Temperature Converter S1SD-1TI-1U

S1SD-1TI-1U
  • 1-channel signal conditioner
  • 24 V DC supply
  • Thermocouple, RTD, potentiometer or mV input
  • Input for PTC thermistor
  • Current and voltage output
  • Line fault (LFD) and sensor burnout detection
  • Accuracy 0.1 %
  • Connection via screw terminals

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  S1SD-1TI-1U

General specifications
Signal typeAnalog input
Operation timeMTBF: 353 a acc. to SN 29500
stationary continuous operating, average ambient temperature 40 °C (104 °F)
Supply
ConnectionPower Bus or terminals 1-, 2+
Rated voltage16.8 ... 31.2 V DC
Power dissipation0.7 W
Power consumption0.8 W
Interface
Programming interfaceprogramming socket
Input
Connection sidefield side
Connectionterminals 5, 6, 7, 8
PTCtype KT, KTY, ST
Measuring currentapprox. 200 µA
Types of measuring2-, 3-, 4-wire connection
Lead resistance≤ 100 Ω per line
Measurement loop monitoringsensor breakage, lead breakage, short circuit
RTDtype Pt100, Pt200, Pt500, Pt1000 (EN 60751:1995)
type Ni100, Ni200, Ni500, Ni1000 (DIN 43760)
Measuring currentapprox. 200 µA
Types of measuring2-, 3-, 4-wire connection
Lead resistancemax. 100 Ω per line
Measurement loop monitoringsensor breakage, lead breakage, short circuit
Thermocouplestype B, E, J, K, N, S, T (IEC 584-1:1995)
type L, U (DIN 43710:1985)
type C, D (ASTM E988)
Cold junction compensationexternal (Pt100) and internal , manually
Lead resistancemax. 10 kΩ
Measurement loop monitoringsensor breakage, lead breakage
Resistor
Measuring range0 ... 5 kΩ
Potentiometer0.2 ... 50 kΩ
Types of measuring3-wire connection
Voltage-100 ... 100 mV
-1000 ... 1000 mV
Input resistance≥ 1 MΩ
Output
Connection sidecontrol side
Connectionterminals 3-, 4+
Analog voltage output0/1 ... 5 V , 0/2 ... 10 V , load ≥ 2 kΩ
Analog current output0/2 ... 10 mA, 0/4 ... 20 mA, load ≤ 600 Ω
Ripple≤ 10 mV eff
Fault signaldownscale or upscale
Transfer characteristics
Accuracymax. 0.1 % of full-scale value
Measuring time≤ 300 ms
Deviation
RTD< 0.1 K/0.05 % of the measured value
Thermocouples< 0.3 K/0.1 % of the measured value
Voltage< 0.1 % of the measured value
Potentiometer< 0.02 % of the measured value
Influence of ambient temperature< 100 ppm/K of full-scale value
Galvanic isolation
Output/power supplysafe electrical isolation by reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff test voltage 3 kV, 50 Hz, 1 min
Input/Other circuitssafe electrical isolation by reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff test voltage 3 kV, 50 Hz, 1 min
Indicators/settings
Control elementsDIP switch
keys
Configurationvia DIP switches
via keys
via software
Labelingspace for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Conformity
Degree of protectionIEC 60529:2001
Protection against electrical shockEN 61010-1:2010
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Degree of protectionIP20
Connectionscrew terminals
Core cross section0.5 ... 2.5 mm2 (20 ... 14 AWG)
Massapprox. 70 g
Dimensions6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) (W x H x D) , housing type S1
Height97 mm
Width6.2 mm
Depth107 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
CertificateDEMKO 16 ATEX 1750X
MarkingEx-Hexagon II 3G Ex nA IIC T4 Gc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-15:2010
International approvals
UL approvalE106378
IECEx approval
IECEx certificateIECEx UL 16.0116X
IECEx markingEx nA IIC T4 Gc
General information
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027210129
ECLASS 12.027210129
ECLASS 11.027210129
ECLASS 10.0.127210129
ECLASS 9.027210129
ECLASS 8.027210190
ECLASS 5.127210107
ETIM 9.0EC002919
ETIM 8.0EC002919
ETIM 7.0EC002919
ETIM 6.0EC002919
ETIM 5.0EC001485
UNSPSC 12.132101514

Details: S1SD-1TI-1U

Function

This signal conditioner provides the galvanic isolation between field circuits and control circuits.

