|
| |
Product |
|
|
The product 'F.FB0.P**.A**.1.0.***.***.****' is now added to your watch list.
The product 'F.FB0.P**.A**.1.0.***.***.****' is already on your watch list.
|
4, 8 or 12 outputs Ex ia, Impact resistance enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Device coupler location: Zone 2 - high-power trunk Zone 1 - high-power trunk, Device coupler location [2]: Zone 1 - high-power trunk, Instrument location / spur protection: Zone 0 ... 1 - intrinsic safety, Function: Device coupler, Design / Mounting: Outside installationpa |
|
|
|
The product 'F.FB0.T**.***.1.0.***.***.****' is now added to your watch list.
The product 'F.FB0.T**.***.1.0.***.***.****' is already on your watch list.
|
FieldBarrier Junction Box, Brushed Stainless Steel, 4, 8 or 12 outputs Ex ia, Brushed enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Device coupler location: Zone 2 - high-power trunk Zone 1 - high-power trunk, Device coupler location [2]: Zone 1 - high-power trunk, Instrument location / spur protection: Zone 0 ... 1 - intrinsic safety, Function: Device coupler, Design / Mounting: Outside installationpa |
|
|
|
The product 'F.FB1.P14.A**.1.*.***.***.****' is now added to your watch list.
The product 'F.FB1.P14.A**.1.*.***.***.****' is already on your watch list.
|
8, 10, 12 outputs Ex ia, Impact resistance enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Device coupler location: Zone 2 - high-power trunk Zone 1 - high-power trunk, Device coupler location [2]: Zone 1 - high-power trunk, Instrument location / spur protection: Zone 0 ... 1 - intrinsic safety, Function: Device coupler, Design / Mounting: Outside installationpa |
|
|
|
The product 'F.FB1.T14.***.1.*.***.***.****' is now added to your watch list.
The product 'F.FB1.T14.***.1.*.***.***.****' is already on your watch list.
|
FieldBarrier Junction Box, Brushed Stainless Steel, 8, 10, 12 outputs Ex ia, Brushed enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Device coupler location: Zone 2 - high-power trunk Zone 1 - high-power trunk, Device coupler location [2]: Zone 1 - high-power trunk, Instrument location / spur protection: Zone 0 ... 1 - intrinsic safety, Function: Device coupler, Design / Mounting: Outside installationpa |
|
|
-
F2-JB-*.*
-
Field Junction Box
-
FieldConnex® Fieldbus
-
|
The product 'F2-JB-*.*' is now added to your watch list.
The product 'F2-JB-*.*' is already on your watch list.
|
FieldConnex® Fieldbus, Field junction box, stand-alone device in aluminum housing for field installation, 4 ... 8 outputs selectable, Installation in non-explosion hazardous area, Instruments in non-explosion hazardous area, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Supports FISCO and Entity, Europe, Device coupler location: non-explosion hazardous area, Instrument location / spur protection: non-explosion hazardous area, Function: Device coupler, Design / Mounting: Outside installationpa |
|
|
-
F2-JB-I*.*
-
Field Junction Box
-
FieldConnex® Fieldbus
-
|
The product 'F2-JB-I*.*' is now added to your watch list.
The product 'F2-JB-I*.*' is already on your watch list.
|
FieldConnex® Fieldbus, Field junction box, stand-alone device in aluminum housing for field installation, 4 ... 8 outputs Ex ia, ib, Installation in Zone 1/Div. 1, Instruments in Zone 0...1/Div. 1, Trunk and spurs intrinsically safe, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Europe, Device coupler location: Zone 1 - intrinsically safe trunk, Instrument location / spur protection: Zone 0 ... 1 - intrinsic safety, Function: Device coupler, Design / Mounting: Outside installationpa |
|
|
|
The product 'F2D0-FB-Ex4.*' is now added to your watch list.
The product 'F2D0-FB-Ex4.*' is already on your watch list.
|
FieldConnex® Fieldbus, Fieldbus barrier, stand-alone device in aluminum housing for field installation, 4 outputs Ex ia IIC, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, Short circuit current limitation per output, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Dust protection, International, Europe, USA, Canada, Device coupler location: Zone 2 - high-power trunk Zone 1 - high-power trunk Division 2 - high-power trunkpa |
|
|
|
The product 'R4D0-FB-IA*' is now added to your watch list.
The product 'R4D0-FB-IA*' is already on your watch list.
|
FieldConnex® Fieldbus, Fieldbus barrier, module for DIN rail mounting, 8 ... 12 outputs Ex ia IIC, FISCO and Entity, Advanced fault isolation and diagnostics at the spur, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Dust protection, International, Europe, USA, Device coupler location: Zone 2 - high-power trunk Zone 1 - high-power trunk Division 2 - high-power trunk Division 1 - high-power trunkpa |
|
|
|
The product 'RD0-FB-Ex4.*' is now added to your watch list.
The product 'RD0-FB-Ex4.*' is already on your watch list.
|
FieldConnex® Fieldbus, Fieldbus barrier, module for DIN rail mounting, 4 outputs Ex ia IIC, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, Short circuit current limitation per output, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Dust protection, International, Europe, USA, Canada, Device coupler location: Zone 2 - high-power trunk Zone 1 - high-power trunk Division 2 - high-power trunk Division 1 - high-power trunkpa |
|
|
| |