Aankoop niet mogelijk: Sensing range up to 15 m , Resolution 30 mm (hand protection), Protective field height up to 1800 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Master/Slave detection, Plug and Play, Start/Restart disable , Degree of protection IP67, Integrated function display, Operating mode: can be selected with or without start/restart disable, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Safety output: 2 separated fail safe semiconductor outputsfa
Aankoop niet mogelijk: Sensing range up to 15 m , Resolution 30 mm (hand protection), Protection field height up to 1650 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Master/Slave detection, Plug and Play, Start/Restart disable , Degree of protection IP67, Integrated function display, Operating mode: in the master, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Safety output: in the masterfa
Aankoop niet mogelijk: Sensing range up to 15 m , Resolution 30 mm (hand protection), Self-monitoring (type 4 according to IEC/EN 61496-1), Master/Slave detection, Plug and Play, Degree of protection IP67, Integrated function display, Operating reserve indication, Connection via appliance socket M12 x b1, Operating mode: can be selected with or without start/restart disable, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Safety output: 2 separated fail safe semiconductor outputsfa
Aankoop niet mogelijk: ATEX-approval for zone 2 and zone 22, Sensing range up to 15 m , Resolution 30 mm (hand protection), Self-monitoring (type 4 according to IEC/EN 61496-1), Safety outputs OSSD, external status displays OSSD, Start/Restart disable , Integrated function display, Operating reserve indication, Operating mode: can be selected with or without start/restart disable, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Safety output: 2 separated fail safe semiconductor outputsfa
Aankoop niet mogelijk: Sensing range up to 15 m , Resolution 30 mm (hand protection), Self-monitoring (type 4 according to IEC/EN 61496-1), Master/Slave detection, Plug and Play, Start/Restart disable , Degree of protection IP67, Integrated function display, Operating reserve indication, Operating mode: can be selected with or without start/restart disable, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Safety output: 2 separated fail safe semiconductor outputsfa
Aankoop niet mogelijk: Sensing range up to 15 m , Resolution 30 mm (hand protection), Protective field height up to 1800 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Master/Slave detection, Plug and Play, Start/Restart disable , Degree of protection IP67, Integrated function display, Operating mode: can be selected with or without start/restart disable, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Safety output: 2 relay outputs, force-guided NO-contactfa
Aankoop niet mogelijk: Sensing range up to 15 m , Resolution 30 mm (hand protection), Protective field height up to 1800 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Master/Slave detection, Plug and Play, Start/Restart disable , Degree of protection IP67, Integrated function display, Operating mode: can be selected with or without start/restart disable, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Safety output: 2 separated fail safe semiconductor outputsfa
Aankoop niet mogelijk: Sensing range up to 15 m , Resolution 30 mm (hand protection), Protection field height up to 1650 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Master/Slave detection, Plug and Play, Start/Restart disable , Degree of protection IP67, Integrated function display, Operating mode: in the master, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Safety output: in the masterfa
Aankoop niet mogelijk: Sensing range up to 15 m , Resolution 30 mm (hand protection), Self-monitoring (type 4 according to IEC/EN 61496-1), Master/Slave detection, Plug and Play, Degree of protection IP67, Integrated function display, Operating reserve indication, Protection field height up to 1200 mm, Operating mode: can be selected with or without start/restart disable, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Safety output: 2 separated fail safe semiconductor outputsfa
Aankoop niet mogelijk: Sensing range up to 15 m , Resolution 30 mm (hand protection), Self-monitoring (type 4 according to IEC/EN 61496-1), Master/Slave detection, Plug and Play, Start/Restart disable , Degree of protection IP67, Integrated function display, Operating reserve indication, Operating mode: can be selected with or without start/restart disable, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Safety output: 2 separated fail safe semiconductor outputsfa
1-10/70Items per pagina:
Niet gevonden ?
Hint: plaats een * voor uw zoekwoord, verander uw zoekterm, controleer uw zoekterm op spellingsfouten, of neem contact met ons op.