Vibration sensor VIM32PL-E1V64-0RE-I421V14

VIM32PL-E1V64-0RE-I421V14
  • Analog current output
  • Screw-in thread for simple installation
  • Simple electrical commissioning
  • Rugged stainless steel housing
  • Vibration velocity in mm/s (rms) acc. to DIN ISO 10816/20816
  • Switching output

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  VIM32PL-E1V64-0RE-I421V14

Product Description
Vibration sensor with switching output and analog current output
General specifications
TypeVibration sensor
Measuring technologyMEMS
SeriesPerformance Line
Measured variableVibration velocity
Measuring range
Vibration velocity0 ... 64 mm/s
Measurement accuracy± 0.1 mm/s (calibration point: 90% of the measuring range; 159.2 Hz)
Complies with the tolerance requirements of DIN ISO 2954 for measuring range greater than 8 mm/s
Cross-sensitivity< 5 % of the partial lateral acceleration, which acts exactly 90° to the measuring axis
Frequency range10 ... 1000 Hz
Averaging timefor v-rms: 2 s
Functional safety related parameters
MTTFd329 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Electrical specifications
Fusingexternal fuse is required: 1 A , fast acting , 30 V DC
Operating voltage18 ... 30 V DC
Current consumptionmax. 220 mA
Power consumptionmax. 6.6 W
Time delay before availability2 s (rms filter is calculated intially with measurement data before they are available at the output)
Surge protectionup to 2 kV
Output 1
Output typeanalog output, current
output of the vibration variable
Output current4 ... 20 mA
Load resistor≤ 500 Ω
Output 2
Output typePNP
Switching functionNormally closed (NC)
Operating current≤ 100 mA
Voltage drop< 2 V
Switching threshold6.4 mm/s ( 10 % of the measuring range )
Preset response time2 s (minimum time for a vibration event above the switching threshold so that the output switches)
Short-circuit protectionyes
Standard conformity
Degree of protectionDIN EN 60529, IP66, IP67
Shock resistanceDIN EN 60068-2-27, 60 g, 6 ms
Vibration resistanceDIN EN 60068-2-6, 16.5 g, 10 ... 1000 Hz
Vibration evaluationDIN ISO 10816/20816
Approvals and certificates
UL approval
Ordinary LocationE468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only.
adapters providing field wiring on request
Maximum permissible ambient temperaturemax. 80 °C (max. 176 °F)
Ambient conditions
Ambient temperature-40 ... 85 °C (-40 ... 185 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection typeplug
Housing materialStainless steel 1.4305 / AISI 303
Degree of protectionIP66 / IP67 only in connected state
Connector
ThreadingM12
Number of pins4
Massapprox. 100 g
Dimensions
Length72.5 mm
Diameter23.8 mm

Classifications

SystemClasscode
ECLASS 13.027271103
ECLASS 12.027201406
ECLASS 11.027201406
ECLASS 10.0.127201406
ECLASS 9.027201406
ECLASS 8.027201406
ECLASS 5.127201406
ETIM 9.0EC004309
ETIM 8.0EC004309
ETIM 7.0EC002959
ETIM 6.0EC002959
ETIM 5.0EC001758
UNSPSC 12.141114624

Details: VIM32PL-E1V64-0RE-I421V14

Function

The vibration sensor determines the vibration quantity using rms (root meas square) averaging. This form of quadratic averaging or pre-filtering enables precise trend statements about the condition of the application.

In addition, a switching output with preset switching characteristics is included. This means a permanent monitoring of the vibration measured value is not required, because a necessary maintenance of the plant is signalized directly. The switching characteristics are provided with a preset response time. Thus, the output is only set if the vibration event lasts longer than this time. Short-time vibration events are hence filtered out.

The simple mounting allows for commissioning in any application.

Informative Literature: VIM32PL-E1V64-0RE-I421V14

Language Selection:
LiteratureLanguageFile TypeFile Size
Product Overview - Vibration SensorsENGPDF1351 KB
Application Report - Servicing Mobile Concrete Mixers According to Actual NeedsENGPDF169 KB

Product Documentation: VIM32PL-E1V64-0RE-I421V14

Language Selection:
Brief InstructionsLanguageFile TypeFile Size
Instruction leaflet / BeipackzettelALLPDF252 KB
Safety and Security Documentation
Instruction manualENGPDF151 KB
Manuals
Manual VIM3* Vibration SensorsENGPDF1870 KB

Design / Simulation: VIM32PL-E1V64-0RE-I421V14

Language Selection:
CADLanguageFile TypeFile Size
CAD 3-D / CAD 3-DALLSTP2534 KB

Approvals: VIM32PL-E1V64-0RE-I421V14

Language Selection:
CertificatesCertificate No.LanguageFile TypeFile Size
Canada, USA UL Ordinary LocationE468231ALLPDF610 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-5656AALLPDF449 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)DOC-5657AALLPDF255 KB

Associated Products: VIM32PL-E1V64-0RE-I421V14

Accessories
Mounting adapter for VIM3*/VIM6*/VIM8* vibration sensors, internal thread M8 x 1.25 x 10, external thread M8 x 1.25, screw-in depth 19.5fa
Mounting adapter for VIM3*/VIM6* vibration sensors, internal thread M8 x 1.25 x 10, external thread M10 x 1.5, screw-in depth 18fa
Mounting adapter for VIM3*/VIM6*/VIM8* vibration sensors, internal thread M8 x 1.25 x 10, external thread M30 x 3.5, screw-in depth 45fa
Protective rubber sleeve for VIM3* vibration sensors against ingress of moisture and mechanical effectsfa
Mounting adapter for VIM3*/VIM6* vibration sensors, internal thread M8 x 1.25 x 10, external thread NPT1/2", screw-in depth 24fa
EMC adapter for VIM3*/VIM6* vibration sensors, internal thread M8 x 1.25 x 10, external thread M8 x 1.25, screw-in depth 8fa
Female cordset single-ended M12 straight A-coded, 4-pin, PUR cable black, shielded, UL approved, drag chain suitablefa
Female cordset single-ended M12 straight A-coded, 4-pin, PUR cable black, shielded, UL approved, drag chain suitablefa
Female cordset single-ended M12 straight A-coded, 4-pin, PUR cable black, shielded, UL approved, drag chain suitablefa
Mounting adapter for VIM3*/VIM6* vibration sensors, internal thread M8 x 1.25 x 10, external thread M6 x 1.0, screw-in depth 10fa
Mounting adapter for VIM3*/VIM6* vibration sensors, internal thread M8 x 1.25 x 10, external thread M10 x 1.5, screw-in depth 18fa
Mounting adapter for VIM3*/VIM6*/VIM8* vibration sensors, internal thread M8 x 1.25 x 10, external thread M16 x 2.0, screw-in depth 27fa
Mounting adapter for VIM3*/VIM6*/VIM8* vibration sensors, internal thread M8 x 1.25 x 10, external thread M20 x 2.5, screw-in depth 34fa
Mounting adapter for VIM3*/VIM6*/VIM8* vibration sensors, internal thread M8 x 1.25 x 10, external thread M24 x 3.0, screw-in depth 40fa
Magnetic adapter for VIM3*/VIM6* vibration sensors, internal thread M8 x 1.25 x 10, holding force 35 kgfa
IO-Link converter with analog input (current/voltage)fa