Serviceline Industrial Sensors
Sales phone: 0161 622 6308
Tech phone: 0161 622 6311
Fax: 0161 624 6537
Serviceline Explosion Protection
Sales phone: 0161 622 6309
Tech phone: 0161 622 6313
Fax: 0161 624 6537

Capacitive sensor CCN5-F46A-E2

CCN5-F46A-E2
  • 5 mm non-flush
  • 3-wire DC
  • Flat housing
  • Chemically resistant PVDF housing
  • Mounting slots for cable ties
  • Degree of protection IP68
  • Thru-holes for screw mounting

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  CCN5-F46A-E2

General specifications
Switching functionNormally open (NO)
Output typePNP
Rated operating distance5 mm
Installationnon-flush
Output polarityDC
Assured operating distance0 ... 3.5 mm
Output type3-wire
Nominal ratings
Installation conditions
B0 mm
C10 mm
F20 mm / 50 mm
Operating voltage10 ... 30 V DC
Switching frequency0 ... 10 Hz
Hysteresis1 ... 10 typ. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionpulsing
Voltage drop≤ 2 V
Operating current0 ... 100 mA
Lowest operating current0 mA
Off-state current0 ... 0.5 mA typ. 0.01 mA
Off-state current TU =40 °C, switching element off≤ 100 µA
No-load supply current≤ 15 mA
Time delay before availability≤ 50 ms
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd672 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
StandardsEN IEC 60947-5-2
Approvals and certificates
UL approvalcULus Listed, General Purpose, Class 2 Power Source
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection typecable FEP , 2 m
Core cross section0.14 mm2
Housing materialPVDF
Sensing facePVDF
Degree of protectionIP68
Dimensions
Height10.5 mm
Width50 mm
Length30.4 mm
Notecable tensile strength 20 N

Classifications

SystemClasscode
ECLASS 13.027274201
ECLASS 12.027274201
ECLASS 11.027270102
ECLASS 10.0.127270102
ECLASS 9.027270102
ECLASS 8.027270102
ECLASS 5.127270102
ETIM 9.0EC002715
ETIM 8.0EC002715
ETIM 7.0EC002715
ETIM 6.0EC002715
ETIM 5.0EC002715
UNSPSC 12.139121550

Details: CCN5-F46A-E2

Product Documentation: CCN5-F46A-E2

Language Selection:
Product informationLanguageFile TypeFile Size
Installation conditionsENGPDF219 KB

Design / Simulation: CCN5-F46A-E2

Language Selection:
CADLanguageFile TypeFile Size
CAD 3-D / CAD 3-DALLSTP117 KB
CAD Portal / CAD PortalALLLINK---
CAE
CAE EPLAN Data Portal / CAE EPLAN Data PortalALLLINK---
EPLAN macro EDZ / EPLAN Makro EDZALLEDZ60 KB

Approvals: CCN5-F46A-E2

Language Selection:
CertificatesCertificate No.LanguageFile TypeFile Size
Canada USA UL Ordinary LocationUL-US-L87056-11-41301991-3 / UL-CA-L87056-31-41301991-3ALLPDF1806 KB
China Information on CCCCCC-Exempt Declaration (Pepperl+Fuchs)ALLPDF457 KB
Declaration of Conformity
EU Declaration of Conformity (P+F)TDOC-7834_ENGENGPDF1309 KB
UK Declaration of Conformity (P+F)TDOC-7835_ENGENGPDF1285 KB