Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
Product Description |
---|
Wireless ultrasonic sensor with LoRaWAN interface, especially for fill level measurement in tanks and silos, sensing range 250 ... 4000 mm, resolution 1 mm |
Main sensor | ||
---|---|---|
Detection type | ultrasonic | |
Sensing range | 250 ... 4000 mm | |
Dead band | 0 ... 250 mm | |
Resolution | 16 mm | |
Accuracy | ± 3 % of full-scale value over the entire temperature range | |
Measurement interval | 5 min ... 24 h | |
Integrated sensor technology | ||
GPS sensor | for geo-positioning | |
Acquisition interval | 30 min ... 24 h | |
Temperature sensor | ||
Resolution | 0.5 °C | |
Accuracy | ± 2 °C | |
Electrical specifications | ||
Power supply | high capacity lithium battery 3.6 V , 13000 mAh battery lifetime approx. 5 years under Central European environmental conditions (- 25 °C .... + 70 °C) 3 measurements/day, 1 geolocation/day with 1 wireless transmission/day with sufficient network coverage. |
|
Interface 1 | ||
Interface type | Bluetooth 5.0 LE | |
Transmitter radiated power | + 8 dBm | |
Frequency range | 2402 ... 2480 MHz | |
Interface 2 | ||
Interface type | LoRaWAN | |
Specification | LoRaWAN interface specification V1.0.3 | |
Device type | LoRaWAN class A device | |
Transmitter frequency | 868 MHz | |
Transmitter radiated power | + 8 dBm | |
Frequency range | 863 ... 870 MHz (Europe) |
|
Transmission interval | 5 min ... 24 h | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 301 489-1 V2.2.0:2017 EN 301 489-3 V2.1.1:2019 EN 301 489-17 V3.2.0:2017 EN 301 489-19 V2.1.0:2017 |
|
Radio and telecommunication terminal equipment | ||
Directive 2014/53/EU | EN 300 220-2 V3.1.1:2017 EN 300 328 V2.1.1:2016 EN 303 413 V1.1.1:2017 |
|
RoHS | ||
Directive 2011/65/EU (RoHS) | EN 50581:2012-09 | |
Conformity | ||
Mech. capacity | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 |
|
Shock resistance | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 |
|
Vibration resistance | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 |
|
Climatic conditions | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 |
|
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Degree of protection | IP66 / IP67 | |
Material | ||
Housing | PC (UL94-V0) | |
Transducer | PTFE coated housing: PBT |
|
Mass | 600 g | |
Dimensions | ||
Height | 74 mm | |
Width | 81 mm | |
Length | 182 mm | |
Factory settings | ||
Beam width | wide | |
Transmission interval | 24 h | |
Measurement interval | 24 h |
System | Classcode |
---|---|
ECLASS 13.0 | 27272803 |
ECLASS 12.0 | 27272803 |
ECLASS 11.0 | 27272803 |
ECLASS 10.0.1 | 27272803 |
ECLASS 9.0 | 27272803 |
ECLASS 8.0 | 27272803 |
ECLASS 5.1 | 27272803 |
ETIM 9.0 | EC001849 |
ETIM 8.0 | EC001849 |
ETIM 7.0 | EC001849 |
ETIM 6.0 | EC001849 |
ETIM 5.0 | EC001849 |
UNSPSC 12.1 | 41111960 |
The wireless ultrasonic sensor can be used for remote monitoring of fill level.
The fill level, but also other parameters such as geo data and sensor status data, are measured or recorded in configurable time intervals and transmitted to a counterpart in the LoRa network from where they are available for pure display or further processing.
The sensor is parameterised via a Bluetooth interface using a mobile device (smartphone or tablet) and the WILSEN app belonging to the sensor.
Literature | Language | File Type | File Size |
---|---|---|---|
Application Report - Demand-Driven Emtying of Glass-Recycling Containers | ENG | 580 KB |
Product information | Language | File Type | File Size |
---|---|---|---|
Brief Instructions - Battery Lifetime Calculator for WILSEN Devices | ENG | 148 KB | |
Integration into a LoRa Network for WS-UCC*-F406-B15-B41-01-02 | ENG | 1833 KB | |
Payload Description für WS-UCC*-F406-B15-B41-*-02 | ENG | 182 KB | |
Brief Instructions | |||
Instruction leaflet / Beipackzettel | ALL | 582 KB | |
Safety and Security Documentation | |||
Safety data sheet battery | ENG | 62 KB | |
Manuals | |||
Manual WILSEN.sonic.level WS-UCC*-F406-B15-B41* | ENG | 2754 KB |
CAD | Language | File Type | File Size |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 11207 KB |
CAD Portal / CAD Portal | ALL | LINK | --- |
Declaration of Conformity | Certificate No. | Language | File Type | File Size |
---|---|---|---|---|
EU Declaration of Conformity (P+F) / EU-Konformitätserklärung (P+F) | DOC-4915B | ALL | 47 KB |
RSS Info Service for WILSEN.sonic.level Updates
Stay informed at any time when a new firmware update for the WILSEN.sonic.level sensors is released: With our RSS feed, you will receive an email notification in your inbox immediately after the release of an update!