1-channel signal conditioner, 24 V DC supply (Power Rail), Input for 2- or 3-wire sensors, NAMUR sensors or dry contacts, Input frequency 1 mHz ... 10 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Line fault detection (LFD), Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 40 mm, Number of channels: 1-channel, Trip relay, Start-up override, Frequency conversion, Rotation speed monitoring, Pulse dividerpa
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for NAMUR sensors or dry contacts, Input frequency 1 mHz ... 5 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Line fault detection (LFD), Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 40 mm, Number of channels: 1-channel, Trip relay, Start-up override, Frequency conversion, Rotation speed monitoring, Pulse divider, Safety Integrity Level (SIL): SIL 2pa
Logic Control Units, Universal Frequency Converters
104654
Aankoop niet mogelijk: 1-channel, Input frequency 1 mHz ... 12 kHz, Analog output 0/4 mA ... 20 mA, Measuring range parameterisable, 2 relay outputs, 1 electronic output, isolated, Each output can be assigned individual parameters, such as a trip value (high/low alarm), serially switched output, pulse divider or error message output, Start-up override, Restart inhibit, Lead breakage (LB) and short-circuit (SC) monitoring, Debounce filter, Parameterization via PC or control panelpa
Logic Control Units, Universal Frequency Converters
104655
Aankoop niet mogelijk: 1-channel, Input frequency 1 mHz ... 12 kHz, Analog output 0/4 mA ... 20 mA, Measuring range parameterisable, 2 relay outputs, 1 electronic output, isolated, Each output can be assigned individual parameters, such as a trip value (high/low alarm), serially switched output, pulse divider or error message output, Start-up override, Restart inhibit, Lead breakage (LB) and short-circuit (SC) monitoring, Debounce filter, Parameterization via PC or control panelpa
Aankoop niet mogelijk: 1-channel signal conditioner, 24 V DC supply (Power Rail), Input for 2- or 3-wire sensors, NAMUR sensors or dry contacts, Input frequency 1 mHz ... 12 kHz, Current output 0/4 mA ... 20 mA, Relay and transistor output, Start-up override, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Housing width: 40 mm, Number of channels: 1-channel, Trip relay, Display, Rated voltage: 20 ... 30 V DC, Dimensions: 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C2pa
Aankoop niet mogelijk: 1-channel, Control circuit EEx ia IIC, Input frequency 1 mHz ... 5 kHz, Analog output 0/4 mA ... 20 mA, Measuring range parameterisable, 2 relay outputs, 1 electronic output, isolated, Each output can be assigned individual parameters, such as a trip value (high/low alarm), serially switched output, pulse divider or error message output, Start-up override, Restart inhibit, Lead breakage (LB) and short-circuit (SC) monitoring, Debounce filterpa
Aankoop niet mogelijk: 1-channel, Control circuit EEx ia IIC, Input frequency 1 mHz ... 5 kHz, Analog output 0/4 mA ... 20 mA, Measuring range parameterisable, 2 relay outputs, 1 electronic output, isolated, Each output can be assigned individual parameters, such as a trip value (high/low alarm), serially switched output, pulse divider or error message output, Start-up override, Restart inhibit, Lead breakage (LB) and short-circuit (SC) monitoring, Debounce filterpa
Aankoop niet mogelijk: 1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz ... 5 kHz, Current output 0/4 mA ... 20 mA, Relay and transistor output, Start-up override, Configurable by PACTware or keypad, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Housing width: 40 mm, Number of channels: 1-channel, Trip relay, Rated voltage: 20 ... 30 V DCpa
1-6/6Items per pagina:
Niet gevonden ?
Hint: plaats een * voor uw zoekwoord, verander uw zoekterm, controleer uw zoekterm op spellingsfouten, of neem contact met ons op.