Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Hent hele databladet som PDF:
Uddrag af datablad: Tekniske data for
PSU-IDMx61-BC-N0-N0
Produkt beskrivelse |
Power supply for IDM* non-Ex base station and charger |
General specifications |
Type | Power supply |
Supply |
Input voltage | 100 ... 240 V AC rated input voltage , 90 ... 264 V AC operating range |
Input current | max. 0.4 A max. input power: 13.37 W |
Input frequency | 50/60 Hz |
Power consumption | (no-loading) max. 0.1 W |
Output |
Output rated operating current | ≤ 2 A |
Voltage | 5 V DC |
Power | 10 W |
Ambient conditions |
Operating temperature | 0 ... 25 °C (32 ... 77 °F) |
Storage temperature | -20 ... 80 °C (-4 ... 176 °F) |
Relative humidity | 90 % non-condensing |
Mechanical specifications |
Degree of protection | IP20 |
Cable | international pin, DC plug type 4 x 1.7 x 12 mm (fork and groove), polarity: center "+" US plug, EU plug, UK plug |
| Length | 1.83 m |
Mass | 100 g |
Dimensions | 79 mm x 41 mm x 40 mm (W x H x D) |
International approvals |
UL approval | UL 60950-1 (IT Equipment) |
General information |
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
Classifications
System | Classcode |
ECLASS 13.0 | 19209090 |
ECLASS 12.0 | 19209290 |
ECLASS 11.0 | 19209290 |
ECLASS 10.0.1 | 19209290 |
ECLASS 9.0 | 19209290 |
ECLASS 8.0 | 19209290 |
ECLASS 5.1 | 27242392 |
ETIM 9.0 | EC002542 |
ETIM 8.0 | EC002542 |
ETIM 7.0 | EC002542 |
ETIM 6.0 | EC002542 |
ETIM 5.0 | EC002542 |
UNSPSC 12.1 | 39121004 |
Details:
PSU-IDMx61-BC-N0-N0
Tilhørende produkter:
PSU-IDMx61-BC-N0-N0
Accessory of |
|
|
|
Base station for IDM-Z1-* (Non-hazardous areas), Base/charging station for IDM-Z1-x61-M-* Bluetooth® handheld readers, Bluetooth interfacepa |
|
|
|
|
Charging station for IDM-Z1-* without Bluetooth® functionality (Non-hazardous area), Charging station for IDM-Z1-x61-M-* Bluetooth handheld readers, For use in non-hazardous area onlypa |
|
Accessories |
|
|
|
Serial extension cable for IDM-Zx-* handheld barcode readers, Serial extension cable, Suitable for Zone 1/21 and Zone 2/22 (ATEX & IECEx), M12 female socket to M12 male connector, Protocol: serialpa |
|
|
|
|
Serial extension cable for IDM-Zx-* handheld barcode readers, Serial extension cable, Suitable for Zone 1/21 and Zone 2/22 (ATEX & IECEx), M12 female socket to M12 male connector, Protocol: serialpa |
|
|
|
|
Serial extension cable for IDM-Zx-* handheld barcode readers, Serial extension cable, Suitable for Zone 1/21 and Zone 2/22 (ATEX & IECEx), M12 female socket to M12 male connector, Protocol: serialpa |
|
|
|
|
Serial extension cable for IDM-Zx-* handheld barcode readers, Serial extension cable, Suitable for Zone 1/21 and Zone 2/22 (ATEX & IECEx), M12 female socket to M12 male connector, Protocol: serialpa |
|