Ladda ned datablad som PDF::
Utdrag ur datablad: Tekniska data för
50FY41-V4A-12-KIT
General specifications |
Switching function | Normally open (NO) |
Output type | PNP/NPN |
Rated operating distance | 2.5 mm at 0 mm offset, 1.3 mm at 3.5 mm offset, 0 mm at 4.0 mm offset |
Installation | non-flush |
Output polarity | DC |
Output type | 4-wire |
Nominal ratings |
Operating voltage | 10 ... 12 V |
Short-circuit protection | NO |
Voltage drop | 7 V @ 10 K load, 12 V supply |
Operating current | 0.5 mA |
Current consumption | 30 mA |
Compliance with standards and directives |
Standard conformity | |
| Standards | IEC 60947-5-2:2012 IEC 60947-5-3:2013 IEC 61236-3-1:2008 |
Approvals and certificates |
CE conformity | 2014/30/EU |
UL approval | cULus Listed, General Purpose |
Ambient conditions |
Ambient temperature | -40 ... 100 °C (-40 ... 212 °F) |
Mechanical specifications |
Connection type | cable PVC , 3.5 m |
Core cross section | 0.34 mm2 |
Housing material | 316 stainless steel |
Sensing face | 316 stainless steel |
Degree of protection | IP69K |
Dimensions | |
| Width | 39 mm |
| Depth | 12.7 mm |
| Length | 39 mm |
Note | Only approved for use with FYQLA1-140R-3 and KE5D2-6H/2R-S Use only with actuator 52FY31-V4A |
Classifications
System | Classcode |
ECLASS 13.0 | 27274301 |
ECLASS 12.0 | 27274301 |
ECLASS 11.0 | 27270104 |
ECLASS 10.0.1 | 27270104 |
ECLASS 9.0 | 27270104 |
ECLASS 8.0 | 27270104 |
ECLASS 5.1 | 27270104 |
ETIM 9.0 | EC002544 |
ETIM 8.0 | EC002544 |
ETIM 7.0 | EC002544 |
ETIM 6.0 | EC002544 |
ETIM 5.0 | EC002544 |
UNSPSC 12.1 | 39121550 |
Details:
50FY41-V4A-12-KIT
Design / Simulation:
50FY41-V4A-12-KIT
Approvals:
50FY41-V4A-12-KIT
Associated Products:
50FY41-V4A-12-KIT
Accessory of |
|
|
|
fa |
|
Matching System Components |
|
|
|
24 V AC/DC supply, 6 monitored inputs, DIN rail mountable, Dual output relay contacts, Internal relay monitoringfa |
|