Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Ladda ned datablad som PDF::
Utdrag ur datablad: Tekniska data för
NDP20-FP-V1
Product Description |
Inductive transmitter system |
General specifications |
Installation | non-flush |
Transfer distance | 0 ... 20 mm |
Compliance with standards and directives |
Directive conformity | |
| EMC Directive 89/336/EEC | EN 61000-6-2:2001, EN 61000-6-4:2001, EN 50295:1999 |
Standard conformity | |
| Standards | EN IEC 60947-5-2 |
Approvals and certificates |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature | 0 ... 50 °C (32 ... 122 °F) |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
Mechanical specifications |
Housing material | PBT |
Sensing face | PBT |
Housing base | PBT |
Degree of protection | IP67 |
Installation | screw mounting |
| Spacing to metal walls | ≥ 150 mm |
| Security zone | ≥ 150 mm x 25 mm |
Dimensions | |
| Height | 80 mm |
| Width | 80 mm |
| Length | 40 mm |
General information |
Note | Maximum cable length between WIS module and WIS transmitter must not exceed 5 m. |
Classifications
System | Classcode |
ECLASS 13.0 | 27274090 |
ECLASS 12.0 | 27274090 |
ECLASS 11.0 | 27270190 |
ECLASS 10.0.1 | 27270190 |
ECLASS 9.0 | 27270190 |
ECLASS 8.0 | 27270190 |
ECLASS 5.1 | 27270190 |
ETIM 9.0 | EC002714 |
ETIM 8.0 | EC002714 |
ETIM 7.0 | EC002714 |
ETIM 6.0 | EC002714 |
ETIM 5.0 | EC002714 |
UNSPSC 12.1 | 39121550 |
Details:
NDP20-FP-V1
Design / Simulation:
NDP20-FP-V1
Associated Products:
NDP20-FP-V1
Matching System Components |
|
|
|
fa |
|