Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
De complete datasheet als PDF downloaden:
Productbeschrijving |
---|
Vibration sensor with IO-Link and programmable switching output or analog current output |
General specifications | ||
---|---|---|
Type | Vibration sensor | |
Measuring technology | MEMS capacitive | |
Series | Performance Plus Line | |
Measured variable | Vibration velocity Vibration acceleration Bearing status parameter Crest factor Temperature |
|
Measuring range | ||
Vibration velocity | 0 ... 128 mm/s | |
Vibration acceleration | 0 ... 34 g rms | |
Vibration acceleration | 0 ... 48 g peak value per 1 s | |
Vibration acceleration | -48 ... 48 g by means of BLOB transfer | |
Bearing status parameter | 1 ... 4 see section characteristic curve |
|
Crest factor | 0 ... 100 | |
Temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Measurement accuracy | Vibration velocity: ± 0.1 mm/s (calibration point: 90% of the measuring range; 159.2 Hz) Complies with the tolerance requirements of DIN ISO 2954 for measuring range greater than 8 mm/s Vibration acceleration: ± 0.01 g (calibration point: 90% of the measuring range; 159.2 Hz) Complies with the tolerance requirements of DIN ISO 2954 |
|
Cross-sensitivity | < 5 % of the partial lateral acceleration, which acts exactly 90° to the measuring axis | |
Resolution | Vibration velocity: 0.01 mm/s Vibration acceleration: 0.01 g Bearing status parameter: 0.01 |
|
Frequency range | Vibration acceleration a-raw: 1 ... 12 kHz , by means of BLOB transfer Vibration velocity rms: 10 ... 1000 Hz , acc. to DIN ISO 10816/20816 , programmable Vibration acceleration rms: 1 ... 1000 Hz , acc. to DIN ISO 10816/20816 , programmable Vibration acceleration a-peak: 10 ... 10 kHz Crest factor: 10 ... 10 kHz Bearing status parameter: 10 ... 10 kHz , acc. to DIN ISO 13373-3 |
|
Averaging time | for v-rms: 2 s for a-rms: 2 s |
|
Sampling rate | Vibration acceleration a-raw: 64 kHz , programmable Vibration velocity rms: 8 Hz Vibration acceleration rms: 8 kHz Vibration acceleration a-peak: 32 Hz Crest factor: 32 Hz Bearing status parameter: 32 kHz |
|
Functional safety related parameters | ||
MTTFd | 329 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Fusing | external fuse is required: 1 A , fast acting , 30 V DC | |
Operating voltage | 18 ... 30 V DC | |
Current consumption | max. 320 mA | |
Power consumption | max. 10 W | |
Time delay before availability | ≤ 3.6 s | |
Surge protection | up to 2 kV | |
Interface | ||
Interface type | IO-Link (via C/Q = Pin 4) | |
IO-Link revision | 1.1 | |
Device profile | Identification and Diagnosis - I&D , BLOB transfer | |
Process data | Input 24 Byte measurement channels: -rms value velocity - peak value acceleration - rms value acceleration - temperature - crest factor - bearing status parameter per measurement channel: - measurement value 2 Byte - scaling 8 Bit - switching signals 2 Bit status data |
|
Vendor ID | 1 (0x0001) | |
Device ID | 5308673 (0x510101) | |
Transfer rate | COM3 (230.4 kbits/s) | |
Min. cycle time | 3.8 ms | |
SIO mode support | yes | |
Compatible master port type | Class A Class B (use 3-pole adapter or 3-wire cable) |
|
BLOB size | 1.28 MByte , programmable | |
BLOB segments | 200 Byte per request and BLOB segment respectively | |
Output 1 | ||
Output type | C/Q - Pin 4 in SIO mode (switching signal of the measured variable is programmable) | |
Switching function | Normally open/closed (NO/NC) | |
Operating current | ≤ 100 mA | |
Short-circuit protection | yes | |
