Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Ladda ned datablad som PDF::
Utdrag ur datablad: Tekniska data för
6100-MP-LPP-*
Product Description |
6100 series purge and pressurization system pressure sensor |
General specifications |
Series | 6100 Series |
System | Ex pxb Purge |
Hazardous environment | gas |
Electrical specifications |
Connection | |
| Power | Intrinsically safe connection to the 6100 control unit |
| Signal | Bus connection to 6100 control unit |
| Connection | M12 connector, 4-pin, max length 30 m |
Indicators/settings |
LED indication | power: green |
Pneumatic parameters |
Maximum pressure | 0 ... 25 mbar (0 ... 10 in wc) pressure range |
Directive conformity |
Electromagnetic compatibility | |
| Directive 2014/30/EU | EN 61326-1:2013 |
RoHS | |
| Directive 2011/65/EU (RoHS) | EN IEC 63000:2018 |
Ambient conditions |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Storage temperature | -30 ... 80 °C (-22 ... 176 °F) |
Relative humidity | 5 ... 95 %, noncondensing |
Vibration resistance | 10 ... 100 Hz , 1 g, all axes |
Impact resistance | 30 g, 11 ms, all axes |
Mechanical specifications |
Material | 5052 anodized aluminum, 6061T6 anodized aluminum |
Installation | - any orientation to enclosure
- not gravity dependent
|
Mass | approx. 0.5 kg (1.1 lb) |
Dimensions | 57.2 mm x 81.1 mm x 82.6 mm (2.3" x 3.2" x 3.3") |
| Height | 146 mm |
| Width | 127.5 mm |
| Depth | 82.5 mm |
Mounting | 1 1/2" NPT knockout (50.8 mm (2") hole) with sealing washer and nut |
Data for application in connection with hazardous areas |
Certificate | CML 19 ATEX 1425X |
| Marking | II 2 G Ex ib [pxb Gb] IIC T4 Gb |
Directive conformity | |
| Directive 2014/34/EU | EN IEC 60079-0:2018 EN 60079-2:2014 EN 60079-11:2012 |
International approvals |
IECEx approval | IECEx CML 19.0156X Ex ib [pxb Gb] IIC T4 Gb |
General information |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. Supplemental Standards : EN 61010-1:2010 |
Classifications
System | Classcode |
ECLASS 13.0 | 27180591 |
ECLASS 12.0 | 27180591 |
ECLASS 11.0 | 27180591 |
ECLASS 10.0.1 | 27292190 |
ECLASS 9.0 | 27292190 |
ECLASS 8.0 | 27292190 |
ECLASS 5.1 | 40050501 |
ETIM 9.0 | EC000243 |
ETIM 8.0 | EC000243 |
ETIM 7.0 | EC000243 |
ETIM 6.0 | EC000243 |
ETIM 5.0 | EC000243 |
UNSPSC 12.1 | 39121303 |
Details:
6100-MP-LPP-*
Product Documentation:
6100-MP-LPP-*
Safety and Security Documentation | Language | File Type | File Size |
Manual | SWE | PDF | 164 KB
|
Manuals |
Manual | ENG | PDF | 5218 KB
|
Design / Simulation:
6100-MP-LPP-*
Associated Products:
6100-MP-LPP-*
Accessory of |
|
|
|
pa |
|