Serviceline Industrial Sensors
Serviceline Explosion Protection

Segment Protector Junction Box F.SPE.T**.A**.1.0.***.***.****

F.SPE.T**.A**.1.0.***.***.****
  • Connection of Ex d certified devices
  • Brushed enclosure, IP66
  • Configurable cable entries for trunk and spurs
  • International approvals
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • Installation in Zone 1

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Ladda ned datablad som PDF::


Utdrag ur datablad: Tekniska data för  F.SPE.T**.A**.1.0.***.***.****

Product Description
Segment Protector Junction Box, Brushed Stainless Steel
General specifications
Design / MountingOutside installation
Installed componentsSegment Protector R-SP-E12
For technical data on installed electronic component see data sheet.
Conformity
Degree of protectionEN 60529
Impact resistanceEN 60079-0
Ambient conditions
Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Relative humidity< 75 % (annual mean)
< 95 % (30 d/year), no moisture condensation
Impact resistance7J
Mechanical specifications
Enclosure coverHinged door with captive retaining screws
Degree of protectionIP66
Cable entrycable gland and stopping plug options see separate table
Material
HousingStainless steel 1.4404 / AISI 316L
Surfacebrushed
SealSilicone, fire-resistant, one piece, foamed
Material thicknessenclosure body, enclosure cover, mounting plate: 1.5 mm
Dimensions(W x H x D)
300 x 230 x 160 mm (1 x R-SP-E12)
480 x 380 x 220 mm (2 x R-SP-E12)
Mountingthru-holes Ø 7 mm
Groundinggrounding bolt M6 , brass, nickel-plated
Data for application in connection with hazardous areas
EU-type examination certificatePTB 07 ATEX 1061 X (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com
MarkingEx-Hexagon II 2G Ex db eb mb IIC T4 Gb
Ex-Hexagon II 2D Ex tb IIIC T135°C Db
Note: The marking is based on the maximum value and can be reduced depending on the selected options accordingly.
Directive conformity
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-1:2014+AC:2018 , EN IEC 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN 60079-18:2015+Cor.2018 , EN 60079-31:2014
International approvals
IECEx approvalIECEx PTB 07.0036 X , suitable Junction Box on request
INMETRO approvalTÜV 13.1143
General information
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027242610
ECLASS 12.027242610
ECLASS 11.027242610
ECLASS 10.0.127242610
ECLASS 9.027242610
ECLASS 8.027242610
ECLASS 5.127242601
ETIM 9.0EC001601
ETIM 8.0EC001601
ETIM 7.0EC001601
ETIM 6.0EC001601
ETIM 5.0EC001604
UNSPSC 12.139121008

Details: F.SPE.T**.A**.1.0.***.***.****

Informative Literature: F.SPE.T**.A**.1.0.***.***.****

Language Selection:
LiteratureLanguageFile TypeFile Size
Application Report - Controlling and Monitoring liquid Helium at the Deutsches Elektronen-SynchrotronENGPDF361 KB
Application Report - Digital Communication in Steel-Plate ManufacturingENGPDF470 KB

Product Documentation: F.SPE.T**.A**.1.0.***.***.****

Language Selection:
Safety and Security DocumentationLanguageFile TypeFile Size
ManualSWEPDF149 KB
Manuals
ManualENGPDF967 KB

Approvals: F.SPE.T**.A**.1.0.***.***.****

Language Selection:
CertificatesCert No.LanguageFile TypeFile Size
Europe PTB ATEX Category 2 G ATEX Category 2 DPTB 07 ATEX 1061 XALLPDF500 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-3149CALLPDF132 KB

Associated Products: F.SPE.T**.A**.1.0.***.***.****

Matching System Components

FieldConnex® Fieldbus, Segment protector, junction box for fieldbus with short-circuit protection, Field junction box, module for DIN rail mounting, 12 increased safety outputs (Ex e), Short circuit current limitation per output, Segment Protector in Zone 1/Div. 2, Instruments in Zone 1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Europe, Device coupler location: Zone 1 - high-power trunk, Instrument location / spur protection: Zone 1 - increased safetypa

Ethernet-APL möjliggör kontinuerlig kommunikation över alla hierarkiska nivåer. Läs mer om den banbrytande tekniken …

RSS Info Service for PANOS Updates

Stay informed when a new software update of PANOS, the operating system for Ethernet-APL switches, is released: With our RSS Feed you will get an email notfication in your inbox immediately after an update has been released.

Från beslut till planering, installation och driftsättning till drift och underhåll: Upptäck hur du får ut det mesta av din fältbussinfrastruktur …