Output 2 | ||
Output type | I/Q - pin 2 (parameterizable as analog current output or switching signal) - I: analog output for the measured variable, current 4 ... 20 mA - Q: switching signal of the measured variable is parameterizable, PNP normally open |
|
Switching function | Normally open/closed (NO/NC) | |
Operating current | ≤ 120 mA for switching signal | |
Voltage drop | < 2 V | |
Output current | 4 ... 20 mA at analog output | |
Load resistor | ≤ 500 Ω at analog output | |
Short-circuit protection | yes | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP66, IP67 | |
Shock resistance | DIN EN 60068-2-27, 60 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 16.5 g, 10 ... 12000 Hz | |
Vibration evaluation | DIN ISO 10816/20816 , DIN ISO 13373-3 | |
Approvals and certificates | ||
UL approval | ||
Ordinary Location | E468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only. adapters providing field wiring on request |
|
Maximum permissible ambient temperature | max. 80 °C (max. 176 °F) | |
Ambient conditions | ||
Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | plug | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Degree of protection | IP66 / IP67 only in connected state | |
Connector | ||
Threading | M12 | |
Number of pins | 4 | |
Mass | approx. 100 g | |
Dimensions | ||
Length | 72.5 mm | |
Diameter | 23.8 mm |
System | Classcode |
---|---|
ECLASS 13.0 | 27271103 |
ECLASS 12.0 | 27201406 |
ECLASS 11.0 | 27201406 |
ECLASS 10.0.1 | 27201406 |
ECLASS 9.0 | 27201406 |
ECLASS 8.0 | 27201406 |
ECLASS 5.1 | 27201406 |
ETIM 9.0 | EC004309 |
ETIM 8.0 | EC004309 |
ETIM 7.0 | EC002959 |
ETIM 6.0 | EC002959 |
ETIM 5.0 | EC001758 |
UNSPSC 12.1 | 41114624 |
Literature | Taal | Bestandstype | Bestandsgrootte |
---|---|---|---|
Product Overview - Vibration Sensors | ENG | 1351 KB | |
Application Report - Servicing Mobile Concrete Mixers According to Actual Needs | ENG | 169 KB |
Product information | Taal | Bestandstype | Bestandsgrootte |
---|---|---|---|
Installation and user instructions for offline parameterization of IO-Link sensors | ENG | 1788 KB | |
Brief Instructions | |||
Instruction leaflet / Beipackzettel | ALL | 252 KB | |
Safety and Security Documentation | |||
Handleiding | HOL | 149 KB | |
Manuals | |||
Manual VIM3*-IO-* Vibration Sensors | ENG | 2011 KB | |
Parameter Information | |||
IO-Link Parameter Datasheet VIM32PP-E7DC8-0RE-IO-1V1401 | ENG | 843 KB |
CAD | Taal | Bestandstype | Bestandsgrootte |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 2046 KB |
CAD 3-D / CAD 3-D | ALL | STP | 2534 KB |
Certificates | Certificaatnummer | Taal | Bestandstype | Bestandsgrootte |
---|---|---|---|---|
IO-Link Manufacturer Declaration | CERT-7546A | ALL | 265 KB | |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitätserklärung (P+F) | DOC-6865 | ALL | 325 KB | |
EU Declaration of Conformity (P+F) / EU-Konformitätserklärung (P+F) | DOC-7705 | ALL | 236 KB | |
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F) | DOC-6866 | ALL | 249 KB | |
UK Declaration of Conformity (P+F) / UK-Konformitätserklärung (P+F) | DOC-7706 | ALL | 201 KB |
Device Description Files/Drivers | Vrijgave-informatie | Bestandstype | Bestandsgrootte |
---|---|---|---|
IODD for VIM32PP-*D*-0*-*01 / IODD für VIM32PP-*D*-0*-*01 | V2.00.000 / 2024-09-09 | ZIP | 237 KB |
Software Tools | |||
IO-Link Offline Parameterization Tool / IO-Link Offline-Parametriertool | V1.00.006 / 2022-07-10 | ZIP | 96138 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|