Teknisk support Industrielle sensorer
Kontakt kundeservice
Kundeservice, eksplosjonsbeskyttelse
Kontakt kundeservice

IO-Link Masters with OPC UA Interface—Seamless Information Exchange from Field to Cloud

IO-Link masters with OPC UA interface
IO-Link masters with OPC UA interface

In addition to the ICE1* masters for PLC-based applications, two other modules are available for use in cloud-based and hybrid systems: the ICE2 (EtherNet/IP) and ICE3 (PROFINET) IO-Link master series. These support the industry’s leading protocols, including EtherNet/IP, PROFINET, and MODBUS TCP, and offer an OPC UA interface in addition to the real-time fieldbus protocol.

The open architecture of OPC UA (Open Platform Communication Unified Architecture) opens up cross-vendor, platform-independent, and interoperable collaboration of machines in production and makes communication between machines and computer- or cloud-based systems possible—both in closed networks and via internet.

Both IO-Link masters come with a completely web-based configuration concept for setting all module parameters and all connected IO-Link devices (web IODD operation). Thus, additional software or a higher-level programmable logic controller (PLC) are not required. When replacing or expanding modules, all module settings can be saved as a separate file and transferred to a new device using the module cloning function. OPC UA ensures a constant exchange of information across all levels so that processes in plants can be designed even more efficiently.


IO-Link Masters—Versatile and Future-Proof

Up to eight IO-Link devices can be connected to the IO-Link master.
Up to eight IO-Link devices can be connected to the IO-Link master.

If sensors are to manage the tasks of the future, they need to do more than simply deliver process data to the machine control. Sensors must be able to communicate with all different kinds of receivers and send and receive data to and from higher-level information systems. IO-Link masters facilitate reliable, efficient communication between management and sensor/actuator levels as they assume a gateway function between Ethernet and IO‑Link. Up to eight IO‑Link devices may be directly connected—four channels are available for sensors, four channels for actuators. The ICE1* series IO-Link master enables integrated diagnostics and parameterization from the control level right down to the sensor level. They are optimized for PLC-based applications. Commissioning times are also significantly reduced, primarily in large-series production plants. With its multiprotocol functionality, the ICE11 IO-Link master supports PROFINET, EtherNet/IP, EtherCAT, CC-Link, and MODBUS TCP.

This means that the IO-Link master can be ideally incorporated into the requirements profile of innovative machine and plant manufacturers—forming a crucial component of Sensorik4.0®.


IIoT Starter Kit—Connecting Factory Floor Sensors to the Cloud and Starting the Digital Transformation


With the IIoT starter kit and the user-friendly IO-Link masters from Pepperl+Fuchs simple visualization and analysis of sensor data become a reality. Discover the advantages of IO-Link and experience the seamless integration of IO-Link sensor data into your Industry 4.0 application.

The kit includes among others:

  • An IO-Link master, (3) IO-Link sensors, an Ethernet switch, a power supply, RFID tags and all the necessary cabling to get started
  • A quick start guide for connecting the IO-Link master and IO-Link devices
  • Connections for various platforms such as AWS, PTC, AVEVA

Connect your software dashboard via OPC UA or MQTT for easy interpretation of real-time data and start the digital transformation of your plants now with the new IIoT starter kit from Pepperl+Fuchs.


IIoT Starter Kit

Connect your factory floor sensors to the cloud and start your digital transformation with the new IIoT starter kits.

Free Download: White Paper on TCP-Based Communication Protocols (PDF)

Dette gratis PDF-dokumentet sammenligner de forskjellige TCP-baserte kommunikasjonsprotokollene (AMQP, OPC UA, MQTT, REST API) som har funnet veien opp og regnes som muliggjørerne for IIoT og Industry 4.0. Last ned gratis nå!

IO-Link Master with OPC UA Interface

The ICE 2 and ICE3 IO-Link master series come with an OPC UA interface and a real-time fieldbus protocol, making them an ideal solution for cloud-based applications. Read more about possible scenarios in our blog.

undefined

We value your privacy!

We and our partners are using technologies like cookies and process personal data like the IP-address or browser information in order to personalize the advertising that you see. This helps us to show you more relevant ads and improves your internet experience. We also use it in order to measure results or align our website content. Because we value your privacy, we are herewith asking for your permission to use these technologies. You can always change/withdraw your consent later by clicking on the settings button on the left lower corner of the page.

Deny all cookies

We value your privacy!

Please select the group of cookies and scripts, that you consent to.

Functional
These cookies are necessary so that you can navigate through the pages and use essential functions (e.g. login).
Analytics
We use these cookies and scripts to measure the visits and clicks on our website in order to constantly improve it.
Marketing
These cookies and similar technologies are used to provide you with personalized and therefore relevant advertising content.