Ladda ned datablad som PDF::
Utdrag ur datablad: Tekniska data för
DK10-LAS-54/76/110/124
Product Description |
Print mark contrast sensor, 10 m detection range, red laser light, laser class 2, light/dark on, sensitivity adjuster, push-pull output, M12 plug |
General specifications |
Effective detection range | 0 ... 10 m |
Reflector distance | 0 ... 10 m |
Threshold detection range | 12 m |
Reference target | reflector C110-2 |
Light source | laser diode |
Light type | modulated visible red light |
Laser nominal ratings | |
| Note | LASER LIGHT , DO NOT STARE INTO BEAM |
| Laser class | 2 |
| Wave length | 650 nm |
| Beam divergence | < 1.5 mrad |
| Pulse length | 1.5 µs |
| Repetition rate | 108.7 kHz |
| max. pulse energy | 2.1 nJ |
Light spot representation | approx. 10 mm at a distance of 10 m |
Ambient light limit | |
| Continuous light | 40000 Lux |
Functional safety related parameters |
MTTFd | 550 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 60 % |
Indicators/operating means |
Function indicator | LED yellow: lights up if receiver is lit (light on), lights up if receiver is not lit (dark on) |
Control elements | Light-on/dark-on changeover switch, sensitivity adjuster |
Electrical specifications |
Operating voltage | 10 ... 30 V DC |
Ripple | 10 % |
No-load supply current | ≤ 55 mA |
Input |
Test input | emitter deactivation with +Ub |
Output |
Switching type | light/dark on switchable |
Signal output | Push-pull output, short-circuit protected, reverse polarity protected |
Switching voltage | PNP: UB - 2.5 V / NPN: URest 1.5 V |
Switching current | max. 200 mA |
Switching frequency | 16.5 kHz |
Response time | 30 µs |
Conformity |
Product standard | EN 60947-5-2 |
Laser safety | IEC 60825-1:2007 |
Compliance with standards and directives |
Standard conformity | |
| Shock and impact resistance | IEC / EN 60068. half-sine, 40 g in each X, Y and Z directions |
| Vibration resistance | IEC / EN 60068-2-6. Sinus. 10 -150 Hz, 5 g in each X, Y and Z directions |
Approvals and certificates |
UL approval | cULus Listed , Class 2 power source |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature | -10 ... 50 °C (14 ... 122 °F) |
Storage temperature | -20 ... 75 °C (-4 ... 167 °F) |
Mechanical specifications |
Degree of protection | IP67 |
Connection | 5-pin, M12 x 1 connector |
Material | |
| Housing | PC (glass-fiber-reinforced Makrolon) |
| Optical face | glass |
Mass | 200 g |
Dimensions | |
| Height | 85.6 mm |
| Width | 33 mm |
| Depth | 60.8 mm |
Classifications
System | Classcode |
ECLASS 13.0 | 27270906 |
ECLASS 12.0 | 27270906 |
ECLASS 11.0 | 27270906 |
ECLASS 10.0.1 | 27270906 |
ECLASS 9.0 | 27270906 |
ECLASS 8.0 | 27270906 |
ECLASS 5.1 | 27270906 |
ETIM 9.0 | EC001820 |
ETIM 8.0 | EC001820 |
ETIM 7.0 | EC001820 |
ETIM 6.0 | EC001820 |
ETIM 5.0 | EC001820 |
UNSPSC 12.1 | 39121528 |
Details:
DK10-LAS-54/76/110/124
Product Documentation:
DK10-LAS-54/76/110/124
Design / Simulation:
DK10-LAS-54/76/110/124
Approvals:
DK10-LAS-54/76/110/124
Associated Products:
DK10-LAS-54/76/110/124
Accessories |
|
|
|
Female cordset single-ended M12 straight A-coded, 5-pin, PVC cable greyfa |
|
|
|
|
Female cordset single-ended M12 angled A-coded, 5-pin, PVC cable greyfa |
|
|
|
|
Right-Angled Mounting Bracketfa |
|
|
|
|
Flat Mounting Bracketfa |
|