Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
Product Description |
---|
Ethernet IO-Link module with 4x Class A and 4x Class B IO-Link ports |
General specifications | ||
---|---|---|
UL File Number | E223772 | |
Indicators/operating means | ||
LED indication | see manual | |
Rotary switch | Setting the fieldbus protocol | |
Electrical specifications | ||
Rated operating voltage | 20 ... 30 V | |
Nominal voltage | 24 V DC (SELV/PELV) | |
Current consumption | typ. 160 mA ± 20 % at nominal voltage | |
Current loading capacity | Max. 2 x 16 A per module max. 9 A via US max. 9 A via UAUX |
|
Interface | ||
Interface type | Industrial Ethernet | |
Physical | M12, D-coded | |
Protocol | PROFINET IO , EtherNet/IP , EtherCAT® , CC-Link IE Field Basic , MODBUS TCP | |
Transfer rate | Fast Ethernet 10/100 Mbps , full duplex | |
Inputs/Outputs | ||
Number/Type | 4 x IO-Link Class A (X1 - X4) 4 x IO-Link Class B (X5 - X8) configurable as: max. 8 IO-Link and 4 digital inputs/outputs + 4 digital outputs max. 12 digital inputs and 4 digital outputs max. 16 digital outputs short-circuit protected |
|
Sensor supply | max. 4 A per port (X1 - X8) via L+ (pin 1) max. 6.5 A per port pair (X1/X2, X3/X4, X5/X6, X7/X8) max. 5 A per port pair (X1/X2, X3/X4, X5/X6, X7/X8) for UL applications |
|
Output current | max. 500 mA per port (X1 - X8) via C/Q (Ch. A/pin 4) max. 2 A per port (X1 - X8) via DO (Ch. B/pin 2) max. 5 A total current X5 ... X8 via UAUX |
|
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 55032 | |
Standard conformity | ||
Degree of protection | EN 60529:2000 | |
Fieldbus standard | Type 1 according to IEC 61131-2 | |
Shock resistance | EN 61131-2:2004 | |
Approvals and certificates | ||
UL approval | ||
Maximum permissible operating current | max. 9 A | |
Ambient conditions | ||
Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Relative humidity | max. 95 % | |
Altitude | 0 ... 2000 m | |
Shock and impact resistance | 50 g, 11 ms, all axes | |
Vibration resistance | 15 g at 5 - 500 Hz | |
Pollution degree | 3 | |
Mechanical specifications | ||
Contact elements | PA | |
Degree of protection | IP65 / IP67 / IP69K | |
Connection | Power Supply M12, L-coded Fieldbus M12, D-coded Inputs/Outputs M12, A-coded |
|
Material | ||
Contacts | CuSn, gold-plated CuNi, gold-plated |
|
Housing | Diecast zinc | |
Seal | FKM | |
Mass | 480 g | |
Tightening torque, fastening screws | 1 Nm | |
Tightening torque, cable gland | 0.5 Nm | |
Dimensions | ||
Height | 200 mm | |
Width | 59.6 mm | |
Length | 21 mm | |
Construction type | Field housing | |
Tightening torque of clamping screws | 0.5 Nm |
System | Classcode |
---|---|
ECLASS 13.0 | 27242608 |
ECLASS 12.0 | 27242608 |
ECLASS 11.0 | 27242608 |
ECLASS 10.0.1 | 27242608 |
ECLASS 9.0 | 27242608 |
ECLASS 8.0 | 27242608 |
ECLASS 5.1 | 27242608 |
ETIM 9.0 | EC001597 |
ETIM 8.0 | EC001597 |
ETIM 7.0 | EC001597 |
ETIM 6.0 | EC001597 |
ETIM 5.0 | EC001597 |
UNSPSC 12.1 | 32151705 |
The module is a multiprotocol fieldbus module with 4 x IO-Link ports Class A and 4 x IO-Link ports Class B according to IO-Link standard V1.1.3.
The G60L design in fully cast metal housing is resistant to mechanical damage and environmental influences. The G60L has protection class IP65/IP67.
The fieldbus module serves as an interface between the controller of a fieldbus system and the field level. Due to its multiprotocol capability, the fieldbus module supports the Ethernet communication protocols PROFINET, EtherNet/IP, EtherCAT, CC-Link, and MODBUS TCP.
An L-coded M12 connector plug used for supplying power enables a current rating of up to 2 x 16 A via U S and U AUX. The inputs and outputs are equipped with A-coded M12 connector plugs. Connection to the fieldbus is achieved using a D-coded M12 connector plug.
The communication protocols are configured either manually via a rotary switch or automatically. The diagnostics display status information for each channel via LEDs. An integrated web server enables access to the fieldbus module. Information regarding the status of the module is also displayed and network parameters such as the IP address and subnet mask can be configured.
Manuals | Language | File Type | File Size |
---|---|---|---|
Manual ICE11-8IOL-G60L-V1D | ENG | 11821 KB |
CAD | Language | File Type | File Size |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 8927 KB |
Certificates | Cert No. | Language | File Type | File Size |
---|---|---|---|---|
Canada, USA UL | CoC E223772 RptRef E223772-20220705 | ALL | 340 KB | |
IO-Link Manufacturer Declaration | CERT-7407 | ALL | 187 KB | |
Declaration of Conformity | ||||
EU-Declaration of conformity | TDOC-7259AENG | ENG | 196 KB | |
UK-Declaration of conformity | TDOC-7260AENG | ENG | 171 KB |
Device Description Files/Drivers | Release Info | File Type | File Size |
---|---|---|---|
EtherCAT ESI Files / EtherCAT ESI Dateien | 08/2024 | ZIP | 38 KB |
EtherNet/IP EDS Files / EtherNet/IP EDS Dateien | 06/2024 | ZIP | 24 KB |
PROFINET GSDML Files / PROFINET GSDML Dateien | 07/2024 | ZIP | 112 KB |
CC-Link CSPP Files / CC-Link CSPP Dateien | 09/2024 | ZIP | 53 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|