RFID read/write device IUT-F190-B40-2V1D-FR1-01

IUT-F190-B40-2V1D-FR1-01
  • Compact, high-performance UHF RFID read/write device for medium detection ranges
  • Rugged housing for harsh industrial environments
  • Switchable antenna polarization and multi-tag reading
  • Clearly visible LED status indicator
  • Integrated 2-port switch enables line or ring topology
  • Simple operation and configuration via integrated web server
  • OPC UA Server and AutoID Companion Specification enable standardized communication
  • Easy integration into IT systems via REST API

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Ladda ned datablad som PDF::


Utdrag ur datablad: Tekniska data för  IUT-F190-B40-2V1D-FR1-01

Product Description
UHF RFID read/write device, Europe
General specifications
Operating frequency865 … 868 MHz: EU, Turkey
Transmission licenses for other countries on request
Emitted power3 ... 1000 mW ERP adjustable
MTBF55 a (Operation at +40 °C)
Indicators/operating means
LED greenPower on
LED yellowRead/write operation successful
LED blueTransmission mode
LED Link/Trafficgreen: network connection
yellow: flashes in rhythm with the transmitted data
Electrical specifications
Rated operating voltage20 ... 30 V DC , PELV
Ripple≤ 10 % at 30 V DC
Current consumption≤ 500 mA
Power consumption≤ 10 W
Surge protectioncategory 2
Interface 1
Physical Ethernet
ProtocolHTTP (REST API)
OPC UA (AutoID Companion Specification)
EtherNet/IP
PROFINET IO
Transfer rate10 MBit/s or 100 MBit/s
Interface 2
Physical Ethernet
ProtocolHTTP (REST API)
OPC UA (AutoID Companion Specification)
EtherNet/IP
PROFINET IO
Transfer rate10 MBit/s or 100 MBit/s
Directive conformity
Radio equipment
Directive 2014/53/EUEN 301489-1
EN 301489-3
EN 302208
EN 62368-1
EN 62311
EN 50364
RoHS
Directive 2011/65/EU (RoHS)IEC/EN 63000
Standard conformity
Degree of protectionEN 60529
RFIDISO/IEC 18000-63
Ambient conditions
ClassificationEnvironmental condition A (controlled environment)
Ambient temperature-20 ... 70 °C (-4 ... 158 °F) (Operation with nontransmission periods, adjustable)
-20 ... 50 °C (-4 ... 122 °F) (Continuous transmission mode)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Pollution degree2
Mechanical specifications
Degree of protectionIP67
ConnectionPower supply: M12 connector
Protective earth: M4 earthing screw
Ethernet: M12 plug connection
Material
HousingPA 6.6
Basediecast aluminum
Mass770 g
Dimensions
Height63 mm
Width112 mm
Length114 mm

Classifications

SystemClasscode
ECLASS 13.027280401
ECLASS 12.027280401
ECLASS 11.027280401
ECLASS 10.0.127280401
ECLASS 9.027280401
ECLASS 8.027280401
ECLASS 5.127280401
ETIM 9.0EC002998
ETIM 8.0EC002998
ETIM 7.0EC002998
ETIM 6.0EC002998
ETIM 5.0EC002998
UNSPSC 12.143211710

Details: IUT-F190-B40-2V1D-FR1-01

Product Documentation: IUT-F190-B40-2V1D-FR1-01

Language Selection:
ManualsLanguageFile TypeFile Size
Manual IUT-F190-B40-2V1D-*ENGPDF10841 KB
Manual Read / Write Ranges and Passing Speeds RFIDENGPDF3640 KB

Design / Simulation: IUT-F190-B40-2V1D-FR1-01

Language Selection:
CADLanguageFile TypeFile Size
CAD 3-D / CAD 3-DALLSTP4300 KB
CAD Portal / CAD PortalALLLINK---

Approvals: IUT-F190-B40-2V1D-FR1-01

Language Selection:
CertificatesCert No.LanguageFile TypeFile Size
ODVA Ethernet/IP12148.01ALLPDF126 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-3816BALLPDF110 KB
Simplified EU Declaration of Conformity / Vereinfachte EU-Konformitätserklärung   ALLPDF61 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)DOC-7038ALLPDF109 KB

Software: IUT-F190-B40-2V1D-FR1-01

Language Selection:
Device Description Files/DriversRelease InfoFile TypeFile Size
EDS / EDS2023-12ZIP17 KB
GSD / GSD2024-04ZIP125 KB
Function block TIA Portal (S7-1200/1500) for the RFID station IUT-F190-B40-2V1D (Profinet) when using the Expert Mode. / Funktionsbaustein TIA Portal (S7-1200/1500) für die RFID-Station IUT-F190-B40-2V1D (Profinet) bei der Verwendung des Expert Modes.V1.0ZIP16587 KB
Function blocks TIA Portal (S7-1200/1500) for the RFID station IUT-F190-B40-2V1D (Profinet) when using the Easy Mode. / Funktionsbausteine TIA Portal (S7-1200/1500) für die RFID-Station IUT-F190-B40-2V1D (Profinet) bei der Verwendung des Easy Modes.V1.1ZIP14269 KB
Function blocks TIA Portal (S7-300/400) for the RFID station IUT-F190-B40-2V1D (Profinet) when using the Easy Mode. / Funktionsbausteine TIA Portal (S7-300/400) für die RFID-Station IUT-F190-B40-2V1D (Profinet) bei der Verwendung des Easy ModesV1.1ZIP14824 KB
Function blocks TIA Portal (S7-300/400) for the RFID station IUT-F190-B40-2V1D (Profinet) when using the Expert Mode. / Funktionsbausteine TIA Portal (S7-300/400) für die RFID-Station IUT-F190-B40-2V1D (Profinet) bei der Verwendung des Expert ModesV1.0ZIP10059 KB
OpenAPI Specification / OpenAPI-SpezifikationLINK---
Firmware
Firmware / FirmwareV2.1.2ZIP1975 KB
Software Tools
Add-On instructions for Rockwell Automation Studio 5000 software. For parameterization and read/write functionality on IUT-...-B40, IUT-...IO and IQT3-...-IO Readers / Software Tool_a2.0 Dec 19, 2023ZIP227840 KB

Associated Products: IUT-F190-B40-2V1D-FR1-01

Accessories
RFID Transponderfa
RFID Transponderfa
RFID Transponderfa
RFID Transponderfa
Tag for standard applicationsfa
Tag for paint shop applicationsfa
Tag for autoclave applicationsfa
Mounting bracket for wall mountingfa
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mmfa
Female cordset single-ended M12 straight A-coded, 5-pin, PUR cable grey, shieldedfa
Ethernet bus cable M12 plug straight D-coded to RJ45 Ethernet-coded, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
RFID Read/Write Device IUT-F190-B40 with Industrial Ethernet Interface and REST API

Get to know the new IUT-F190-B40, which is designed for medium detection ranges, and can be quickly and easily integrated into OT and IT systems …

Visit the RFID Hub

Visit our "RFID Hub"—this special website is a knowledge base for RFID. Get answers on frequently asked questions and learn about typical RFID applications …