Serviceline Industrial Sensors
Serviceline Explosion Protection

Magnetic field sensor 50FY41-V4A-50

50FY41-V4A-50
  • Hall Effect Sensor
  • Sensing range 2.5 mm
  • 4-wire DC

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  50FY41-V4A-50

General specifications
Switching functionNormally open (NO)
Output typePNP/NPN
Rated operating distance2.5 mm at 0 mm offset, 1.3 mm at 3.5 mm offset, 0 mm at 4.0 mm offset
Installationnon-flush
Output polarityDC
Output type4-wire
Nominal ratings
Operating voltage10 ... 12 V
Short-circuit protectionNO
Voltage drop7 V @ 10 K load, 12 V supply
Operating current0.5 mA
Current consumption30 mA
Compliance with standards and directives
Standard conformity
StandardsIEC 60947-5-2:2012
IEC 60947-5-3:2013
IEC 61236-3-1:2008
Approvals and certificates
CE conformity2014/30/EU
UL approvalcULus Listed, General Purpose
Ambient conditions
Ambient temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection typecable PVC , 15 m
Core cross section0.34 mm2
Housing material316 stainless steel
Sensing face316 stainless steel
Degree of protectionIP69K
Dimensions
Width39 mm
Depth12.7 mm
Length39 mm
NoteOnly approved for use with FYQLA1-140R-3 and KE5D2-6H/2R-S
Use only with actuator 52FY31-V4A

Classifications

SystemClasscode
ECLASS 13.027274301
ECLASS 12.027274301
ECLASS 11.027270104
ECLASS 10.0.127270104
ECLASS 9.027270104
ECLASS 8.027270104
ECLASS 5.127270104
ETIM 9.0EC002544
ETIM 8.0EC002544
ETIM 7.0EC002544
ETIM 6.0EC002544
ETIM 5.0EC002544
UNSPSC 12.139121550

Details: 50FY41-V4A-50

Product Documentation: 50FY41-V4A-50

Language Selection:
Safety and Security DocumentationLanguageFile TypeFile Size
Instruction manualENGPDF165 KB

Design / Simulation: 50FY41-V4A-50

Language Selection:
CADLanguageFile TypeFile Size
CAD 3-D / CAD 3-DALLSTP74 KB
CAD Portal / CAD PortalALLLINK---

Approvals: 50FY41-V4A-50

Language Selection:
CertificatesCert No.LanguageFile TypeFile Size
Canada USA UL Hazardous LocationE501628:1:7ALLPDF411 KB
Canada USA UL Ordinary LocationUL-CA-L87056-31-81019102-0 / UL-US-L87056-11-81019102-0ALLPDF546 KB
Worldwide UL IECEx iaIECEx ULD 20.0030XALLLINK---
Control Drawings
Control drawing UL / Control drawing UL   ALLPDF252 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-0279FALLPDF107 KB

Associated Products: 50FY41-V4A-50

Accessory of
fa
24 V AC/DC supply, 6 monitored inputs, DIN rail mountable, Dual output relay contacts, Internal relay monitoringfa
Accessories
fa