Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Ladda ned datablad som PDF::
Utdrag ur datablad: Tekniska data för
WCS3B-LS221-U2
Product Description |
safeWCS / PUS read head, RS-485 interface, with RS-485 terminator, mounting position opposite to the direction of travel, position direction counting down |
General specifications |
Passage speed | ≤ 12.5 m/s |
Measuring length | max. 314.5 m |
Free tolerances to code rail | horizontal: 31 mm ( ± 15.5 mm ) vertical: 28 mm ( ± 14 mm ) |
Resolution | ± 0.4 mm (1,250 positions/m) |
Functional safety related parameters |
MTTFd | 198 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means |
Operation indicator | LED green: power on |
Data flow indicator | LED yellow: data communication active |
Error indicator | LED red flashing: read head outside of code rail solid on: internal diagnostic test failed |
Electrical specifications |
Operating voltage | 10 ... 30 V DC |
Power consumption | 2 VA |
Interface |
Interface type | RS 485 interface |
Data output code | binary code |
Protocol | 1 , 2 |
Transfer rate | 62.5 kBit/s |
Address | 1 |
Termination | with RS 485 termination |
Standard conformity |
Emitted interference | DIN EN 61000-6-4 , DIN EN 12015 |
Noise immunity | DIN EN 61000-6-2 , DIN EN 12016 |
Shock resistance | DIN EN 60068-2-27, half sine 30 g, 18 ms |
Vibration resistance | DIN EN 60068-2-6, sine, 5 g, 10 - 2000 Hz, 10 cycles |
Approvals and certificates |
CSA approval | cCSAus Certified, General Purpose Class 2 power source |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Operating temperature | 0 ... 60 °C (32 ... 140 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Relative humidity | 90 % , noncondensing |
Mechanical specifications |
Connection type | 5-pin, M12 x 1 connector |
Degree of protection | IP54 |
Material | |
| Housing | ABS , PC (Polycarbonate) |
Mass | 500 g |
General information |
Ordering information | Mounting plate included with delivery |
Classifications
System | Classcode |
ECLASS 13.0 | 27270918 |
ECLASS 12.0 | 27270918 |
ECLASS 11.0 | 27270701 |
ECLASS 10.0.1 | 27270701 |
ECLASS 9.0 | 27270701 |
ECLASS 8.0 | 27270701 |
ECLASS 5.1 | 27270701 |
ETIM 9.0 | EC001852 |
ETIM 8.0 | EC001852 |
ETIM 7.0 | EC001852 |
ETIM 6.0 | EC001852 |
ETIM 5.0 | EC001852 |
UNSPSC 12.1 | 41111945 |
Details:
WCS3B-LS221-U2
Product Documentation:
WCS3B-LS221-U2
Manuals | Language | File Type | File Size |
Manual | ENG | PDF | 10971 KB
|
Approvals:
WCS3B-LS221-U2
Associated Products:
WCS3B-LS221-U2
Kit |
|
|
|
Kit consisting of a safe evaluation unit with fieldbus connection (EtherCAT® with FSoE protocol) and two safeWCS/PUS read heads, FailSafe over EtherCAT® (FSoE), Certified up to SIL 3 according to IEC 61508 and up to PLe according to EN 13849-1, Safe evaluation unit with WCS3B-LS221-U1 and WCS3B-LS221-U2, Reliable evaluation of position and speedfa |
|
Accessories |
|
|
|
Transparent protective case and seal for WCS3B readerfa |
|
|
|
|
Mounting plate for reading heads WCS2 and WCS3, Universal mounting plate for all reading heads WCS2... and WCS3...fa |
|