Datasheet excerpt: Technical data of
PMI120-F90-IE8-V15
General specifications |
Switching element function | Analog current output with PNP binary NO |
Object distance | 0.5 ... 3 mm , recommended: 2 mm |
Measuring range | 0 ... 120 mm |
Linearity range | 1 ... 119 mm |
Nominal ratings |
Operating voltage | 18 ... 30 V DC |
Reverse polarity protection | reverse polarity protected |
Linearity error | within measuring range: ± 0.8 mm within linearity range: ± 0.4 mm |
Repeat accuracy | ± 0.1 mm |
Resolution | 125 µm |
Temperature drift | ± 0.5 mm (-25 °C ... 70 °C) |
No-load supply current | ≤ 40 mA |
Operating voltage indicator | LED green |
Functional safety related parameters |
MTTFd | 270 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Switching output |
Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected |
Operating current | ≤ 100 mA |
Switching window | ± 1 mm |
Switching hysteresis | 0.4 mm |
Voltage drop | ≤ 3 V |
Short-circuit protection | pulsing |
Analog output |
Output type | 1 current output: 4 ... 20 mA |
Load resistor | ≤ 400 Ω |
Compliance with standards and directives |
Standard conformity | |
| Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 |
Approvals and certificates |
UL approval | cULus Listed, General Purpose, Class 2 Power Source |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Mechanical specifications |
Connection type | 5-pin, M12 x 1 connector |
Degree of protection | IP67 |
Material | |
| Housing | ABS |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) |
Dimensions | |
| Height | 41 mm |
| Width | 23 mm |
| Length | 142 mm |
Classifications
System | Classcode |
ECLASS 13.0 | 27274004 |
ECLASS 12.0 | 27274004 |
ECLASS 11.0 | 27270702 |
ECLASS 10.0.1 | 27270702 |
ECLASS 9.0 | 27270702 |
ECLASS 8.0 | 27270702 |
ECLASS 5.1 | 27270702 |
ETIM 9.0 | EC001852 |
ETIM 8.0 | EC001852 |
ETIM 7.0 | EC001852 |
ETIM 6.0 | EC001852 |
ETIM 5.0 | EC001852 |
UNSPSC 12.1 | 39121550 |
Details:
PMI120-F90-IE8-V15
Product Documentation:
PMI120-F90-IE8-V15
Design / Simulation:
PMI120-F90-IE8-V15
Approvals:
PMI120-F90-IE8-V15
Associated Products:
PMI120-F90-IE8-V15
Accessories |
|
|
|
Female cordset single-ended M12 straight A-coded, 5-pin, PVC cable greyfa |
|
|
|
|
Female cordset single-ended M12 angled A-coded, 5-pin, PVC cable greyfa |
|
|
|
|
Damping element for sensors of type F90, F112, and F166; side holefa |
|
|
|
|
Mounting bracket for mounting of F90 sensors, Material: Metal sheet (steel), zinc-platedfa |
|