Serviceline Industrial Sensors
Sales phone: 0161 622 6308
Tech phone: 0161 622 6311
Fax: 0161 624 6537
Serviceline Explosion Protection
Sales phone: 0161 622 6309
Tech phone: 0161 622 6313
Fax: 0161 624 6537

Network Technology (Ex e, Ex nR, Ex op)

Choose your product

Next PageLast Page
Product

Safe protection of fiber optic cable splices in hazardous areas, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Ex op pr and Ex tb certified , Carbon loaded, antistatic glass-fiber reinforced polyester, 179 mm x 359 mm x 104 mm, Modern design with high impact resistance, Easy installation due to easily accessible mounting points, Easy cover opening without damage due to mulitple pry points, Left side cable gland polyamide, 4x M20; right side cable gland polyamide, 4x M20, Explosion protection: Ex epa

Safe protection of fiber optic cable splices in hazardous areas, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Ex op pr and Ex tb certified , Carbon loaded, antistatic glass-fiber reinforced polyester, 179 mm x 359 mm x 104 mm, Modern design with high impact resistance, Easy installation due to easily accessible mounting points, Easy cover opening without damage due to mulitple pry points, Left side cable gland polyamide, 6x M20; right side cable gland polyamide, 6x M20, Explosion protection: Ex epa

Safe protection of fiber optic cable splices in hazardous areas, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Ex op pr and Ex tb certified , Carbon loaded, antistatic glass-fiber reinforced polyester, 179 mm x 359 mm x 104 mm, Modern design with high impact resistance, Easy installation due to easily accessible mounting points, Easy cover opening without damage due to mulitple pry points, Left side cable gland polyamide, 1x M20; right side cable gland polyamide, 1x M20, Explosion protection: Ex epa

Safe protection of fiber optic cable splices in hazardous areas, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Ex op pr and Ex tb certified , Carbon loaded, antistatic glass-fiber reinforced polyester, 179 mm x 359 mm x 104 mm, Modern design with high impact resistance, Easy installation due to easily accessible mounting points, Easy cover opening without damage due to mulitple pry points, Left side cable gland polyamide, 2x M20; right side cable gland polyamide, 2x M20, Explosion protection: Ex epa

Safe protection of fiber optic cable splices in hazardous areas, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Ex op pr and Ex tb certified , Carbon loaded, antistatic glass-fiber reinforced polyester, 179 mm x 359 mm x 166 mm, Modern design with high impact resistance, Easy installation due to easily accessible mounting points, Easy cover opening without damage due to mulitple pry points, Left side cable gland polyamide, 8x M20; right side cable gland polyamide, 8x M20, Explosion protection: Ex epa

Safe protection of fiber optic cable splices in hazardous areas, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Ex op pr and Ex tb certified , Stainless Steel AISI 316L, 1 splice tray, 12 fusion-type splices per tray, Explosion protection: Ex e, Enclosure: 1.5 mm AISI 316L, (1.4404) stainless steelpa

Safe protection of fiber optic cable splices in hazardous areas, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Ex op pr and Ex tb certified , Stainless Steel AISI 316L, 2 splice trays, 12 fusion-type splices per tray, Explosion protection: Ex e, Enclosure: 1.5 mm AISI 316L, (1.4404) stainless steelpa

Safe protection of fiber optic cable splices in hazardous areas, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Ex op pr and Ex tb certified , Stainless Steel AISI 316L, 3 splice trays, 12 fusion-type splices per tray, Explosion protection: Ex e, Enclosure: 1.5 mm AISI 316L, (1.4404) stainless steelpa

Safe protection of fiber optic cable splices in hazardous areas, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Ex op pr and Ex tb certified , Stainless Steel AISI 316L, 4 splice trays, 12 fusion-type splices per tray, Explosion protection: Ex e, Enclosure: 1.5 mm AISI 316L, (1.4404) stainless steelpa

Safe protection of fiber optic cable splices in hazardous areas, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Ex op pr and Ex tb certified , Stainless Steel AISI 316L, 5 splice trays, 12 fusion-type splices per tray, Explosion protection: Ex e, Enclosure: 1.5 mm AISI 316L, (1.4404) stainless steelpa
Next PageLast Page