Download the complete datasheet as a PDF:
Product Description |
---|
SSI/analog signal converter |
Indicators/operating means | ||
---|---|---|
LED green | status display | |
Electrical specifications | ||
Fusing | External: T 0.5 A Reverse polarity protection |
|
Operating voltage | 18 ... 30 V DC | |
Operating current | approx. 50 mA (Unladen) | |
Supply | Encoder: 5 VDC/24 VDC Max. 250 mA |
|
Interface 1 | ||
Interface type | Serial RS-232, RS-485 | |
Transfer rate | 9600, 19200, or 38400 baud | |
Interface 2 | ||
Connection of | Clock, /Clock, Data, /Data | |
Interface type | SSI Managing or managed operations |
|
Frequency range | max. 1 MHz | |
Load current | max. 3 mA / Ri > 10 kΩ / 10 pF | |
Resolution | 10 bits … 32 bits | |
Data format | Binary code or gray code | |
Interface 3 | ||
Interface type | Start/Stop RS422 input: 1 x (Start_Stop, /Start_Stop); 1x (ext. Init_In, ext. /Init_In) RS422 output: 1 x (Init_Out, /Init_Out) |
|
Resolution | Depends on the speed of the encoder wave guide | |
Frequency | Init pulse width: 1 s … 9 µs (adjustable) Init pulse frequency: 62.5 ... 5000 Hz (adjustable) Time measured via pulse frequencies: 48 MHz |
|
Input 1 | ||
Input type | Incremental | |
Input format | RS422, TTL, HTL differential, HTL PNP, or HTL NPN | |
Connection | Lanes: A, /A, B, /B | |
Input frequency | RS422: max. 1 MHz (RS422 differential signal > 0.5 V) HTL differential: max. 500 kHz (HTL differential signal > 2 V) TTL/HTL (PNP/NPN): max. 250 kHz |
|
Load current | Max. 6 mA/Ri > 5 kΩ/10 pF | |
Input 2 | ||
Input type | 6 x Control input | |
Input format | HTL, PNP (low: 0 V … 3 V, high: 9 V … 30 V) | |
Input frequency | max. 10 kHz | |
Load current | Max. 2 mA/Ri > 15 kΩ/470 pF | |
Output 1 | ||
Number/Type | Analog output Configurable as Current or voltage output |
|
Current | 0/4 mA … 20 mA (Max. load: 270 Ω) | |
Voltage | -10 ... 10 V (Max. 2 mA) | |
Resolution | 16 bit ± 0.1 % at 0 °C … 45 °C ± 0.15 % at -20 °C … 0 °C und 45 °C … 60 °C |
|
Response time | < 1 ms | |
Output 2 | ||
Output type | 6 x Control output | |
Output format | PNP | |
Output voltage | 5 V … 30 V (Depending on voltage at COM+) | |
Output rated operating current | max. 200 mA | |
Response time | < 1 ms | |
Standard conformity | ||
Electromagnetic compatibility | EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61326-1 | |
Ambient conditions | ||
Operating temperature | -20 ... 60 °C (-4 ... 140 °F) (noncondensing) | |
Storage temperature | -25 ... 75 °C (-13 ... 167 °F) (noncondensing) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals , Max. core cross section: 1.5 mm2 / AWG 16 | |
Material | ||
Housing | plastic | |
Installation | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Mass | approx. 100 g | |
Dimensions | (W x H x D) 23 mm x 102 mm x 102 mm |
System | Classcode |
---|---|
ECLASS 13.0 | 27210904 |
ECLASS 12.0 | 27210904 |
ECLASS 11.0 | 27210904 |
ECLASS 10.0.1 | 27210904 |
ECLASS 9.0 | 27210904 |
ECLASS 8.0 | 27210904 |
ECLASS 5.1 | 27210904 |
ETIM 9.0 | EC002918 |
ETIM 8.0 | EC002918 |
ETIM 7.0 | EC002918 |
ETIM 6.0 | EC002918 |
ETIM 5.0 | EC002475 |
UNSPSC 12.1 | 39121007 |
The K23-SSI/Rx/IU-C is a small and inexpensive, but extremely powerful signal converter for industrial applications, where SSI telegrams from sensors or encoders are converted into an analog signal or a serial RS-232/RS-485 format.
The device is contained in a compact housing for rail mounting.
The device features
screw terminals
a USB connection
6 user-configurable digital control inputs
6 user-configurable digital preset outputs
Applicable encoders and sensors
Encoders and all comparable sensors with SSI interface (10 ... 32 bit binary or Gray code), either in leading mode (the device generates the clock signal itself), or in guided mode (the device switches to an existing clock signal).
Incremental input signals are processed in frequency converter mode or counter mode. In start-stop mode, transonic or magnetostrictive displacement sensors can be connected.
Manuals | Language | File Type | File Size |
---|---|---|---|
Manual K23-SSI/Rx/IU-C | ENG | 3181 KB |
CAD | Language | File Type | File Size |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 1254 KB |
Declaration of Conformity | Cert No. | Language | File Type | File Size |
---|---|---|---|---|
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-4913 | ALL | 161 KB |
Software Tools | Release Info | File Type | File Size |
---|---|---|---|
software tool to configure K23-SSI devices and TC-LCDC displays / Parametrier- und Konfigurationssoftware für K23-SSI und TC-LCDC | 08/2021 | ZIP | 85353 KB |