Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
Product Description |
---|
Fieldbus diagnostic handheld for comprehensive diagnostics of the fieldbus physical layer |
General specifications | ||
---|---|---|
Design / Mounting | Handheld/mobile | |
Installation in hazardous area | Zone 1 / Div. 1 | |
Supply | ||
Connection | Fieldbus , Battery , 9V 6LR61 block, type alkaline, carbon-zinc, lithium iron disulfide, nickel-cadmium, nickel-metal hydride, or rechargeable lithium , USB | |
Fieldbus connection | ||
Fieldbus type | FOUNDATION Fieldbus/PROFIBUS PA | |
Rated voltage | 8.5 ... 35 V | |
Rated current | ... 10 mA , if bus powered | |
Indicators/operating means | ||
Display | LC display | |
Keypad | Membrane 8 keys | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
Standard conformity | ||
Electromagnetic compatibility | NE 21:2011 | |
Degree of protection | IEC 60529 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Software | ||
Languages | English (default), German (optional), Portuguese (optional), | |
Ambient conditions | ||
Ambient temperature | -20 ... 50 °C (-4 ... 122 °F) | |
Storage temperature | -20 ... 70 °C (-4 ... 158 °F) | |
Relative humidity | < 95 % non-condensing | |
Shock resistance | 15 g , 11 ms | |
Vibration resistance | 1 g , 10 ... 150 Hz | |
Mechanical specifications | ||
Connection type | Fieldbus: Cable with test clips and cable with test plugs, 2.5 mm Trigger output: Cable with 2 banana plugs USB: Square type B socket |
|
Degree of protection | IP44 | |
Mass | 500 g | |
Data for application in connection with hazardous areas | ||
EU-type examination certificate | ZELM 14 ATEX 0531 | |
Marking | II 2(1) G Ex ib [ia Ga] IIC T4 Gb , II 3(1) G Ex ic [ia Ga] IIC T4 Gc , II 3 G Ex ic IIC T4 Gc , II (1) D [Ex ia IIIC Da] , II (3) D [Ex ic IIIC Dc] |
|
Bus | ||
Type | Fieldbus | |
Type of protection | ia, ib | |
Internal capacitance | < 1.8 nF | |
Internal inductance | < 1.5 µH | |
Voltage | 30 V | |
Bus | ||
Type | Fieldbus | |
Type of protection | ic | |
Internal capacitance | < 1.8 F | |
Internal inductance | < 1.5 µH | |
Voltage | 35 V | |
Outputs | ||
Type | Trigger output | |
Maximum safe voltage | 140 V | |
Interface | ||
Type | USB interface | |
Maximum safe voltage | 253 V | |
Voltage | 6 V | |
Directive conformity | ||
Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 | |
International approvals | ||
CSA approval | CSA 16.70029275 | |
Approved for | Class I, Division 2, Groups A, B, C, D, T4 Associated equipment for Class I, Division 1, Groups A, B, C, D Associated equipment for Class II, Division 1, Groups E, F, G Associated equipment for Class III, Division 1 |
|
IECEx approval | IECEx ZLM 14.0012 | |
Approved for | Ex ib [ia Ga] IIC T4 Gb , Ex ic [ia Ga] IIC T4 Gc , Ex ic IIC T4 Gc , [Ex ia IIIC Da] , [Ex ic IIIC Dc] |
|
General information | ||
Scope of delivery | FDH-1 incl. carrying case, fieldbus connection cable, USB 2.0 cable, FDH-1 Manager software | |
Supplementary information | Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
System | Classcode |
---|---|
ECLASS 13.0 | 27242692 |
ECLASS 12.0 | 27242692 |
ECLASS 11.0 | 27242692 |
ECLASS 10.0.1 | 27242692 |
ECLASS 9.0 | 27242692 |
ECLASS 8.0 | 27242692 |
ECLASS 5.1 | 27242692 |
ETIM 9.0 | EC001604 |
ETIM 8.0 | EC001604 |
ETIM 7.0 | EC001604 |
ETIM 6.0 | EC001604 |
ETIM 5.0 | EC001604 |
UNSPSC 12.1 | 39121008 |
The FieldConnex ® Fieldbus Diagnostic Handheld FDH‑1 is a comprehensive measurement and commissioning tool. The handheld can be connected to any point of a segment. Via display and push buttons, FDH‑1 guides the user through many scenarios of testing. FDH‑1 can record and store data for up to 32 segments with maximum device count without requiring a connection to a PC.
FDH‑1 supports inexperienced and expert users alike through different operating modes. Failure margin checks and device coupler tests help set up the optimum condition of the fieldbus infrastructure and find weak spots in the installation. The expert system and wizards enable easy handling and require little or no training. FDH‑1 supports multiple languages that can be downloaded onto the handheld.
FDH‑1 Manager Software Premium can operate the handheld with enhanced visualization. The software loads data from FDH‑1 and saves data back, to allow for comparisons between actual and planned physical layer attributes.
Literature | Language | File Type | File Size |
---|---|---|---|
Application Report - Controlling and Monitoring liquid Helium at the Deutsches Elektronen-Synchrotron | ENG | 361 KB | |
Application Report - Digital Communication in Steel-Plate Manufacturing | ENG | 470 KB |
Safety and Security Documentation | Language | File Type | File Size |
---|---|---|---|
Instruction manual | ENG | 230 KB | |
Manuals | |||
Manual | ENG | 15354 KB | |
Software Information | |||
Release Note | ENG | 409 KB |
Certificates | Certificate No. | Language | File Type | File Size |
---|---|---|---|---|
Canada, USA CSA | CSA 16.70029275 | ALL | 162 KB | |
China SITIIAS CCC Ex Certificate | 2020322310003511 (Singapore) | ALL | 1165 KB | |
Europe ZELM ATEX | ZELM 14 ATEX 0531 | ALL | 778 KB | |
Worldwide ZELM IECEx Certificate of Conformity | IECEx ZLM 14.0012 | ALL | LINK | --- |
Control Drawings | ||||
Control drawing CSA / Control drawing CSA | ALL | 281 KB | ||
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-1076D | ALL | 1041 KB |
Software Tools | Release Info | File Type | File Size |
---|---|---|---|
FDH-1 Manager / FDH-1 Manager | 1.0.3.1144 | ZIP | 52320 KB |
Get your free ADM Integration Package for your DCS System!
ABB 800xA Integration Package Download