Serviceline Industrial Sensors
Sales phone: 0161 622 6308
Tech phone: 0161 622 6311
Fax: 0161 624 6537
Serviceline Explosion Protection
Sales phone: 0161 622 6309
Tech phone: 0161 622 6313
Fax: 0161 624 6537

Measuring principle

The system is based on the reflection of an electromagnetic pulse that is directed on a sensor rod/ cable and reflected by filling material. The electronics integrated into the sensor determines the filling state from the echo time of the pulse and shows this in the display.

The electromagnetic pulse is sent out, reflected on the filling material and received again. The echo time of the pulse is proportional to the distance from the surface of the medium. The measurement procedure and the accuracy of the measurement are independent of pressure, temperature, vapor, dust, foam, viscosity, conductivity and pH value.


Operation mode

This continuous level measurement for liquids and bulk solids is based on the propagation time measurement of microwave pulses according to the principle of time domain reflectometry (TDR), which are guided along a rod or a rope.

A high-frequency pulse is guided along a single conductor, the sensor rod, and reflected by the medium surface. The interface electronics determines the level of the bulk material from the propagation time of the pulse. To a great extent the measuring principle is independent of process influences such as pressure, temperature or moving surfaces.


Functional Safety Hub from Pepperl+Fuchs

Several hundred products with a SIL/PL assessment, free tools, and brochures in one place: the "Functional Safety Hub" is your starting point when you have to implement safety functions.