General specifications | ||
---|---|---|
Measuring method | A metal plate at the end of the probe, within the insulation, and the surroundings (e. g. the silo walls) combine to form the two electrodes of a capacitor. If the probe is covered or free of material, then the capacitance changes and the LCL switches. | |
Equipment architecture | The measuring system consists of: - the device - a supply point - the connected control systems, switching units, signalling systems (e. g. lamps, horns, PCS, PLC, etc.) |
|
Construction type | device with rod probe | |
Operating mode | MAX = maximum safety: The device switches if the probe is covered or if the supply voltage is disconnected in a safety-oriented manner (signal on alarm). example application: overspill protection MIN = minimum safety: The device switches if the probe is uncovered or if the supply voltage is disconnected in a safetyoriented manner (signal on alarm). example application: dry-running protection |
|
Series | LCL1 | |
Supply | ||
Rated voltage | electrical connection E5: 10.8 ... 45 V DC, short-term pulse on 55 V DC electrical connection WA: 20 ... 235 V AC, 50/60 Hz or 20 ... 55 V DC |
|
Current consumption | electrical connection E5: max. 30 mA, reverse-polarity-proof electrical connection WA: max. 130 mA |
|
Electrical specifications | ||
Surge protection | overvoltage category III | |
Input | ||
Measured variable | limit level (limit value) | |
Measuring range | dielectric constant ≥ 1.6 | |
Output | ||
Switch-on delay | correct switching after max. 1.5 s | |
Output signal | connection E5: switching PNP, Imax = 200 mA - overload and short circuit protection - residual voltage at transistor at Imax < 2.9 V connection WA: contact change-over, potential-free - Umax = 253 V - Imax = 4 A (AC) - Pmax = 1000 VA, cos φ = 1, Pmax = 500 VA, cos φ > 0.7 |
|
Signal on alarm | connection E5: < 100 µA connection WA: relay de-energized |
|
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2006 , EN 61326-2-3:2006 | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Electromagnetic compatibility | NE 21 | |
Degree of protection | IEC 60529:2001 | |
Vibration resistance | EN 60068-2-64 | |
Climate class | EN 60068, part 2-38 (test Z/AD) | |
Measurement accuracy | ||
Reference operating conditions | vessel type: plastic vessel, ambient temperature: 73 °F (23 °C, 296 K), medium temperature: 73 °F (23 °C, 296 K) medium pressure pe: 0 bar, medium: dielectric constant = 2.6, conductivity: < 1 µS sensitivity setting: C |
|
Hysteresis | horizontal 4 mm (0.16 inch), vertical 7 mm (0.28 inch) | |
Long-term drift | horizontal 3 mm (0.12 inch), vertical 6 mm (0.24 inch) | |
Influence of medium temperature | depending on the filling material | |
Switching time | approx. 0.5 s when covering and uncovering the sensor | |
Operating conditions | ||
Installation conditions | ||
Installation position | any position | |
Mounting location | The capacitive limit switch can be installed in silos made of different materials (e. g. metal, plastic, concrete). | |
Process conditions | ||
Process temperature | -40 ... 130 °C (-40 ... 266 °F) -40 ... 80 °C (-40 ... 176 °F) (Dust-Ex version) |
|
Medium pressure limits | -1 ... 25 bar |
|
State of aggregation | solids | |
Solid contents | ≤ ∅ 30 mm | |
Bulk density | ≤ 200 g/l | |
Ambient conditions | ||
Ambient temperature | -40 ... 80 °C (-40 ... 176 °F) -40 ... 60 °C (-40 ... 140 °F) (Dust-Ex version) |
|
Storage temperature | -40 ... 80 °C (-40 ... 176 °F) | |
Shock resistance | device with F34 housing: 7 J | |
Vibration resistance | a(RMS) = 50 m/s2, ASD = 1.25 (m/s2)2/Hz, f = 5 to 2000 Hz, t = 3 x 2 h | |
Mechanical specifications | ||
Degree of protection | IP66, NEMA 4 | |
Connection | gland M20 thread G1/2, NPT1/2 |
|
Material | F14 housing: polyester PBT-FR F34 housing F34: aluminum Probe: PPS GF40 |
|
Dimensions | max. ∅94 mm (3.7 inch), length 391 mm (15.4 inch) | |
Process connection | thread R1 acc. to EN 10226, BSPT, adapter for R1-1/2 and G1-1/2 see accessories thread NPT1 to ANSI B 1.20.1, adapter for NPT1-1/4 see accessories |
|
Data for application in connection with hazardous areas | ||
EU-type examination certificate | see instruction manuals (SI) | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-31:2009 | |
General information | ||
Supplementary documentation | technical information (TI) manuals, brief instructions (BA, KA) instruction manuals (SI) |
|
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Designation | - LCL-Z10 cover with sight glass for F14 housing - LCL-Z11 adapter for R1-1/2, EN 10226 - LCL-Z12 adapter for G1-1/2, DIN ISO 228 - LCL-Z13 adapter for NPT1-1/4, steel - LCL-Z15 adapter for NPT1-1/4, 1.4571 |
System | Classcode |
---|---|
ECLASS 13.0 | 27200503 |
ECLASS 12.0 | 27200503 |
ECLASS 11.0 | 27200503 |
ECLASS 10.0.1 | 27200503 |
ECLASS 9.0 | 27200503 |
ECLASS 8.0 | 27200503 |
ECLASS 5.1 | 27200503 |
ETIM 9.0 | EC001447 |
ETIM 8.0 | EC002993 |
ETIM 7.0 | EC002993 |
ETIM 6.0 | EC002993 |
ETIM 5.0 | EC001447 |
UNSPSC 12.1 | 41111950 |
The capacitive limit switch is designed for limit detection of light bulk solids, e. g. grain products, flour, milk powder, animal feed, cement, chalk or plaster.
Versions:
Device with 140 mm (5.5 inch) rod probe, for bulk solids
Relay output (potential-free change-over contact) with AC or DC connection
PNP output with 3-wire DC connection
Product information | Language | File Type | File Size |
---|---|---|---|
TI00287O, Technical information LCL* | ENG | 1024 KB | |
Brief Instructions | |||
KA00093O, brief instructions LCL1 / KA00093O, Kurzanleitung LCL1 | ALL | 2015 KB | |
KA00094O, brief instructions LCL1, factory settings / KA00094O, Kurzanleitung LCL1, Werkseinstellung | ALL | 173 KB | |
KA00098O, Brief instructions adapter R1-1/2, G1-1/2 / KA00098O, Kurzanleitung Adapter R1-1/2, G1-1/2 | ALL | 523 KB | |
Safety and Security Documentation | |||
SI00011O, Instruction manual LCL1 | ENG | 881 KB |
Certificates | Certificate No. | Language | File Type | File Size |
---|---|---|---|---|
Canada CSA | CoC 212978 | ALL | 251 KB | |
Europe DEKRA EXAM | DMT 01 ATEX E 122 | ALL | 973 KB | |
Europe DEKRA EXAM ATEX Category 1/3 D | DMT 01 ATEX E 122 | ALL | 764 KB | |
USA FM | CoC 3013716 | ALL | 52 KB | |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-2219C | ALL | 269 KB | |
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-2547B | ALL | 260 KB | |
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-2220B | ALL | 261 KB | |
Contamination Declaration | ||||
Contamination declaration / Kontaminationserklärung | ALL | 137 KB |