Support Industrielle sensorer
Support Explosion Protection

Mounting bracket MH-F90

MH-F90

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Hent hele databladet som PDF:


Uddrag af datablad: Tekniske data for   MH-F90

Produkt beskrivelse
Mounting bracket for mounting of F90 sensors
Mechanical specifications
MaterialMetal sheet (steel), zinc-plated
Note2 pieces, included with delivery

Classifications

SystemClasscode
ECLASS 13.027273701
ECLASS 12.027273701
ECLASS 11.027273701
ECLASS 10.0.127273701
ECLASS 9.027273701
ECLASS 8.027279202
ECLASS 5.127279202
ETIM 9.0EC003015
ETIM 8.0EC003015
ETIM 7.0EC003015
ETIM 6.0EC003015
ETIM 5.0EC003015
UNSPSC 12.131162301

Details: MH-F90

Tilhørende produkter: MH-F90

Accessory of

Parameterization and diagnosis via IO-Link, Measuring range 0 ... 80 mm, Parameterisable measuring range, Analog current or voltage output, programmable, 2 Push-pull outputs, Switching element function: Analog current or voltage output, programmable
2 switch outputs, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC
(13 ... 30 V when analog voltage output is parameterized), Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4)fa

Parameterization and diagnosis via IO-Link, Measuring range 0 ... 40 mm, Parameterisable measuring range, Analog current or voltage output, programmable, 2 Push-pull outputs, Switching element function: Analog current or voltage output, programmable
2 switch outputs, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC
(13 ... 30 V when analog voltage output is parameterized), Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4)fa

Parameterization and diagnosis via IO-Link, Measuring range 0 ... 120 mm, Parameterisable measuring range, Analog current or voltage output, programmable, 2 Push-pull outputs, Switching element function: Analog current or voltage output, programmable
2 switch outputs, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC
(13 ... 30 V when analog voltage output is parameterized), Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4)fa
Analog output 0 V ... 10 V/4 mA ... 20 mA, Measuring range 0 ... 120 mm, Switching element function: analog, current or voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: 1 current output: 4 ... 20 mA
1 voltage output: 0 ... 10 V, UL approval: cULus Listed, General Purpose, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: 4-pin, M12 x 1 connector, Degree of protection: IP67fa
Analog output 0 V ... 10 V/4 mA ... 20 mA, Measuring range 0 ... 104 mm, Switching element function: analog, current or voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: 1 current output: 4 ... 20 mA
1 voltage output: 0 ... 10 V, UL approval: cULus Listed, General Purpose, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: 4-pin, M12 x 1 connector, Degree of protection: IP67fa
Analog output 0 V ... 10 V/4 mA ... 20 mA, Measuring range 0 ... 80 mm, Switching element function: analog, current or voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: 1 current output: 4 ... 20 mA
1 voltage output: 0 ... 10 V, UL approval: cULus Listed, General Purpose, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: 4-pin, M12 x 1 connector, Degree of protection: IP67fa
Analog output 4 mA ... 20 mA, Adjustable switch points, Measuring range 0 ... 80 mm, Switching element function: Analog current output with PNP binary NO, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected, Output type: 1 current output: 4 ... 20 mA, UL approval: cULus Listed, General Purpose, Class 2 Power Sourcefa
Parameterization and diagnosis via IO-Link, Measuring range 0 ... 80 mm, Parameterisable measuring range, Analog current or voltage output, programmable, Switching element function: Analog current or voltage output, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC
(13 ... 30 V when analog voltage output is parameterized), Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4), Output type: current output 4-20 mA voltage output 0 - 5 V DC 0 ... 10 V DC , programmablefa
Analog output 4 mA ... 20 mA, Adjustable switch points, Measuring range 0 ... 104 mm, Switching element function: Analog current output with PNP binary NO, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected, Output type: 1 current output: 4 ... 20 mA, UL approval: cULus Listed, General Purpose, Class 2 Power Sourcefa
Measuring range 0 ... 40 mm, Analog output 0 ... 10 V DC, Switching element function: analog voltage output, Output polarity: DC, Operating voltage: 12 ... 30 V DC, Type of voltage: DC, Output type: voltage output 0 ... 10 V DC, UL approval: cULus Listed, Class 2 Power Source, Type 1 enclosure, Connection type: 5-pin, M12 x 1 connector, Degree of protection: IP67 / IP69K, Housing: PBT, stainless steel 1.4571 , brass, nickel-platedfa
Parameterization and diagnosis via IO-Link, Measuring range 0 ... 120 mm, Parameterisable measuring range, 3 Push-pull outputs, Switch points programmable via IO-Link, Switching element function: 3 switch outputs, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC, Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4), Output type: 3 push-pull outputs (can be parameterized), short-circuit-proof, reverse polarity protection ,
overvoltage protectedfa
Parameterization and diagnosis via IO-Link, Measuring range 0 ... 120 mm, Parameterisable measuring range, Analog current or voltage output, programmable, 2 Push-pull outputs, Switching element function: Analog current or voltage output, programmable
2 switch outputs, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC
(13 ... 30 V when analog voltage output is parameterized), Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4)fa
Parameterization and diagnosis via IO-Link, Measuring range 0 ... 40 mm, Parameterisable measuring range, Analog current or voltage output, programmable, Switching element function: Analog current or voltage output, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC
(13 ... 30 V when analog voltage output is parameterized), Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4), Output type: current output 4-20 mA voltage output 0 - 5 V DC 0 ... 10 V DC , programmablefa
Parameterization and diagnosis via IO-Link, Measuring range 0 ... 120 mm, Parameterisable measuring range, Analog current or voltage output, programmable, Switching element function: Analog current or voltage output, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC
(13 ... 30 V when analog voltage output is parameterized), Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4), Output type: current output 4-20 mA voltage output 0 - 5 V DC 0 ... 10 V DC , programmablefa
Analog output 4 mA ... 20 mA, Adjustable switch points, Measuring range 0 ... 120 mm, Switching element function: Analog current output with PNP binary NO, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected, Output type: 1 current output: 4 ... 20 mA, UL approval: cULus Listed, General Purpose, Class 2 Power Sourcefa
Parameterization and diagnosis via IO-Link, Measuring range 0 ... 40 mm, Parameterisable measuring range, 3 Push-pull outputs, Switch points programmable via IO-Link, Switching element function: 3 switch outputs, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC, Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4), Output type: 3 push-pull outputs (can be parameterized), short-circuit-proof, reverse polarity protection ,
overvoltage protectedfa
Parameterization and diagnosis via IO-Link, Measuring range 0 ... 80 mm, Parameterisable measuring range, 3 Push-pull outputs, Switch points programmable via IO-Link, Switching element function: 3 switch outputs, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC, Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4), Output type: 3 push-pull outputs (can be parameterized), short-circuit-proof, reverse polarity protection ,
overvoltage protectedfa