protection, it is sealedagainst ...
Get an overview of Pepperl+Fuchs' broadportfolio of HMIsystems for processindustries ... includesHMIsystems, panel and boxPCs. The modularityallowsthinclient and displayunits or powersupplies to be easilyreplaceddirectly in the field. VisuNetFLXEdge The VisuNetFLXEdgeseriesprovidesusers with an all-weatheroperatorstation ...
Besidestried-and-testedfunctions, the Tab-Ex® tabletscome with innovativefeatureslike the integration of augmentedrealityapplications that makeIndustry40/IIoTapplicationseasy to implement ... highdatathroughput and lowlatency, whereas5G and Wi-Fi® 6Econnectivityprovide the latest in dataspeeds and functionality. Tab-Ex® 03 The rugged, highlysecure and hazardousarea-ratedtabletTab-Ex® 03continues the successstory with the 3rd ...
Pepperl+Fuchs’ LoRaWANbasedultrasonicsensorWILSEN is a sturdysolution for filllevelmonitoring and distancemeasurement ... , you canfind a compactstep-by-stepguide on ourwebsite as well. Services for YourSuccessUltrasonicsensors from Pepperl+Fuchs are built in ourowntechnologycenter , wheretransducerdevelopment and manufacturingtakeplace. For more than30years ...
Pepperl+Fuchs’ industrialboxthinclients are designed to deliver a reliable and ruggedvirtualizationsolution for the harsh conditions in industrialenvironments ... ProcessorAMDRyzenEmbeddedV1202BIntel® Atomx6413ERAM4GBDDR4 (Standard) 8GBDDR4 (optional) 8GBDDR4HousingAluminumChassisAluminumChassisIPRatingIP4xIP4xOperatingTemperatureIndustrialtemperaturerange: 0 ... 55 °C (32 ... 131 °F) Wide ...
SmartRunner3-D is the latest3-Dvisionsensoravailable with time of flight and stereovisiontechnologyLearn more about it ... , allowingeasierinterpretation of the measurementresults. Oncealladjustments are made, a 3-Dpointcloudimage is created. In this way, the stereovisiontechnologycan be used to generateextremelyprecise, high-resolutionimagesover the entire ...
IndustrialFMCWradarsensors from Pepperl+Fuchsfeature a high-readrange and are ideallysuited for integration into mobilemachines ... -relevantapplications in conjunction with a fail-safePLC, achieving a safetylevel of PLcCat. 2 with just one sensor. The parameterization of the radarsensors is alsodonveconvenientlyvia the well-knownconfigurationtoolPACTware . Here, both a COM ...
1-10/926Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.