Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
Product Description |
---|
Vibration sensor with analog current output, increased temperature resistance, suitable up to Zone 1/21 with type of protection explosionproof enclosure |
General specifications | ||
---|---|---|
Type | Vibration sensor | |
Measuring technology | MEMS | |
Series | Performance Plus Line | |
Measured variable | Vibration velocity | |
Measuring range | ||
Vibration velocity | 0 ... 32 mm/s | |
Measurement accuracy | ± 0.1 mm/s (calibration point: 90% of the measuring range; 159.2 Hz) Complies with the tolerance requirements of DIN ISO 2954 for measuring range greater than 8 mm/s |
|
Cross-sensitivity | < 5 % of the partial lateral acceleration, which acts exactly 90° to the measuring axis | |
Frequency range | 10 ... 1000 Hz | |
Averaging time | for v-rms: 2 s | |
Electrical specifications | ||
Fusing | external fuse is required: 3 A , semi-time-lag , 30 V DC | |
Operating voltage | 10 ... 30 V DC | |
Current consumption | max. 25 mA | |
Power consumption | max. 750 mW | |
Time delay before availability | 10 s (rms filter is calculated intially with measurement data before they are available at the output) | |
Surge protection | up to 2 kV | |
Output 1 | ||
Output type | analog output, current output of the vibration variable |
|
Output current | 4 ... 20 mA | |
Load resistor | ≤ 500 Ω | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP66, IP67 | |
Shock resistance | DIN EN 60068-2-27, 60 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 16.5 g, 10 ... 1000 Hz | |
Vibration evaluation | DIN ISO 10816/20816 | |
Approvals and certificates | ||
IECEx approval | ||
Equipment protection level Gb | IECEx CSAE 22.0042X | |
Equipment protection level Db | IECEx CSAE 22.0042X | |
ATEX approval | ||
Equipment protection level Gb | CSANe 21 ATEX 1074 X | |
Equipment protection level Db | CSANe 21 ATEX 1074 X | |
Ambient conditions | ||
Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) | |
Measuring head temperature | -40 ... 125 °C (-40 ... 257 °F) directly at the mounting point | |
Storage temperature | -40 ... 60 °C (-40 ... 140 °F) | |
Mechanical specifications | ||
Connection type | cable | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Degree of protection | IP66 / IP67 only in connected state | |
Cable | ||
Number of cores | 4 | |
Core cross section | 0.34 mm2 | |
Length | 5 m | |
Tension force | max. 80 N (tensile loading directly at the cable, not at the metal conduit if attached) | |
Mass | 460 g | |
Dimensions | ||
Length | 82.35 mm | |
Diameter | 31 mm | |
General information | ||
Use in the hazardous area | see instruction manuals Only use accessories specified by the manufacturer. |
System | Classcode |
---|---|
ECLASS 13.0 | 27271103 |
ECLASS 12.0 | 27201406 |
ECLASS 11.0 | 27201406 |
ECLASS 10.0.1 | 27201406 |
ECLASS 9.0 | 27201406 |
ECLASS 8.0 | 27201406 |
ECLASS 5.1 | 27201406 |
ETIM 9.0 | EC004309 |
ETIM 8.0 | EC004309 |
ETIM 7.0 | EC002959 |
ETIM 6.0 | EC002959 |
ETIM 5.0 | EC001758 |
UNSPSC 12.1 | 41114624 |
The vibration sensor determines the vibration quantity using rms (root meas square) averaging. This form of quadratic averaging or pre-filtering enables precise trend statements about the condition of the application.
The sensor’s design is impressively robust against tough environmental conditions.
The stainless steel housing provides optimal protection against corrosion. The wide temperature range of the sensor enables reliable measured values even in harsh conditions.
Furthermore there is an approval for the use of the sensor in hazardous areas.
The simple mounting allows for commissioning in any application.
Literature | Language | File Type | File Size |
---|---|---|---|
Product Overview - Vibration Sensors | ENG | 1351 KB |
Safety and Security Documentation | Language | File Type | File Size |
---|---|---|---|
Instruction manual | ENG | 156 KB | |
Manuals | |||
Manual VIM6*-Vibration Sensors | ENG | 2498 KB |
CAD | Language | File Type | File Size |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 899 KB |
CAE | |||
CAE EPLAN Data Portal / CAE EPLAN Data Portal | ALL | LINK | --- |
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZ | ALL | EDZ | 117 KB |
Certificates | Certificate No. | Language | File Type | File Size |
---|---|---|---|---|
Europe CSA ATEX Category 2 | CSANe 22 ATEX 1074 X | ALL | 1221 KB | |
Worldwide IECEx Certificate of Conformity | IECEx CSAE 22.0042X | ALL | LINK | --- |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-6808 | ALL | 332 KB | |
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F) | DOC-6850 | ALL | 326 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|