1-10/22 Items per pagina: 5 10 25 50
Extended temperature range, Valve position detection, Solenoid valve output, Switching function: 2 x normally open (NO), Output type: PNP, Installation: for non-flush mounting, Output polarity: DC, Output type: 4-wire, Construction type: Dual sensor, Series: Dual sensor, Type of voltage: DC, Connection (system side): screw terminal , M20 x 1.5 cable gland, Housing material: rugged, translucent polycarbonate (PC) optimised for outdoor use, Degree of protection: IP66 / IP68 / IP69fa
Extended temperature range, Valve position detection, Solenoid valve output, Switching function: 2 x normally open (NO), Output type: Two-wire with minimum off-state current, Installation: for non-flush mounting, Output polarity: DC, Output type: 2x 2-wire, Construction type: Dual sensor, Series: Dual sensor, Type of voltage: DC, Connection (system side): screw terminal , M20 x 1.5 cable gland, Housing material: rugged, translucent polycarbonate (PC) optimised for outdoor usefa
Extended temperature range, Valve position detection, Solenoid valve output, Switching function: 2 x normally open (NO), Output type: PNP, Installation: for non-flush mounting, Output polarity: DC, Output type: 4-wire, Construction type: Dual sensor, Series: Dual sensor, Type of voltage: DC, Equipment protection level Dc: IECEx TUR 20.0068X, Equipment protection level Dc: TÜV 20 ATEX 8598 X, Ambient temperature: -40 ... 75 °C (-40 ... 167 °F) , restriction for use in hazardous area, see instruction manualfa
Extended temperature range, Valve position detection, Solenoid valve output, Switching function: 2 x normally open (NO), Output type: Two-wire with minimum off-state current, Installation: for non-flush mounting, Output polarity: DC, Output type: 2x 2-wire, Construction type: Dual sensor, Series: Dual sensor, Type of voltage: DC, Equipment protection level Dc: IECEx TUR 20.0068X, Equipment protection level Dc: TÜV 20 ATEX 8598 Xfa
Extended temperature range, Valve position detection, Solenoid valve output, Suitable for 2:1 technology, Switching function: 2 x normally closed (NC), Output type: NAMUR, Installation: flush mountable, Output type: 2-wire, Construction type: Dual sensor, Series: Dual sensor, Suitable for 2:1 technology, Safety Integrity Level (SIL): SIL 2, Type of voltage: DC, Equipment protection level Ga: IECEx TUR 17.0055X, Equipment protection level Gb: IECEx TUR 17.0055Xfa
Extended temperature range, Valve position detection, Solenoid valve output, Suitable for 2:1 technology, Switching function: 2 x normally closed (NC), Output type: NAMUR, Installation: flush mountable, Output type: 2-wire, Construction type: Dual sensor, Series: Dual sensor, Suitable for 2:1 technology, Safety Integrity Level (SIL): SIL 2, Type of voltage: DC, Equipment protection level Ga: IECEx TUR 17.0055X, Equipment protection level Gb: IECEx TUR 17.0055Xfa
Extended temperature range, Valve position detection, Solenoid valve output, Switching function: 2 x normally open (NO), Output type: PNP, Installation: for non-flush mounting, Output polarity: DC, Output type: 4-wire, Construction type: Dual sensor, Series: Dual sensor, Type of voltage: DC, Connection (system side): screw terminal , M20 x 1.5 cable gland, Housing material: rugged, translucent polycarbonate (PC) optimised for outdoor use, Degree of protection: IP66 / IP67 / IP69fa
Extended temperature range, Valve position detection, Solenoid valve output, Switching function: 2 x normally open (NO), Output type: Two-wire with minimum off-state current, Installation: for non-flush mounting, Output polarity: DC, Output type: 2x 2-wire, Construction type: Dual sensor, Series: Dual sensor, Type of voltage: DC, Connection (system side): screw terminal , M20 x 1.5 cable gland, Housing material: rugged, translucent polycarbonate (PC) optimised for outdoor usefa
Extended temperature range, Valve position detection, Solenoid valve output, Switching function: 2 x normally open (NO), Output type: PNP, Installation: for non-flush mounting, Output polarity: DC, Output type: 4-wire, Construction type: Dual sensor, Series: Dual sensor, Type of voltage: DC, Connection (system side): screw terminal , M20 x 1.5 cable gland, Housing material: rugged, translucent polycarbonate (PC) optimised for outdoor use, Degree of protection: IP66 / IP68 / IP69fa
Extended temperature range, Valve position detection, Solenoid valve output, Switching function: 2 x normally open (NO), Output type: PNP, Installation: for non-flush mounting, Output polarity: DC, Output type: 4-wire, Construction type: Dual sensor, Series: Dual sensor, Type of voltage: DC, Connection (system side): screw terminal , 1/2" NPT cable gland, Housing material: rugged, translucent polycarbonate (PC) optimised for outdoor use, Degree of protection: IP66 / IP68 / IP69fa
1-10/22 Items per pagina: 5 10 25 50