Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
Product Description |
---|
Field junction box, stainless steel enclosure solution for field installation |
General specifications | ||
---|---|---|
Design / Mounting | Outside installation | |
Installation in hazardous area | Zone 1 / Div. 1 | |
Fieldbus connection | ||
Main cable (Trunk) | ||
Cable entry type | Cable gland | |
Connection | input (Trunk IN): terminals 1+, 2-, 3s output (Trunk OUT): terminals 4+, 5-, 6s |
|
Rated voltage | max. 35 V DC | |
Rated current | 3 A DC | |
Outputs | ||
Number of outputs | see table "Technical data depending on model" | |
Cable entry type | Cable gland | |
Connection | Spur 1: terminals 10+, 11-, 12s Spur 2: terminals 13+, 14-, 15s Spur 3: terminals 16+, 17-, 18s Spur 4: terminals 19+, 20-, 21s Spur 5: terminals 22+, 23-, 24s Spur 6: terminals 25+, 26-, 27s Spur 7: terminals 28+, 29-, 30s Spur 8: terminals 31+, 32-, 33s |
|
Rated voltage | see main cable | |
Rated current | see main cable | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2004/108/EC | EN 61326-1:2006 | |
Standard conformity | ||
Electromagnetic compatibility | NAMUR NE 21, EN 61326 | |
Degree of protection | IEC/EN 60529 | |
Fieldbus standard | IEC 61158-2 | |
Climatic conditions | DIN IEC 721 | |
Ambient conditions | ||
Ambient temperature | see table | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | screw terminal , fixed | |
Core cross section | up to 2.5 mm2 | |
Cable diameter | ||
Main cable (Trunk) | 5 ... 10 mm | |
Housing | 258 mm x 114 mm x 84 mm (without cable glands) | |
Housing material | Aluminum | |
Degree of protection | IP67 | |
Mass | 1800 g | |
Mounting | wall mounting | |
Data for application in connection with hazardous areas | ||
Main cable (Trunk) | only for connection to intrinsically safe fieldbus circuits | |
Maximum values | ||
Voltage | max. 35 V | |
Current | max. 3 A | |
Directive conformity | Standards | |
Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-11:2012 |
System | Classcode |
---|---|
ECLASS 13.0 | 27242691 |
ECLASS 12.0 | 27242691 |
ECLASS 11.0 | 27242691 |
ECLASS 10.0.1 | 27242691 |
ECLASS 9.0 | 27242691 |
ECLASS 8.0 | 27242691 |
ECLASS 5.1 | 27242691 |
ETIM 9.0 | EC001601 |
ETIM 8.0 | EC001601 |
ETIM 7.0 | EC001601 |
ETIM 6.0 | EC001601 |
ETIM 5.0 | EC001604 |
UNSPSC 12.1 | 39121008 |
The fieldbus junction box is a passive device coupler that connects instruments to intrinsically safe segments. The housing (type F2) is made of sturdy aluminum for installation in rough environments Zone 1/Division 1.
As an associated apparatus, the junction box is permitted for trunk and spur connections that are rated intrinsically safe (Ex ia, Ex ib) for instruments located in Zone 0 ... 1/Division 1.
A choice of fixed screw terminals or plug-in spring terminals is available. Hard and capacitive grounding concepts are selectable via jumper.
Literature | Language | File Type | File Size |
---|---|---|---|
Application Report - Controlling and Monitoring liquid Helium at the Deutsches Elektronen-Synchrotron | ENG | 361 KB | |
Application Report - Digital Communication in Steel-Plate Manufacturing | ENG | 470 KB |
Manuals | Language | File Type | File Size |
---|---|---|---|
Manual | ENG | 1729 KB |
Declaration of Conformity | Certificate No. | Language | File Type | File Size |
---|---|---|---|---|
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-2703B | ALL | 1036 KB | |
Declaration of Conformity for simple apparatus / Konformitätserklärung für einfache Betriebsmittel | DOC-2471 | ALL | 883 KB |
Variants | ||||||
---|---|---|---|---|---|---|
|
||||||
Specifications | ||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
RSS Info Service for PANOS Updates
Stay informed when a new software update of PANOS, the operating system for Ethernet-APL switches, is released: With our RSS Feed you will get an email notfication in your inbox immediately after an update has been released.