* Pepperl+Fuchs makes every effort to provide an answer that is helpful and relevant to you. Your question is typically answered in one business day. Occasionally, an answer is delayed. In these cases, we are often researching your question, conferring with colleagues, or may route your question to another Pepperl+Fuchs location. You will be notified via e-mail regarding the status of your question.
Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
Datasheet excerpt: Technical data of
IUT-F191-IO-V1-FR2-03
Product Description
UHF RFID read/write device with IO-Link, China
General specifications
Operating frequency
920.5 … 924.5 MHz: China Transmission licenses for other countries on request
Emitted power
3 … 100 mW ERP adjustable
UL File Number
E468231
MTBF
127 a (Operation at +40 °C)
Indicators/operating means
LED green/red
Solid green: Ready for operation, no IO-Link communication Flashing green (1 Hz): IO-Link operation
LED yellow
Read/write operation successful
LED blue
Transmission mode
Electrical specifications
Operating voltage
18 ... 30 V DC (IO-Link) ; Class 2, LEC or LPS
Current consumption
≤ 90 mA ( at 24 V DC )
Interface
Interface type
IO-Link
IO-Link revision
1.1
Device profile
Identification and Diagnosis - I&D
Process data
Input 32 Byte Output 32 Byte
Vendor ID
1 (0x0001)
Device ID
4194819 (0x400203)
Data transfer rate
COM3 (230.4 kbits/s)
Min. cycle time
4 ms
SIO mode support
no
Compatible master port type
Class A Class B
Standard conformity
Degree of protection
EN 60529
Communication interface
IEC 61131-9 / IO-Link V1.1.3
RFID
ISO/IEC 18000-63
Approvals and certificates
UL approval
UL 61010-1 Protection class is not included in the UL approval. The protection class is tested by Pepperl+Fuchs SE.
SRRC approval
CMIIT ID: 2023DJ4252
Ambient conditions
Ambient temperature
-25 ... 70 °C (-13 ... 158 °F) (Operation with nontransmission periods) -25 ... 60 °C (-13 ... 140 °F) (Continuous transmission mode)
Storage temperature
-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Degree of protection
IP67
Connection
connector M12 x 1
Material
Housing
PA 6.6
Base
Aluminum
Mass
700 g
Dimensions
Height
47 mm
Width
165 mm
Length
165 mm
Classifications
System
Classcode
ECLASS 13.0
27280401
ECLASS 12.0
27280401
ECLASS 11.0
27280401
ECLASS 10.0.1
27280401
ECLASS 9.0
27280401
ECLASS 8.0
27280401
ECLASS 5.1
27280401
ETIM 9.0
EC002998
ETIM 8.0
EC002998
ETIM 7.0
EC002998
ETIM 6.0
EC002998
ETIM 5.0
EC002998
UNSPSC 12.1
43211710
Details:
IUT-F191-IO-V1-FR2-03
Function
The read/write device operates in the UHF frequency range and is optimized for use in industrial applications involving shorter distances. The device reads and writes passive tags acc. to EPC Generation 2 (
ISO/IEC 18000-63). The read/write device is compliant with the relevant transmission regulations.
Wide range of options supported for filtering data. The read/write device has an IO-Link interface and is connected via a M12 connector. The user can monitor the status of the read/write device using the integrated LEDs.
The read/write device has a typical detection range of around 1 meter; this range is determined by the tag used and can be adjusted by configuring the transmission power. Other influencing factors include the setup and installation of the specific application and the surrounding materials, particularly metal. The read and write distances for the relevant tag, which are detailed separately, have been established in a test laboratory under ideal conditions. For the actual read and write distances under real conditions, the combination of read/write device and tag must be tested in the desired application.
Register for an introduction to RFID technology training session with our Product Manager. Sessions are one-on-one and last around an hour. All skill levels are welcome.
Visit our "RFID Hub"—this special website is a knowledge base for RFID. Get answers on frequently asked questions and learn about typical RFID applications …