Serviceline Industrial Sensors
Serviceline Explosion Protection

IO-Link master ICE11-8IOL1-G60L-V1D

ICE11-8IOL1-G60L-V1D
  • 4x IO-Link ports, Class A and 4x IO-Link ports, Class B
  • Multiprotocol-compatible
  • M12 power connector, L-coded
  • Sturdy metallic housing
  • Web-based configuration
  • Extended temperature range

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  ICE11-8IOL1-G60L-V1D

Product Description
Ethernet IO-Link module with 4x Class A and 4x Class B IO-Link ports
General specifications
UL File NumberE223772
Indicators/operating means
LED indicationsee manual
Rotary switchSetting the fieldbus protocol
Electrical specifications
Rated operating voltage20 ... 30 V
Nominal voltage24 V DC (SELV/PELV)
Current consumptiontyp. 160 mA ± 20 % at nominal voltage
Current loading capacityMax. 2 x 16 A per module
max. 9 A via US
max. 9 A via UAUX
Interface
Interface typeIndustrial Ethernet
Physical M12, D-coded
ProtocolPROFINET IO , EtherNet/IP , EtherCAT® , CC-Link IE Field Basic , MODBUS TCP
Transfer rateFast Ethernet 10/100 Mbps , full duplex
Inputs/Outputs
Number/Type4 x IO-Link Class A (X1 - X4)
4 x IO-Link Class B (X5 - X8)
configurable as:
max. 8 IO-Link and 4 digital inputs/outputs + 4 digital outputs
max. 12 digital inputs and 4 digital outputs
max. 16 digital outputs
short-circuit protected
Sensor supplymax. 4 A per port (X1 - X8) via L+ (pin 1)
max. 6.5 A per port pair (X1/X2, X3/X4, X5/X6, X7/X8)
max. 5 A per port pair (X1/X2, X3/X4, X5/X6, X7/X8) for UL applications
Output currentmax. 500 mA per port (X1 - X8) via C/Q (Ch. A/pin 4)
max. 2 A per port (X1 - X8) via DO (Ch. B/pin 2)
max. 5 A total current X5 ... X8 via UAUX
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 55032
Standard conformity
Degree of protectionEN 60529:2000
Fieldbus standardType 1 according to IEC 61131-2
Shock resistanceEN 61131-2:2004
Approvals and certificates
UL approval
Maximum permissible operating currentmax. 9 A
Ambient conditions
Ambient temperature-40 ... 70 °C (-40 ... 158 °F)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Relative humiditymax. 95 %
Altitude0 ... 2000 m
Shock and impact resistance50 g, 11 ms, all axes
Vibration resistance15 g at 5 - 500 Hz
Pollution degree3
Mechanical specifications
Contact elementsPA
Degree of protectionIP65 / IP67 / IP69K
ConnectionPower Supply M12, L-coded
Fieldbus M12, D-coded
Inputs/Outputs M12, A-coded
Material
ContactsCuSn, gold-plated
CuNi, gold-plated
HousingDiecast zinc
SealFKM
Mass480 g
Tightening torque, fastening screws1 Nm
Tightening torque, cable gland0.5 Nm
Dimensions
Height200 mm
Width59.6 mm
Length21 mm
Construction typeField housing
Tightening torque of clamping screws0.5 Nm

Classifications

SystemClasscode
ECLASS 13.027242608
ECLASS 12.027242608
ECLASS 11.027242608
ECLASS 10.0.127242608
ECLASS 9.027242608
ECLASS 8.027242608
ECLASS 5.127242608
ETIM 9.0EC001597
ETIM 8.0EC001597
ETIM 7.0EC001597
ETIM 6.0EC001597
ETIM 5.0EC001597
UNSPSC 12.132151705

Details: ICE11-8IOL1-G60L-V1D

Function

The module is a multiprotocol fieldbus module with 4 x IO-Link ports Class A and 4 x IO-Link ports Class B according to IO-Link standard V1.1.3.

The G60L design in fully cast metal housing is resistant to mechanical damage and environmental influences. The G60L has protection class IP65/IP67.

The fieldbus module serves as an interface between the controller of a fieldbus system and the field level. Due to its multiprotocol capability, the fieldbus module supports the Ethernet communication protocols PROFINET, EtherNet/IP, EtherCAT, CC-Link, and MODBUS TCP.

An L-coded M12 connector plug used for supplying power enables a current rating of up to 2 x 16 A via U S and U AUX. The inputs and outputs are equipped with A-coded M12 connector plugs. Connection to the fieldbus is achieved using a D-coded M12 connector plug.

