Frequency Converter with Direction and Synchronization Monitor
2-channel isolated barrier, Universal usage at different power supplies, Dry contact or NAMUR inputs, Input frequency 1 mHz ... 1 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Configurable by PACTware or keypad, Line fault detection (LFD), Housing width: 40 mm, Number of channels: 2-channel, Trip relay, Start-up override, Frequency conversion, Rotation direction monitoring, Rotation speed monitoring, Synchronization monitoringpa
Frequency Converter with Direction and Synchronization Monitor
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz ... 1 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Configurable by PACTware or keypad, Line fault detection (LFD), Housing width: 40 mm, Number of channels: 2-channel, Trip relay, Start-up override, Frequency conversion, Rotation direction monitoring, Rotation speed monitoring, Synchronization monitoring, Slip monitoringpa
Frequency current converter with trip value and direction of rotation
106744
Forældede produkter: 2 inputs, Control circuit EEx ia IIC, Input frequency 1 mHz ... 5 kHz, Analog output 0/4 mA ... 20 mA, Measuring range parameterisable, 2 relay outputs, 2 electronic outputs, isolated, Each output individually parameterisable as trip value, serially switched output, direction of rotation, synchronization monitoring or error message output, Start-up override, Lead breakage (LB) and short-circuit (SC) monitoring, Debounce filter, Parameterization via PC or control panel (optional)pa
Frequency Converter with Direction and Synchronization Monitor
188375
Forældede produkter: 2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz ... 1 kHz, Current output 0/4 mA ... 20 mA, Relay and transistor output, Start-up override, Configurable by PACTware or keypad, Line fault detection (LFD), Housing width: 40 mm, Number of channels: 2-channel, Trip relay, Rated voltage: 20 ... 30 V DCpa
Frequency current converter with trip value and direction of rotation
049539
Forældede produkter: 2 inputs, Control circuit EEx ia IIC, Input frequency 1 mHz ... 5 kHz, Analog output 0/4 mA ... 20 mA, Measuring range parameterisable, 2 relay outputs, 2 electronic outputs, isolated, Each output individually parameterisable as trip value, serially switched output, direction of rotation, synchronization monitoring or error message output, Start-up override, Lead breakage (LB) and short-circuit (SC) monitoring, Debounce filter, Parameterization via PC or control panel (optional)pa
Frequency current converter with trip value monitoring as well as rotation direction and slip signalling
132918
Forældede produkter: 2 frequency inputs, 2 control inputs, 2 relay outputs, 2 electronic outputs, isolated, Analog output 0/4 mA ... 20 mA, Lead monitoring (can be deactivated), Parameterization via keypad, Input frequency 0.001 Hz ... 1 kHz (slip monitor function 10 Hz ... 1 kHz), Housing width: 40 mm, Rated voltage: 20 ... 90 V DC / 48 ... 253 V ACpa
Frequency Converter with Direction and Synchronization Monitor
188377
Forældede produkter: 2-channel isolated barrier, Universal usage at different power supplies, Dry contact or NAMUR inputs, Input frequency 1 mHz ... 1 kHz, Current output 0/4 mA ... 20 mA, Relay and transistor output, Start-up override, Configurable by PACTware or keypad, Line fault detection (LFD), Housing width: 40 mm, Number of channels: 2-channel, Trip relay, Rated voltage: 20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hzpa