General specifications |
Detection type | photoelectric sampling |
Linearity error | ± 0.025 ° |
Pulse count | max. 5000 |
Functional safety related parameters |
MTTFd | 435 a |
Mission Time (TM) | 10 a |
Diagnostic Coverage (DC) | 0 % |
Electrical specifications |
Operating voltage | 4.75 ... 30 V DC |
No-load supply current | max. 50 mA |
Output |
Output type | push-pull or RS422 (universal output driver, output level depending on input voltage) |
Load current | max. per channel 40 mA , short-circuit protected, reverse polarity protected |
Output frequency | max. 400 kHz |
Rise time | 300 ns |
Phase position A to B | |
| Pulse counts < 3600 | 90 ° ± 9 ° electrical |
| Pulse counts ≥ 3600 | 90 ° ± 25 ° electrical |
Duty cycle | 1/2 ± 10 % |
Connection |
Connector | M12 connector, 8-pin M12 connector, 5 pin M23 connector, 12-pin , clockwise rotation M23 connector, 12-pin , counter clockwise rotation |
Cable | ∅6 mm, 4 x 2 x 0.14 mm2 |
Terminal compartment | Cable duct for cable diameter ∅4.0 mm ... 9.5 mm |
Standard conformity |
Degree of protection | DIN EN 60529, IP65, IP66, IP67 |
Climatic testing | DIN EN 60068-2-78 , no moisture condensation |
Emitted interference | EN IEC 61000-6-4:2019 |
Noise immunity | EN IEC 61000-6-2:2019 |
Shock resistance | DIN EN 60068-2-27, 200 g, 6 ms |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 2000 Hz |
Approvals and certificates |
UL approval | E223176 , cULus Listed, General Purpose, Class 2 Power Source, Type 1 enclosure , if UL marking is marked on the product. For use in NFPA 79 Applications only. adapters providing field wiring on request |
| Maximum permissible ambient temperature | max. 80 °C (max. 176 °F) |
Ambient conditions |
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) , fixed cable -5 ... 85 °C (23 ... 185 °F) , movable cable |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications |
Material | |
| Housing | powder coated aluminum |
| Flange | aluminum, blank |
| Shaft | Stainless steel 1.4305 / AISI 303 |
Mass | < 1100 g without cable |
Rotational speed | max. 6000 min -1 for IP65 max. 3000 min -1 for IP66/IP67 |
Starting torque | ≤ 0.1 Nm for IP65 ≤ 0.25 Nm for IP66/IP67 |
Shaft insulation | max. 2.5 kV (for dielectric strength version) |
Shaft load | |
| Axial | ≤ 100 N |
| Radial | ≤ 300 N |
Dimensions | |
| Length | 84.5 mm |
| Diameter | 93 mm |