The communication protocols are configured either manually via a rotary switch or automatically. The diagnostics display status information for each channel via LEDs. An integrated web server enables access to the fieldbus module. Information regarding the status of the module is also displayed and network parameters such as the IP address and subnet mask can be configured.

Product Documentation: ICE11-8IOL1-G60L-V1D

Language Selection:
ManualsLanguageFile TypeFile Size
Manual ICE11-8IOL-G60L-V1DENGPDF11821 KB

Design / Simulation: ICE11-8IOL1-G60L-V1D

Language Selection:
CADLanguageFile TypeFile Size
CAD 3-D / CAD 3-DALLSTP8927 KB

Approvals: ICE11-8IOL1-G60L-V1D

Language Selection:
CertificatesCertificate No.LanguageFile TypeFile Size
Canada, USA ULCoC E223772 RptRef E223772-20220705ALLPDF340 KB
IO-Link Manufacturer DeclarationCERT-7407ALLPDF187 KB
Declaration of Conformity
EU-Declaration of conformityTDOC-7259AENGENGPDF196 KB
UK-Declaration of conformityTDOC-7260AENGENGPDF171 KB

Software: ICE11-8IOL1-G60L-V1D

Language Selection:
Device Description Files/DriversRelease InfoFile TypeFile Size
EtherCAT ESI Files / EtherCAT ESI Dateien08/2024ZIP38 KB
EtherNet/IP EDS Files / EtherNet/IP EDS Dateien06/2024ZIP24 KB
PROFINET GSDML Files / PROFINET GSDML Dateien07/2024ZIP112 KB
CC-Link CSPP Files / CC-Link CSPP Dateien09/2024ZIP53 KB
Simplified AOIs (Add On Instructions) for Rockwell Automation Studio 5000. Read and Write a single parameter on an ICE1, ICE2, ICE11 or Allen Bradley IO-Link masters / Inbetriebnahmedatei_a2.0 Dec 19, 2023ZIP56091 KB
Software Tools
Function Blocks (Add-on Instructions) for ICE11 IO-Link master using EtherNet/IP protocol. Loads the process data into port-specific tags. Allen Bradley PLC with Studio 5000 required. Description file also included. / Inbetriebnahmedatei_a6 / 2023ZIP58096 KB
IO-Link IODD Automatic Upload Tool / Software Tool_a12/2024ZIP12900 KB

Associated Products: ICE11-8IOL1-G60L-V1D

Accessories

Male connector M12 straight D-coded 4-pin, for cable diameter 5 - 8 mm, shielded, field-attachablefa
Cordset M12 socket straight to M12 plug straight L-coded, 5-pin, PUR cable grey, UL approvedfa
Y connection cable M12 plug straight A-coded 4-pin to 2x M12 socket straight A-coded 4-pin, 2x PUR cable weld spatter resistant black, UL approved, drag chain suitable, torsion resistantfa
Female connector M12 straight L-coded 5-pin, for cable diameter 8 - 13 mm, field-attachablefa
torque screwdriver (0.6 Nm)fa
plug-in cap M12fa
I/O hub with IO-Link interface for 10 digital inputs and 6 digital outputsfa
I/O hub with IO-Link interface for 16 digital inputs/outputsfa
Female cordset single-ended M12 straight L-coded, 5-pin, PUR cable grey, UL approvedfa
Blind plug for M12 socketsfa
Y connection cable M12 socket straight A-coded 5-pin to M12 plug straight A-coded 3-pin / M12 plug straight A-coded 5-pin, 2x PUR cable black, drag chain suitable, torsion resistantfa
IO-Link converter with analog output (current/voltage)fa
IO-Link converter with analog input (current/voltage)fa
I/O hub with IO-Link interfacefa
IO-Link converter with temperature input for RTD resistance temperature sensorsfa
IIoT Starter Kit

Connect your factory floor sensors to the cloud and start your digital transformation with the new IIoT starter kits.

Free Download: White Paper on TCP-Based Communication Protocols (PDF)

This free PDF white paper compares the different TCP-based communication protocols (AMQP, OPC UA, MQTT, REST API) that have found their way up and are considered the enablers of IIoT and Industry 4.0. Get your free download now!

IO-Link Master with OPC UA Interface

The ICE 2 and ICE3 IO-Link master series come with an OPC UA interface and a real-time fieldbus protocol, making them an ideal solution for cloud-based applications. Read more about possible scenarios in our blog.