The device has an input for signals of the following field devices:
- resistance thermometers
- thermocouples
- PTC thermistors
- potentiometers
- voltage sources
- field device with its own characteristic

The device provides the following standard signals at the output:
- 0/2 mA ... 10 mA signal
- 0/4 mA ... 20 mA signal
- 0/1 V ... 5 V signal
- 0/2 V ... 10 V signal

This device has an integrated cold junction compensation. You can also implement external cold junction compensation.

A fault is signalized by LEDs.

The device is easily configured by the use of DIP switches.

The Teach-In function can be used to teach in the potentiometer start value and end value.

The device can be powered via terminals or Power Bus.

Informative Literature: S1SD-1TI-1U

Language Selection:
LiteratureLanguageFile TypeFile Size
Application Report - Sand Trap and Preliminary Sedimentation StageENGPDF448 KB
Product Overview SC-SystemENGPDF456 KB
Tender text
Tender textENGD818 KB

Product Documentation: S1SD-1TI-1U

Language Selection:
Brief InstructionsLanguageFile TypeFile Size
Brief instructionsENGPDF282 KB
Safety and Security Documentation
Instruction manualENGPDF136 KB
Manuals
System ManualENGPDF2706 KB

Design / Simulation: S1SD-1TI-1U

Language Selection:
CADLanguageFile TypeFile Size
CAD 3-D / CAD 3-DALLSTP4814 KB
CAD Portal / CAD PortalALLLINK---
CAE
CAE EPLAN Data Portal / CAE EPLAN Data PortalALLLINK---
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZALLEDZ97 KB
EPLAN macros SC-System devices (EDZ) / EPLAN-Makros SC-System-Geräte (EDZ)ALLZIP4082 KB

Approvals: S1SD-1TI-1U

Language Selection:
CertificatesCertificate No.LanguageFile TypeFile Size
Canada UL cULE106378 cUL (QUZW7)ALLLINK---
Europe DEMKO ATEX Category 3 GDEMKO 16 ATEX 1750XALLPDF1876 KB
UL Non-Sparking nA IECEx Certificate of ConformityIECEx UL 16.0116XALLLINK---
USA ULE106378 UL (QUZW)ALLLINK---
Declaration of Conformity
EU Declaration of Conformity (P+F)TDOC-0534EENGENGPDF180 KB

Software: S1SD-1TI-1U

Language Selection:
Device Description Files/DriversRelease InfoFile TypeFile Size
DTM for S1SD-1TI-1U / DTM für S1SD-1TI-1UZIP---
Software Tools
Configuration software for SC-System: SC-Config / Konfigurations Software für SC-System: SC-Config3.4.0ZIP---
PACTware 4.1 SP6 / PACTware 4.1 SP64.1.0.53ZIP43327 KB
PACTware 5.0 / PACTware 5.05.0.5.31ZIP44203 KB

Associated Products: S1SD-1TI-1U

Matching System Components
Interface for Power Bus, Supply current 3 A, LED status indication, Connection via screw terminalspa
For SC-System, Free of charge, Internet download possiblepa
Isolated USB interface cable, Used with SC-System devices, Configurable via PCpa
Universal DTM host platform, For all DTMs of Pepperl+Fuchs, Approved FDT/DTM technology, Free of charge, Download from Pepperl+Fuchs websitepa
Bus carrier with bus PCB for 35 mm DIN mounting rail, height 7.5 mm, Provides DC supply voltage and the bus connection to all equipped SC-System modules, Standard length 250 mm (9.84 inch), simple to customize to application space, Eliminates daisy-chainspa
Bus carrier with bus PCB for 35 mm DIN mounting rail, height 15 mm, Provides DC supply voltage and the bus connection to all equipped SC-System modules, Standard length 250 mm (9.84 inch), simple to customize to application space, Eliminates daisy-chainspa
Cover for DIN mounting rail, Suitable for Power Bus, Standard length 250 mm (9.84 inch), simple to customize to application space, Packaging unit: 5 piecespa
Fixing of the bus carrier with bus PCB in the DIN mounting rail, Termination of DIN mounting rail, Suitable for Power Bus, Packaging unit: 5 pieces left, 5 pieces rightpa