Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
Product Description |
---|
6100 series purge and pressurization enclosure protection mini vent |
General specifications | ||
---|---|---|
Series | 6100 Series | |
System | Ex pxb Purge | |
Hazardous environment | gas | |
Electrical specifications | ||
Connection | ||
Power | Intrinsically safe connection to the 6100 control unit | |
Signal | 2-wire intrinsically safe pressure switch | |
Connection | 2-wire | |
Pneumatic parameters | ||
Protective gas supply | Clean air or inert gas | |
Safe pressure | 0.625 mbar [0.25 in wc / 6.4 mm wc) | |
Enclosure pressure | 0 ... 50 mbar (0 ... 20.1 in wc / 0 ... 510.5 mm wc) | |
Flow rate for leakage compensation | depends on enclosure seal based on completely sealed enclosure |
|
Breaking pressure | Approx. 10 mbar (4.0 in wc) Approx. 15 mbar (6.0 in wc) Approx. 20 mbar (8.0 in wc) Approx. 30 mbar (12.1 in wc) Approx. 40 mbar (16.1 in wc) |
|
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
RoHS | ||
Directive 2011/65/EU (RoHS) | EN 50581:2012 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Storage temperature | -20 ... 80 °C (-4 ... 176 °F) | |
Relative humidity | 5 ... 95 %, noncondensing | |
Vibration resistance | EN 60068-2-6 | |
Impact resistance | EN 60068-2-27 | |
Mechanical specifications | ||
Material | 316L stainless steel (housing) | |
Installation | -gravity dependent -air outlet, screen side must be facing down |
|
Mass | 9 kg (20 lb) | |
Data for application in connection with hazardous areas | ||
Certificate | CML 19 ATEX 1425X | |
Marking | II2G Ex db eb ib [ib Gb][pxb Gb] IIC T4 Gb | |
Directive conformity | ||
Directive 2014/34/EU | EN IEC 60079-0:2018 EN 60079-1:2014 EN 60079-2:2014 EN 60079-7:2015 EN 60079-11:2012 |
|
International approvals | ||
IECEx approval | IECEx CML 19.0156X Ex db eb ib [ib Gb][pxb Gb] IIC T4 Gb |
|
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. Supplemental Standards : EN 61010-1:2010 |
System | Classcode |
---|---|
ECLASS 13.0 | 27180591 |
ECLASS 12.0 | 27180591 |
ECLASS 11.0 | 27180591 |
ECLASS 10.0.1 | 27291390 |
ECLASS 9.0 | 27291390 |
ECLASS 8.0 | 27291390 |
ECLASS 5.1 | 40050501 |
ETIM 9.0 | EC000243 |
ETIM 8.0 | EC000243 |
ETIM 7.0 | EC000243 |
ETIM 6.0 | EC000243 |
ETIM 5.0 | EC000243 |
UNSPSC 12.1 | 39121303 |
The Motor Purge Mini Vent pressure relief device exhausts excess pressure from the motor/enclosure. It features a pressure switch that monitors the differential pressure across the vent orifice during the purging cycle. The differential pressure is used to verify the flow through the vent. The pressure switch is connected to the 6100 EPCU. It is intrinsically safe through the galvanic isolation barrier within the 6100 EPCU.
Safety and Security Documentation | Language | File Type | File Size |
---|---|---|---|
Instruction manual | ENG | 172 KB | |
Manuals | |||
Manual | ENG | 5218 KB |
Certificates | Cert No. | Language | File Type | File Size |
---|---|---|---|---|
Brasil Certificate of Compliance | DNV 24.0062 X | ALL | 421 KB | |
Europe CML ATEX Certificate II 2 G | CML 19ATEX1425X | ALL | 118 KB | |
IECEx Certificate of Conformity | IECEx CML 19.0156X | ALL | LINK | --- |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitätserklärung (P+F) | DOC-B0D7C | ALL | 113 KB | |
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F) | DOC-B0F6 | ALL | 160 KB |