Wsparcie Czujników Przemysłowych
Wsparcie Ochrony przed wybuchem
Niedostępne do zakupu
Niedostępne do zakupu

Read/write station IUT-F191-R4-V1-FR2-02

IUT-F191-R4-V1-FR2-02
  • Flexible UHF read/write station with short detection range
  • Compact and robust housing for harsh industrial environments
  • Multi-tag reading of up to 20 tags ensures increased productivity
  • Circular antenna polarization ensures reliable transponder detection and improves process flow
  • Connection via integrated RS-485 interface

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Pobierz pełną kartę katalogową w formie pliku PDF:


Dane techniczne  IUT-F191-R4-V1-FR2-02

Opis produktu
UHF read/write station, USA and Canada
General specifications
Operating frequency902 … 928 MHz: USA, Canada
Transmission licenses for other countries on request
Emitted power3 … 150 mW EIRP adjustable
Indicators/operating means
LED greenReady for operation
LED yellowRead/write operation successful
LED blueTransmission mode
Electrical specifications
Rated operating voltage10 ... 30 V DC
Current consumption≤ 190 mA
Power consumption≤ 1.9 W
Surge protectioncategory 2
Interface
Physical RS-485 point-to-point connection
ProtocolASCII
Transfer rate38400 Bit/s
Standard conformity
Electromagnetic compatibilityEN 301489-1
EN 301489-3
Degree of protectionEN 60529
RFIDISO/IEC 18000-63
Approvals and certificates
FCC approvalThis device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
Caution:
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
IC approvalThis device complies with Industry Canada licence-exempt RSS standard(s) and with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Ambient conditions
ClassificationEnvironmental condition A (controlled environment)
Ambient temperature-25 ... 70 °C (-13 ... 158 °F) (Operation with nontransmission periods)
-25 ... 55 °C (-13 ... 131 °F) (Continuous transmission mode)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Pollution degree2
Mechanical specifications
Degree of protectionIP67
Connectionconnector M12 x 1
Material
HousingPA 6.6
Mass700 g
Dimensions
Height47 mm
Width165 mm
Length165 mm

Classifications

SystemClasscode
ECLASS 13.027280401
ECLASS 12.027280401
ECLASS 11.027280401
ECLASS 10.0.127280401
ECLASS 9.027280401
ECLASS 8.027280401
ECLASS 5.127280401
ETIM 9.0EC002998
ETIM 8.0EC002998
ETIM 7.0EC002998
ETIM 6.0EC002998
ETIM 5.0EC002998
UNSPSC 12.143211710

Details: IUT-F191-R4-V1-FR2-02

Function

The read/write station operates in the UHF frequency range and is optimized for use in industrial applications involving shorter distances. The device reads and writes passive tags acc. to EPC Generation 2 ( ISO/IEC 18000-63). The read/write station is compliant with the relevant transmission regulations.

The read/write station can be used in the USA and Canada.

Wide range of options supported for filtering data. The read/write station has an RS-485 interface and is connected via an M12 connector. The user can monitor the status of the read/write station using the integrated LEDs.

The read/write station has a typical detection range of around 1 meter; this range is determined by the tag used and can be adjusted by configuring the transmission power. Other influencing factors include the setup and installation of the specific application and the surrounding materials, particularly metal. The read and write distances for the relevant tag, which are detailed separately, have been established in a test laboratory under ideal conditions. For the actual read and write distances under real conditions, the combination of read/write station and tag must be tested in the desired application.

Product Documentation: IUT-F191-R4-V1-FR2-02

Language Selection:
We are sorry, there are no documents for your language selection. Please select another language.

Design / Simulation: IUT-F191-R4-V1-FR2-02

Language Selection:
CADJęzykTyp plikuRozmiar pliku
CAD 3-D / CAD 3-DALLSTP1114 KB

Approvals: IUT-F191-R4-V1-FR2-02

Language Selection:
Declaration of ConformityNr. certyfikatuJęzykTyp plikuRozmiar pliku
Simplified EU Declaration of Conformity / Vereinfachte EU-Konformitätserklärung   ALLPDF61 KB

Produkty powiązane: IUT-F191-R4-V1-FR2-02

Accessories

Cordset M12 socket straight to M12 plug angled A-coded, 4-pin, PUR cable grey, shieldedfa

Cordset M12 socket straight to M12 plug angled A-coded, 4-pin, PUR cable grey, shieldedfa

Cordset M12 socket straight to M12 plug angled A-coded, 4-pin, PUR cable grey, shieldedfa
RFID Transponderfa
Urządzenie do odczytu/zapisu RFID IUT-F190-B40 z interfejsem przemysłowym Ethernet i REST API

Zapoznaj się z nową głowicą IUT-F190-B40, zaprojektowaną dla średnich zakresów detekcji, którą można szybko i łatwo zintegrować z systemami zarządzania i informatycznymi…

Odwiedź RFID Hub

Odwiedź „RFID Hub” — specjalną stronę internetową, która jest bazą wiedzy o RFID. Uzyskaj odpowiedzi na często zadawane pytania i zapoznaj się z typowymi zastosowaniami RFID…