Serviceline Industrial Sensors
Serviceline Explosion Protection

Read head WCS3B-LS311DH-OM

WCS3B-LS311DH-OM
  • For outdoor use
  • Non-contact, absolute position encoder
  • Extended temperature range
  • Automatic detection of dirt accumulation
  • Freely selectable cable outlet due to rotating insert
  • SSI interface

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  WCS3B-LS311DH-OM

Product Description
Reading head, SSI interface, Gray code
General specifications
Passage speed≤ 12.5 m/s
Measuring lengthmax. 314.5 m
Free tolerances to code railhorizontal: 28 mm ( ± 14 mm )
vertical: 25.5 mm ( +11.5 mm/-14 mm )
Resolution± 0.4 mm (1,250 positions/m)
Functional safety related parameters
MTTFd51 a
Mission Time (TM)10 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
Operation indicatorLED green: power on
Data flow indicatorLED yellow: data communication active
Error indicatorLED red
flashing: read head outside of code rail
solid on: internal diagnostic test failed
DisplayDisplay module, 6-digit , adaptable to installation position
Electrical specifications
Operating voltage10 ... 30 V DC
Power consumption11 VA at 24 V DC
Interface
Interface typeSSI interface
Data output codeGray code , 25 bit
Clock frequency100 ... 1000 kHz
Pause time≥ 20 µs double request possible, if tp ≤ 10 µs
Standard conformity
Emitted interferenceDIN EN 61000-6-4

Noise immunityDIN EN 61000-6-2

Shock resistanceDIN EN 60068-2-27, half sine 30 g, 18 ms
Vibration resistanceDIN EN 60068-2-6, sine, 5 g, 10 - 2000 Hz, 10 cycles
Approvals and certificates
CSA approvalcCSAus Certified, General Purpose
Class 2 power source
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Operating temperature-40 ... 60 °C (-40 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type8-pin, M12 x 1 connector
Degree of protectionIP67 / IP69
Material
HousingPET , PC (Polycarbonate)
Mass1000 g
NoteThe reader must not be operated without the protective housing!

Classifications

SystemClasscode
ECLASS 13.027270918
ECLASS 12.027270918
ECLASS 11.027270701
ECLASS 10.0.127270701
ECLASS 9.027270701
ECLASS 8.027270701
ECLASS 5.127270701
ETIM 9.0EC001852
ETIM 8.0EC001852
ETIM 7.0EC001852
ETIM 6.0EC001852
ETIM 5.0EC001852
UNSPSC 12.141111945

Details: WCS3B-LS311DH-OM

Informative Literature: WCS3B-LS311DH-OM

Language Selection:
LiteratureLanguageFile TypeFile Size
Application Report - Position Encoding System (WCS) Tackles Positioning Tasks in Container TerminalsENGPDF226 KB
Application Report - Position Encoding System (WCS) for Absolute Positioning in Galvanic PlantsENGPDF240 KB

Product Documentation: WCS3B-LS311DH-OM

Language Selection:
Brief InstructionsLanguageFile TypeFile Size
Zusammenbau / Assembly / Assemblage / Asamblea / Montaggio / Zusammenbau / Assembly / Assemblage / Asamblea / MontaggioALLPDF1773 KB
Manuals
Manual WCS ElectricalENGPDF11790 KB
Manual WCS MechanicalENGPDF12338 KB

Design / Simulation: WCS3B-LS311DH-OM

Language Selection:
CADLanguageFile TypeFile Size
CAD 3-D / CAD 3-DALLSTP1674 KB
CAD Portal / CAD PortalALLLINK---
CAE
CAE EPLAN Data Portal / CAE EPLAN Data PortalALLLINK---
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZALLEDZ53 KB

Approvals: WCS3B-LS311DH-OM

Language Selection:
CertificatesCert No.LanguageFile TypeFile Size
Canada USA CSA Ordinary Location1007121ALLPDF198 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-0909FALLPDF87 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)DOC-6636AALLPDF84 KB

Associated Products: WCS3B-LS311DH-OM

Accessory of
WCS3 guiding trolley for the WCS3B read head with protective enclosure, outdoor use, Ensures the optimum alignment of reading head and code rail, Plastic rollersfa
Accessories
Stopping plugs For WCS32B-OP* housing, Accessory WCS3Bfa
Outdoor protective cover for WCS3B reader, Accessory WCS3Bfa
Outdoor protective housing for reader WCS3B, Accessory WCS3B, Selectable connector position: left, middle, right, SSI interface, RS-485 interface, CANopen interfacefa