General specifications |
Detection type | magnetic sampling |
Device type | Heavy duty absolute rotary encoder as Pure Line |
Measured variable | position Temperature |
Linearity error | ≤ ± 0.1 ° |
UL File Number | E223176 "For use in NFPA 79 Applications only" , if UL marking is marked on the product. |
Functional safety related parameters |
MTTFd | 480 a at 40 °C |
Mission Time (TM) | 20 a |
L10 | 10 E+8 revolutions at 20/40 N axial/radial shaft load |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means |
LED STATUS | LED green flashing with short break (1 Hz) - IO-Link mode |
Electrical specifications |
Operating voltage | 18 ... 30 V DC |
No-load supply current | max. 50 mA |
Power consumption | approx. 1.5 W |
Time delay before availability | < 1 s |
Interface |
Interface type | IO-Link |
IO-Link revision | 1.1 |
Device profile | Identification and Diagnosis - I&D |
Resolution | |
| Single turn | up to 16 Bit programmable |
| Multiturn | up to 15 Bit programmable |
| Overall resolution | up to 31 Bit programmable |
Process data | Input 12 Byte - measurement value 4 Byte - resolution 16 Bit - auxiliary mesurement value 4 Byte - switching signals 2 Bit - diagnosis signals 2 Bit - status data |
Vendor ID | 1 (0x0001) |
Device ID | 5246977 (0x 501001), 5246978 (0x 501002) |
Transfer rate | COM3 (230.4 kbits/s) |
Min. cycle time | 1.5 ms |
SIO mode support | no |
Compatible master port type | Class A Class B (use 3-pole adapter or 3-wire cable) |
Connection |
Connector | M12 connector, 5 pin , A-coded |
Standard conformity |
Degree of protection | DIN EN 60529 , IP66 / IP68 / IP69K |
Communication interface | IEC 61131-9 / IO-Link V1.1.2 |
Climatic testing | DIN EN 60068-2-3, no moisture condensation |
Emitted interference | EN 61000-6-4:2007 |
Noise immunity | EN 61000-6-2:2005 |
Shock resistance | DIN EN 60068-2-27, 200 g, 11 ms |
Vibration resistance | DIN EN 60068-2-6, 30 g, 10 ... 1000 Hz |
Approvals and certificates |
UL approval | cULus Listed, General Purpose, Class 2 Power Source , if UL marking is marked on the product. |
Ambient conditions |
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Relative humidity | 98 % , no moisture condensation |
Mechanical specifications |
Material | |
| Housing | Stainless steel 1.4404 / AISI 316L |
| Flange | Stainless steel 1.4404 / AISI 316L |
| Shaft | Stainless steel 1.4412 / AISI 440B |
Mass | approx. 350 g |
Rotational speed | max. 6000 min -1 |
Moment of inertia | < 30 gcm2 |
Starting torque | < 5 Ncm |
Shaft load | |
| Axial | 270 N |
| Radial | 270 N |