Uddrag af datablad: Tekniske data for
ENA36IL-R***-SSI
General specifications |
Detection type | magnetic sampling |
Device type | Absolute rotary encoder |
Linearity error | ≤ ± 0.1 ° |
UL File Number | E223176 "For use in NFPA 79 Applications only" , if UL marking is marked on the product. |
Functional safety related parameters |
MTTFd | 700 a at 40 °C |
Mission Time (TM) | 20 a |
L10 | 1035 E+8 revolutions at 19/44 N axial/radial shaft load |
Diagnostic Coverage (DC) | 0 % |
Electrical specifications |
Operating voltage | 4.75 ... 30 V DC |
Power consumption | ≤ 1 W |
Time delay before availability | < 450 ms |
Output code | Gray code, binary code |
Code course (counting direction) | adjustable |
Interface |
Interface type | SSI |
Resolution | |
| Single turn | up to 16 Bit |
| Multiturn | up to 16 Bit |
| Overall resolution | up to 32 Bit |
Transfer rate | 0.1 ... 2 MBit/s |
Cycle time | < 100 µs |
Standard conformity | RS 422 |
Input 1 |
Input type | Selection of counting direction (cw/ccw) |
Signal voltage | |
| High | 4.75 V ... UB (cw descending) |
| Low | 0 ... 2 V or unconnected (cw ascending) |
Input current | < 6 mA |
Switch-on delay | < 250 ms |
Input 2 |
Input type | zero-set (PRESET 1) with falling edge |
Signal voltage | |
| High | 4.75 V ... UB |
| Low | 0 ... 2 V |
Input current | < 6 mA |
Signal duration | min. 1.1 s |
Connection |
Connector | M12 connector, 8-pin |
Cable | ∅6 mm, 4 x 2 x 0.14 mm2 |
Standard conformity |
Degree of protection | DIN EN 60529, IP65 or IP54 |
Climatic testing | DIN EN 60068-2-3, no moisture condensation |
Emitted interference | EN 61000-6-4:2007 |
Noise immunity | EN 61000-6-2:2005 |
Shock resistance | DIN EN 60068-2-27, 200 g, 6 ms |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 1000 Hz |
Approvals and certificates |
UL approval | cULus Listed, General Purpose, Class 2 Power Source , if UL marking is marked on the product. |
Ambient conditions |
Operating temperature | cable, movable installation: -5 ... 70 °C (23 ... 158 °F), cable, fixed installation: -30 ... 70 °C (-22 ... 158 °F) connector models: -40 ... 85 °C (-40 ... 185 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Relative humidity | 98 % , no moisture condensation |
Mechanical specifications |
Material | |
| Housing | nickel-plated steel |
| Flange | Aluminum |
| Shaft | Stainless steel |
Mass | approx. 150 g |
Rotational speed | max. 12000 min -1 |
Moment of inertia | 30 gcm2 |
Starting torque | < 3 Ncm |
Shaft load | |
| Axial | 19 N |
| Radial | 44 N |
| Axial offset | ± 0.3 mm static |
| Radial offset | ± 0.5 mm static |
Dimensions | |
| Diameter | 36.5 mm |
Classifications
System | Classcode |
ECLASS 13.0 | 27270502 |
ECLASS 12.0 | 27270502 |
ECLASS 11.0 | 27270502 |
ECLASS 10.0.1 | 27270502 |
ECLASS 9.0 | 27270502 |
ECLASS 8.0 | 27270502 |
ECLASS 5.1 | 27270502 |
ETIM 9.0 | EC001486 |
ETIM 8.0 | EC001486 |
ETIM 7.0 | EC001486 |
ETIM 6.0 | EC001486 |
ETIM 5.0 | EC001486 |
UNSPSC 12.1 | 39121527 |
Details:
ENA36IL-R***-SSI
Product Documentation:
ENA36IL-R***-SSI
Design / Simulation:
ENA36IL-R***-SSI
Approvals:
ENA36IL-R***-SSI
Tilhørende produkter:
ENA36IL-R***-SSI
Accessories |
|
|
|
Female cordset single-ended M12 straight A-coded, 8-pin, PUR cable grey, shieldedfa |
|
|
|
|
Female connector M12 straight A-coded 8-pin, for cable diameter 5 - 8 mm, shielded, field-attachablefa |
|
|
|
|
Cordset M12 socket straight to M12 plug straight A-coded, 8-pin, PUR cable grey, shieldedfa |
|
|
|
|
Female cordset single-ended M12 straight A-coded, 8-pin, PUR cable grey, shieldedfa |
|
|
|
|
Female connector M12 angled A-coded 8-pin, for cable diameter 5 - 8 mm, shielded, field-attachablefa |
|